Refine
Year of publication
Document Type
- Article (132)
- Conference Proceeding (62)
- Part of a Book (13)
- Book (4)
- Lecture (3)
- Other (3)
- Report (2)
- Doctoral Thesis (1)
- Patent (1)
- Review (1)
Keywords
- Finite-Elemente-Methode (16)
- Einspielen <Werkstoff> (13)
- shakedown analysis (9)
- FEM (6)
- Limit analysis (6)
- Shakedown analysis (6)
- limit analysis (6)
- Einspielanalyse (4)
- Shakedown (4)
- Technische Mechanik (4)
- Traglast (4)
- Traglastanalyse (4)
- shakedown (4)
- ratchetting (3)
- Analytischer Zulaessigkeitsnachweis (2)
- Biocomposites (2)
- Bruchmechanik (2)
- Druckbeanspruchung (2)
- Druckbehälter (2)
- Druckbelastung (2)
- Einspiel-Analyse (2)
- Fehlerstellen (2)
- Natural fibres (2)
- Polymer-matrix composites (2)
- Ratcheting (2)
- Rohr (2)
- Rohrbruch (2)
- Stahl (2)
- Stress concentrations (2)
- burst pressure (2)
- burst tests (2)
- damage (2)
- flaw (2)
- limit load (2)
- load limit (2)
- pipes (2)
- tension–torsion loading (2)
- vessels (2)
- Alternating plasticity (1)
- Anastomose (1)
- Anastomosis (1)
- Anastomotic leakage (1)
- Arthosetherapie (1)
- Aufschlagversuch (1)
- Autolysis (1)
- Axialbelastung (1)
- Axially cracked pipe (1)
- Basis Reduktion (1)
- Basis reduction (1)
- Bicharakteristikenverfahren (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Bladder (1)
- Bone sawing (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Chance constrained programming (1)
- Collagen fibrils (1)
- Computational biomechanics (1)
- Connective tissues (1)
- Constitutive model (1)
- Convex optimization (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Deformation (1)
- Design-by-analysis (1)
- Discontinuous fractures (1)
- Distorsion des oberen Sprunggelenks (1)
- Druckgeräte (1)
- Drug simulation (1)
- ES-FEM (1)
- Einspiel-Kriterium (1)
- Einspielen (1)
- Elastizität (1)
- Elastodynamik (1)
- Elastostatics (1)
- Electromechanical modeling (1)
- End-to-end colorectal anastomosis (1)
- Evolution of damage (1)
- Exact Ilyushin yield surface (1)
- Extension fracture (1)
- Extension strain criterion (1)
- Extracellular matrix (ECM) (1)
- FEM-Programm (1)
- FEM-computation (1)
- FS-FEM (1)
- Festkörper (1)
- Finite element analysis (1)
- Finite element analysis (FEA) (1)
- Finite element method (1)
- Finite element modelling (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Fließgrenze (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Fußball (1)
- Global and local collapse (1)
- Gonarthrose (1)
- Grenzwertberechnung (1)
- Growth modelling (1)
- Heart tissue culture (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Ion channels (1)
- Kinematics (1)
- Kinetics (1)
- Kniegelenkarthrose (1)
- Knochen (1)
- Knochenbildung (1)
- Knochenchirugie (1)
- Knochendichte (1)
- LISA (1)
- Liver (1)
- MBST (1)
- Materialermüdung (1)
- Mechanical simulation (1)
- Mechanical stability (1)
- Mechanics (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Multimode failure (1)
- Muscle fibers (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- Non-linear optimization (1)
- Non-parallel fissures (1)
- PFM (1)
- Passive stretching (1)
- Pelvic floor dysfunction (1)
- Pelvic muscle (1)
- Pharmacology (1)
- Plastizität (1)
- Pressure loaded crack-face (1)
- Progressive plastic deformation (1)
- Random variable (1)
- Ratchetting (1)
- Reconstruction (1)
- Reliability analysis (1)
- Reliability of structures (1)
- S-FEM (1)
- Schienbeinschoner (1)
- Schwammknochen (1)
- Sensitivity (1)
- Shakedown criterion (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Statics (1)
- Stochastic programming (1)
- Strukturanalyse (1)
- Surgical staplers (1)
- Tapered ends (1)
- Temperaturabhängigkeit (1)
- Torsion (1)
- Torsionsbelastung (1)
- Tragfähigkeit (1)
- Uniaxial compression test (1)
- Ureter (1)
- Variable height stapler design (1)
- Wellen (1)
- Wolff's Law (1)
- Wolffsches Gesetz (1)
- Zug-Druck Belastung (1)
- Zug-Druck-Beanspruchung (1)
- Zug-Druck-Belastung (1)
- alternierend Verformbarkeit (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- arthrosis therapy (1)
- biaxial tensile experiment (1)
- bicharacteristics (1)
- bone density (1)
- bone structure (1)
- cancellous bone (1)
- chance constrained programming (1)
- constitutive modeling (1)
- dental trauma (1)
- design-by-analysis (1)
- difficult airway (1)
- direct method (1)
- distorted element (1)
- double-lumen tube intubation (1)
- elastic solids (1)
- fatigue analyses (1)
- fibulare Bandruptur (1)
- finite element analysis (1)
- fortschreitende plastische Deformation (1)
- gonarthrosis (1)
- hiPS cardiomyocytes (1)
- hyperelastic (1)
- konvexe Optimierung (1)
- limit and shakedown analysis (1)
- linear kinematic hardening (1)
- load carrying capacity (1)
- lower bound theorem (1)
- material shakedown (1)
- mechanical waves (1)
- non-simplex S-FEM elements (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- plastic deformation (1)
- probabilistic fracture mechanics (1)
- reliability (1)
- reliability analysis (1)
- reliability of structures (1)
- rupture of the fibular ligament (1)
- second-order reliability method (1)
- shakedown analyses (1)
- smooth muscle contraction (1)
- stochastic programming (1)
- strain energy function (1)
- thermal ratcheting (1)
- training simulator (1)
- videolaryngoscopy (1)
- virgin passive (1)
- virtual reality (1)
- viscoelasticity (1)
- yield stress (1)
Background
Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far.
Methods
10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed.
Findings
Compared to the control group, the work to fracture could be increased by 33.2%. The fracture force increased by 19.9%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry.
Interpretation
The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results.