Refine
Year of publication
- 2006 (160) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (64)
- Fachbereich Luft- und Raumfahrttechnik (21)
- IfB - Institut für Bioengineering (20)
- INB - Institut für Nano- und Biotechnologien (18)
- Fachbereich Elektrotechnik und Informationstechnik (17)
- Fachbereich Maschinenbau und Mechatronik (15)
- Fachbereich Chemie und Biotechnologie (12)
- Fachbereich Energietechnik (12)
- Fachbereich Wirtschaftswissenschaften (7)
- Fachbereich Bauingenieurwesen (3)
Language
- English (160) (remove)
Document Type
- Article (85)
- Conference Proceeding (61)
- Book (9)
- Lecture (2)
- Part of a Book (1)
- Master's Thesis (1)
- Report (1)
Keywords
- Biosensor (23)
- Technische Mechanik (2)
- biosensor (2)
- 3-nitrofluoranthene (1)
- Asteroid Deflection (1)
- BTEX compounds (1)
- Bauingenieurwesen (1)
- Biosensorik (1)
- Bruchmechanik (1)
- CAD (1)
Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds.
In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demonstrated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several additional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings.