Refine
Year of publication
Document Type
- Conference Proceeding (130)
- Article (77)
- Lecture (5)
- Working Paper (4)
- Poster (1)
- Talk (1)
Language
- English (218) (remove)
Has Fulltext
- yes (218) (remove)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (12)
- Einspielen <Werkstoff> (10)
- CAD (8)
- civil engineering (8)
- Bauingenieurwesen (7)
- Blitzschutz (6)
- FEM (6)
- Clusterion (5)
- shakedown analysis (5)
- Air purification (4)
- Hämoglobin (4)
- Limit analysis (4)
- Luftreiniger (4)
- Plasmacluster ion technology (4)
- Raumluft (4)
- Shakedown analysis (4)
- Sonde (4)
- Telekommunikationsmarkt (4)
- Einspielanalyse (3)
Institute
- Fachbereich Medizintechnik und Technomathematik (123)
- IfB - Institut für Bioengineering (60)
- Fachbereich Energietechnik (27)
- INB - Institut für Nano- und Biotechnologien (23)
- Fachbereich Maschinenbau und Mechatronik (17)
- Fachbereich Luft- und Raumfahrttechnik (14)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Wirtschaftswissenschaften (11)
- Fachbereich Bauingenieurwesen (7)
- Fachbereich Elektrotechnik und Informationstechnik (7)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (5)
- ECSM European Center for Sustainable Mobility (4)
- Nowum-Energy (4)
- Solar-Institut Jülich (4)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Gestaltung (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.