• Treffer 17 von 59
Zurück zur Trefferliste

Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate

  • Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future.

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar
Metadaten
Verfasserangaben:Chang-Hoon Choi, Tim Felder, Jörg Felder, Lutz Tellmann, Suk-Min Hong, Hans-Peter Wegener, N Jon Shah, Karl Ziemons
DOI:https://doi.org/10.1088/1361-6560/ab87f8
ISSN:0031-9155
Titel des übergeordneten Werkes (Englisch):Physics in Medicine & Biology
Verlag:IOP
Verlagsort:Bristol
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Erscheinungsjahr:2020
Datum der Publikation (Server):28.07.2020
Jahrgang:65
Ausgabe / Heft:11
Link:https://doi.org/10.1088/1361-6560/ab87f8
Zugriffsart:weltweit
Fachbereiche und Einrichtungen:FH Aachen / Fachbereich Medizintechnik und Technomathematik
collections:Verlag / IOP
Open Access / Hybrid
Lizenz (Deutsch):License LogoCreative Commons - Namensnennung