Filtern
Erscheinungsjahr
- 2009 (35) (entfernen)
Institut
- Fachbereich Energietechnik (35) (entfernen)
Dokumenttyp
- Wissenschaftlicher Artikel (15)
- Konferenzveröffentlichung (8)
- Teil eines Buches (Kapitel) (5)
- Buch (Monographie) (3)
- Dissertation (2)
- Diplomarbeit (1)
- Vortrag (1)
Schlagworte
- Blitzschutz (4)
- Blitzeinschlag (1)
- Fernerkundung (1)
- Infrarot-Reflexions-Absorptions-Spektroskopie (1)
- Infrarotmesstechnik (1)
- Lightning protection (1)
- MIR-Spektroskopie (1)
- Quantenkaskadenlaser (1)
- Speckle (1)
- Trinitrotol (1)
In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.
Das Ziel der vorliegenden Arbeit ist die Specklereduktion bei der Infrarotlaser-gestützten abbildenden Ferndetektion von TNT-Oberflächenkontaminationen. Für die Detektion wird die Probenoberfläche mit einem abstimmbaren Quantenkaskadenlaser bei verschiedenen Wellenzahlen im Spektralbereich von 1340cm-1 bis 1380cm-1 bestrahlt, während eine Infrarot-Kamera Bilder der bestrahlten Fläche aufzeichnet. Diese Bilder werden dann so verarbeitet, dass im Ausgabebild die chemisch spezifische TNT-Absorption durch eine Änderung der Helligkeit örtlich aufgelöst erkennbar werden. Da kohärente Strahlung, welche beispielsweise an optisch rauen Oberflächen reflektiert wird, aufgrund der stochastischen Verteilung der Oberflächenrautiefe mit der einfallenden Strahlung lateral unterschiedlich interferiert, entsteht ein „Rauschen“ in der aufgezeichneten Strahlungsleistungsverteilung, das sog. Speckle-Phänomen. Die Empfindlichkeit der oben skizzierten Lasergestützten Messtechnik wird im Wesentlichen durch diesen Effekt limitiert. Um die durch Laserspeckles verursachten Rauschanteile zu reduzieren, gibt es verschiedene Möglichkeiten. Durch Reduktion von zeitlicher und räumlicher Kohärenz der Strahlung wird deren Interferenzfähigkeit reduziert und durch Variieren des Specklemusters während einer Bildaufzeichnung führen Mittelungen unkorrelierter Rauschanteile zu einer Specklekontrastreduktion. Letztere Möglichkeit resultiert daraus, dass Laserspeckles statistisch durch die Familie der Gammaverteilungen beschrieben werden können. Demnach verbessert sich das Signal-zu-Rausch-Verhältnis mit der Anzahl gemittelter, unkorrelierter Rauschmuster proportional zur Wurzel dieser Anzahl. Ein im MIR-Spektralbereich umsetzbarer Ansatz, der all diese Möglichkeiten berücksichtigt, wurde bereits 1971 von Lowenthal und Joyeaux vorgeschlagen und im Rahmen der vorliegenden Arbeit für den infraroten Spektralbereich adaptiert. Dazu wird die Strahlung mit zwei CVD-Diamant-Wafern moduliert; ein Wafer ist dabei stationär und der andere rotiert mit ca. 70Hz. In der vorliegenden Arbeit konnte mit diesem Ansatz eine Verbesserung des Signal-zu-Rausch-Verhältnisses in der betrachteten Strahlungsleistungs¬verteilung von ursprünglich 3 auf etwa 45 erzielt werden. So konnten erstmals TNT-Kontaminationen von bis zu 10µg/cm² in einem Abstand von 5m abbildend nachgewiesen werden. Dies entspricht der Kontamination durch einen mit TNT leicht verunreinigten Fingerabdruck.
Die Einleitung zur Norm DIN EN 62305-3 beschreibt klar und ein - deutig: Der vorliegende Teil der IEC 62305 behandelt den Schutz von baulichen Anlagen gegen materielle Schäden und den Schutz von Personen gegen Verletzungen durch Berührungs- und Schrittspannungen. Als das wesentlichste und effektivste Mittel zum Schutz von baulichen Anlagen gegen materielle Schäden gilt das Blitz - schutzsystem (LPS).
[Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate.
8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke können durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verfügbarkeit und Sicherheit gefährdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. Höchstspannungsnetzes und nicht in das darüber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschränkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung übertragen.
A new solar desalination system with heat recovery for decentralised drinking water production
(2009)
In diesem Artikel werden zunächst einleitend der Gasmarkt Deutschland und der sich daraus ergebende Speicherbedarf skizziert. Folgend wird auf verschiedene Speichernutzen aus betriebswirtschaftlicher Perspektive eingegangen und die in diesem Artikel vorgestellten Bewertungsverfahren einleitend beschrieben. In diesem Artikel werden stochastische Optimierungsmethoden aufgegriffen, die sowohl eine Bewertung der Speicher gegenüber einem Spotpreis, als auch gegenüber einer gesamten Forwardcurve ermöglichen. Hierzu werden zunächst Modelle zur Beschreibung der Marktpreise vorgestellt und anhand empirischer Daten kalibriert. Dann wird eine beispielhafte Speicherscheibe zunächst auf Basis der LeastSquareMonteCarloTechnik gegenüber dem stochastischen mehrfaktoriellen Spotpreismodell bewertet. Hieran schließt sich die Vorstellung der Bewertung sowie des Hedgings gegenüber der Forwardcurve an. Abschließend erfolgt eine vergleichende Gegenüberstellung beider Verfahren.
Risiken des Handels
(2009)
In order for traditional masonry to stay a competitive building material in seismically active regions there is an urgent demand for modern, deformation-based verification procedures which exploit the nonlinear load bearing reserves. The Capacity Spectrum Method (CSM) is a widely accepted design approach in the field of reinforced concrete and steel construction. It compares the seismic action with the load-bearing capacity of the building considering nonlinear material behavior with its post-peak capacity. The bearing capacity of the building is calculated iteratively using single wall capacity curves. This paper presents a new approach for the bilinear approximation of single wall capacity curves in the style of EC6/EC8 respectively FEMA 306/FEMA 356 based on recent shear wall test results of the European Collective-Research Project “ESECMaSE”. The application of the CSM to masonry structures by using bilinear approximations of capacity curves as input is demonstrated on the example of a typical German residential home.