Filtern
Erscheinungsjahr
Institut
- Fachbereich Medizintechnik und Technomathematik (2080) (entfernen)
Sprache
- Englisch (1693)
- Deutsch (373)
- Russisch (13)
- Niederländisch (1)
Dokumenttyp
- Wissenschaftlicher Artikel (1594)
- Konferenzveröffentlichung (243)
- Buch (Monographie) (97)
- Teil eines Buches (Kapitel) (62)
- Dissertation (28)
- Patent (17)
- Bericht (15)
- Sonstiges (9)
- Habilitation (4)
- Vorlesung (3)
- Preprint (3)
- Konferenz: Meeting Abstract (1)
- Lehrmaterial (1)
- Rezension (1)
- Vortrag (1)
- Arbeitspapier (1)
Schlagworte
- Biosensor (25)
- Finite-Elemente-Methode (16)
- CAD (15)
- civil engineering (14)
- Bauingenieurwesen (13)
- Einspielen <Werkstoff> (13)
- shakedown analysis (9)
- FEM (6)
- Limit analysis (6)
- Shakedown analysis (6)
Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals
(2010)
High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli.
Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study.
Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System.
Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala.
Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia.
A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests.
Es wird ein Brennstoffeinspritzsystem für Brennkraftmaschinen vorgeschlagen, bei dem ein definiertes Teil eines fest vorgegebenen Brennstoffvolumens durch die Druckerhöhung innerhalb einer brennstoffeinschließenden Kammer eine definierte Brennstoffmenge über jeweils ein Rückschlagventil abgespritzt wird. Ein elektronisches Steuergerät berechnet die Dauer und/oder Intensität und gegebenenfalls die Impulsfolge eines zum Beispiel zur Verdampfung einer bestimmten Brennstoffmenge erforderlichen Laserimpulses. Das System kann für Ein- oder Mehrstelleinspritzung Verwendung finden.
Effectiveness of the edge-based smoothed finite element method applied to soft biological tissues
(2012)
Die Erfindung betrifft eine Vorrichtung zur Messung biomedizinischer Daten eines Probanden, mit einem Messsystem zur Erhebung der Daten sowie einer ersten Hardware-Komponente zur Aufzeichnung der Daten. In einer Verbindungsleitung zur Übertragung der Daten vom Messsystem zur ersten Hardware-Komponente zur Aufzeichnung der Daten ist erfindungsgemäss ein Mittel zur galvanischen Auftrennung der Daten angeordnet. Auf diese Weise ist wenigstens die Duplizierung der Daten für Datenverarbeitungszwecke gewährleistet. Die auf diese Weise verarbeiteten Daten werden für ein Verfahren zur Echtzeit-Stimulation eines Probanden genutzt.
Die vorliegende Erfindung betrifft eine Vorrichtung zum Halten eines lebenden Objektes bei physiologischen Messungen mit einem Basiselement und Mitteln zum Arretieren des lebenden Objektes, die atraumatische Ohrenhalter sowie ein Mundstück aufweisen, das mit einer Aussparung für die Zähne des Lebewesens versehen ist, mit einem Masseanteil von wenigstens 95% an glasfaserverstärktem Kunststoff.