Assessment of the production of medical isotopes using the Monte Carlo code FLUKA: Simulations against experimental measurements

  • The Monte Carlo code FLUKA is used to simulate the production of a number of positron emitting radionuclides, ¹⁸F, ¹³N, ⁹⁴Tc, ⁴⁴Sc, ⁶⁸Ga, ⁸⁶Y, ⁸⁹Zr, ⁵²Mn, ⁶¹Cu and ⁵⁵Co, on a small medical cyclotron with a proton beam energy of 13 MeV. Experimental data collected at the TR13 cyclotron at TRIUMF agree within a factor of 0.6 ± 0.4 with the directly simulated data, except for the production of ⁵⁵Co, where the simulation underestimates the experiment by a factor of 3.4 ± 0.4. The experimental data also agree within a factor of 0.8 ± 0.6 with the convolution of simulated proton fluence and cross sections from literature. Overall, this confirms the applicability of FLUKA to simulate radionuclide production at 13 MeV proton beam energy.

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Angelo Infantino, Elisabeth PaulßenORCiD, Domiziano Mostacci, Paul Schaffer, Michael Trinczek, Cornelia Hoehr
DOI:https://doi.org/10.1016/j.nimb.2015.10.067
ISSN:1872-9584
Parent Title (English):Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Publisher:Elsevier
Place of publication:Amsterdam
Document Type:Article
Language:English
Year of Completion:2016
Date of the Publication (Server):2018/03/07
Volume:366
First Page:117
Last Page:123
Link:http://doi.org/10.1016/j.nimb.2015.10.067
Zugriffsart:bezahl
Institutes:FH Aachen / Fachbereich Chemie und Biotechnologie
collections:Verlag / Elsevier