Refine
Year of publication
- 2018 (124) (remove)
Document Type
- Article (124) (remove)
Keywords
- Bahadur efficiency (1)
- Booster Stations (1)
- Buffering Capacity (1)
- Chance Constraint (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- EBSCO Discovery Service (1)
- Engineering Application (1)
- Equivalence test (1)
- Forschungsprozess (1)
- Goodness-of-fit tests for uniformity (1)
- IBM Watson Explorer (1)
- Integrated empirical distribution (survival) function (1)
- Kernel density estimator (1)
- Lab-on-Chip (1)
- Length of confidence intervals (1)
- Literaturanalyse (1)
- MINLP (1)
- Numerical inversion of Laplace transforms (1)
- Pitman efficiency (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (46)
- IfB - Institut für Bioengineering (22)
- INB - Institut für Nano- und Biotechnologien (19)
- Fachbereich Elektrotechnik und Informationstechnik (13)
- Fachbereich Maschinenbau und Mechatronik (13)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Wirtschaftswissenschaften (12)
- Fachbereich Energietechnik (9)
- Fachbereich Bauingenieurwesen (7)
- Fachbereich Luft- und Raumfahrttechnik (7)
- Fachbereich Architektur (3)
- ECSM European Center for Sustainable Mobility (2)
- Institut fuer Angewandte Polymerchemie (2)
- Nowum-Energy (2)
- Fachbereich Gestaltung (1)
- Solar-Institut Jülich (1)
A light-addressable potentiometric sensor (LAPS) is a field-effect-based potentiometric device, which detects concentration changes of an analyte solution on the sensor surface in a spatially resolved way. It uses a light source to generate electron–hole pairs inside the semiconductor, which are separated in the depletion region due to an applied bias voltage across the sensor structure and hence, a surface-potential-dependent photocurrent can be read out. However, depending on the beam angle of the light source, scattering effects can occur, which influence the recorded signal in LAPS-based differential measurements. To solve this problem, a novel illumination unit based on a field programmable gate array (FPGA) consisting of 16 small-sized tunable infrared laser-diode modules (LDMs) is developed. Due to the improved focus of the LDMs with a beam angle of only 2 mrad, undesirable scattering effects are minimized. Escherichia coli (E. coli) K12 bacteria are used as a test microorganism to study the extracellular acidification on the sensor surface. Furthermore, a salt bridge chamber is built up and integrated with the LAPS system enabling multi-chamber differential measurements with a single Ag/AgCl reference electrode.