Refine
Year of publication
Document Type
- Article (122) (remove)
Has Fulltext
- yes (122) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- FEM (4)
- Finite-Elemente-Methode (4)
- Rapid Prototyping (4)
- Blitzschutz (3)
- 3D-Printing (2)
- Acyl-amino acids (2)
- Aminoacylase (2)
- Bacillaceae (2)
- Bauingenieurwesen (2)
- Biotechnological application (2)
- CAD (2)
- CFD (2)
- Capacitive field-effect sensor (2)
- Einspielanalyse (2)
- Hochschuldidaktik (2)
- Karosseriebau (2)
- Kraftfahrzeugbau (2)
Institute
- Fachbereich Medizintechnik und Technomathematik (47)
- IfB - Institut für Bioengineering (22)
- Fachbereich Maschinenbau und Mechatronik (20)
- INB - Institut für Nano- und Biotechnologien (17)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Energietechnik (11)
- Fachbereich Luft- und Raumfahrttechnik (9)
- Fachbereich Elektrotechnik und Informationstechnik (8)
- ECSM European Center for Sustainable Mobility (6)
- Fachbereich Bauingenieurwesen (6)
- Nowum-Energy (6)
- Fachbereich Wirtschaftswissenschaften (4)
- Fachbereich Architektur (3)
- Fachbereich Gestaltung (3)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (3)
- Solar-Institut Jülich (2)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- FH Aachen (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (1)
Herein, fibroin, polylactide (PLA), and carbon are investigated for their suitability as biocompatible and biodegradable materials for amperometric biosensors. For this purpose, screen-printed carbon electrodes on the biodegradable substrates fibroin and PLA are modified with a glucose oxidase membrane and then encapsulated with the biocompatible material Ecoflex. The influence of different curing parameters of the carbon electrodes on the resulting biosensor characteristics is studied. The morphology of the electrodes is investigated by scanning electron microscopy, and the biosensor performance is examined by amperometric measurements of glucose (0.5–10 mM) in phosphate buffer solution, pH 7.4, at an applied potential of 1.2 V versus a Ag/AgCl reference electrode. Instead of Ecoflex, fibroin, PLA, and wound adhesive are tested as alternative encapsulation compounds: a series of swelling tests with different fibroin compositions, PLA, and Ecoflex has been performed before characterizing the most promising candidates by chronoamperometry. Therefore, the carbon electrodes are completely covered with the particular encapsulation material. Chronoamperometric measurements with H2O2 concentrations between 0.5 and 10 mM enable studying the leakage current behavior.