Refine
Year of publication
Document Type
- Article (5587)
- Conference Proceeding (1619)
- Book (1078)
- Part of a Book (548)
- Bachelor Thesis (297)
- Patent (172)
- Report (100)
- Doctoral Thesis (78)
- Other (77)
- Administrative publication (76)
- Part of Periodical (63)
- Lecture (30)
- Master's Thesis (20)
- Contribution to a Periodical (19)
- Review (17)
- Diploma Thesis (15)
- Working Paper (13)
- Course Material (9)
- Talk (7)
- Study Thesis (5)
Language
- German (5013)
- English (4801)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Spanish (3)
- nld (2)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (21)
- Studien- und Prüfungsordnung (21)
- Aachen / Fachhochschule Aachen (20)
- Änderungsordnung (20)
- Blitzschutz (18)
- Corporate Design (17)
- Elektromobilität (17)
- CAD (16)
- Finite-Elemente-Methode (16)
- Fotografie (16)
- civil engineering (14)
Institute
- Fachbereich Medizintechnik und Technomathematik (2052)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1138)
- Fachbereich Energietechnik (1104)
- Fachbereich Maschinenbau und Mechatronik (866)
- Fachbereich Chemie und Biotechnologie (847)
- Fachbereich Luft- und Raumfahrttechnik (776)
- Fachbereich Bauingenieurwesen (705)
- IfB - Institut für Bioengineering (686)
- INB - Institut für Nano- und Biotechnologien (613)
- Fachbereich Gestaltung (484)
- Solar-Institut Jülich (339)
- Fachbereich Architektur (174)
- FH Aachen (153)
- ECSM European Center for Sustainable Mobility (112)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (74)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (71)
- Nowum-Energy (70)
- Institut fuer Angewandte Polymerchemie (32)
- Sonstiges (24)
Biomechanical simulation of different prosthetic meshes for repairing uterine/vaginal vault prolapse
(2017)
The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent.
Background
Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far.
Methods
10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed.
Findings
Compared to the control group, the work to fracture could be increased by 33.2%. The fracture force increased by 19.9%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry.
Interpretation
The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results.
Biomasse-Potential
(1985)