Refine
Year of publication
Document Type
- Article (5586) (remove)
Language
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- biosensors (4)
- field-effect sensor (4)
- frequency mixing magnetic detection (4)
- Blitzschutz (3)
- CellDrum (3)
- Heparin (3)
- Label-free detection (3)
- additive manufacturing (3)
- capacitive field-effect sensor (3)
- hydrogen peroxide (3)
- magnetic nanoparticles (3)
Institute
- Fachbereich Medizintechnik und Technomathematik (1578)
- Fachbereich Wirtschaftswissenschaften (687)
- Fachbereich Elektrotechnik und Informationstechnik (625)
- Fachbereich Energietechnik (608)
- Fachbereich Chemie und Biotechnologie (597)
- INB - Institut für Nano- und Biotechnologien (540)
- Fachbereich Maschinenbau und Mechatronik (483)
- IfB - Institut für Bioengineering (448)
- Fachbereich Luft- und Raumfahrttechnik (373)
- Fachbereich Bauingenieurwesen (330)
- Solar-Institut Jülich (107)
- Fachbereich Architektur (79)
- Fachbereich Gestaltung (58)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (42)
- ECSM European Center for Sustainable Mobility (39)
- Nowum-Energy (34)
- Sonstiges (23)
- Institut fuer Angewandte Polymerchemie (20)
- Freshman Institute (18)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (16)
Electrolyte-insulator-semiconductor capacitors (EISCAP) belong to field-effect sensors having an attractive transducer architecture for constructing various biochemical sensors. In this study, a capacitive model of enzyme-modified EISCAPs has been developed and the impact of the surface coverage of immobilized enzymes on its capacitance-voltage and constant-capacitance characteristics was studied theoretically and experimentally. The used multicell arrangement enables a multiplexed electrochemical characterization of up to sixteen EISCAPs. Different enzyme coverages have been achieved by means of parallel electrical connection of bare and enzyme-covered single EISCAPs in diverse combinations. As predicted by the model, with increasing the enzyme coverage, both the shift of capacitance-voltage curves and the amplitude of the constant-capacitance signal increase, resulting in an enhancement of analyte sensitivity of the EISCAP biosensor. In addition, the capability of the multicell arrangement with multi-enzyme covered EISCAPs for sequentially detecting multianalytes (penicillin and urea) utilizing the enzymes penicillinase and urease has been experimentally demonstrated and discussed.