Refine
Year of publication
- 2018 (262) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (68)
- Fachbereich Elektrotechnik und Informationstechnik (44)
- IfB - Institut für Bioengineering (41)
- INB - Institut für Nano- und Biotechnologien (25)
- Fachbereich Luft- und Raumfahrttechnik (24)
- Fachbereich Maschinenbau und Mechatronik (24)
- Fachbereich Chemie und Biotechnologie (22)
- Fachbereich Energietechnik (22)
- Fachbereich Wirtschaftswissenschaften (21)
- Fachbereich Bauingenieurwesen (16)
Document Type
- Article (127)
- Conference Proceeding (78)
- Part of a Book (31)
- Book (12)
- Working Paper (3)
- Conference: Meeting Abstract (2)
- Doctoral Thesis (2)
- Patent (2)
- Part of a Periodical (2)
- Conference Poster (1)
Keywords
- Datenschutz (2)
- Digitale Transformation (2)
- Energy efficiency (2)
- Engineering optimization (2)
- Literaturanalyse (2)
- MINLP (2)
- Pump System (2)
- Serious Game (2)
- Water (2)
- Actors (1)
In this paper the results of a techno-economic analysis of improved and optimized molten salt solar tower plants (MSSTP plants) are presented. The potential improvements that were analyzed include different receiver designs, different designs of the HTF-system and plant control, increased molten salt temperatures (up to 640°C) and multi-tower systems. Detailed technological and economic models of the solar field, solar receiver and high temperature fluid system (HTF-system) were developed and used to find potential improvements compared to a reference plant based on Solar Two technology and up-to-date cost estimations. The annual yield model calculates the annual outputs and the LCOE of all variants. An improved external tubular receiver and improved HTF-system achieves a significant decrease of LCOE compared to the reference. This is caused by lower receiver cost as well as improvements of the HTF-system and plant operation strategy, significantly reducing the plant own consumption. A novel star receiver shows potential for further cost decrease. The cavity receiver concepts result in higher LCOE due to their high investment cost, despite achieving higher efficiencies. Increased molten salt temperatures seem possible with an adapted, closed loop HTF-system and achieve comparable results to the original improved system (with 565°C) under the given boundary conditions. In this analysis all multi tower systems show lower economic viability compared to single tower systems, caused by high additional cost for piping connections and higher cost of the receivers.
REFERENCES
Durch die Bauforschung im Rahmen des mehrjährigen Projektes "Die Hochkorridore von Sabbioneta" konnten der Verlauf und viele Anschlüsse der hochliegenden Gänge an bestehende Bauten weitgehend geklärt werden. Im Bereich der Chiesa della SS. Maria Incoronata und des angrenzenden Servitenklosters führten die Bauuntersuchungen zu völlig neuen Erkenntnissen über den ehemaligen Verlauf des Hochkorridors und damit zu einer Neuinterpretation des baulichen Ensembles sowie seiner Bedeutung für die Idealstadt. Aus dieser historischen Umdeutung entstanden Ideen für die Umnutzung des ehemaligen Servitenklosters und seiner angrenzenden Freiflächen, die im Rahmen von studentischen Entwürfen am Lehrstuhl für Baugeschichte und Denkmalpflege in Kooperation mit dem Lehrstuhl für Landschaftsarchitektur der RWTH Aachen weiterentwickelt wurden. Somit stellten sich Befunde einer historisch orientierten Bauforschung mit übergeordneter Fragestellung als neue Impulsgeber für Stadtplanung, Architektur und Denkmalpflege heraus.
Field-effect-based electrolyte-insulator-semiconductor (EIS) sensors were modified with a bilayer of positively charged weak polyelectrolyte (poly(allylamine hydrochloride) (PAH)) and probe single-stranded DNA (ssDNA) and are used for the detection of complementary single-stranded target DNA (cDNA) in different test solutions. The sensing mechanism is based on the detection of the intrinsic molecular charge of target cDNA molecules after the hybridization event between cDNA and immobilized probe ssDNA. The test solutions contain synthetic cDNA oligonucleotides (with a sequence of tuberculosis mycobacteria genome) or PCR-amplified DNA (which origins from a template DNA strand that has been extracted from Mycobacterium avium paratuberculosis-spiked human sputum samples), respectively. Sensor responses up to 41 mV have been measured for the test solutions with DNA, while only small signals of ∼5 mV were detected for solutions without DNA. The lower detection limit of the EIS sensors was ∼0.3 nM, and the sensitivity was ∼7.2 mV/decade. Fluorescence experiments using SybrGreen I fluorescence dye support the electrochemical results.
In this work, a cell-based biosensor to evaluate the sterilization efficacy of hydrogen peroxide vapor sterilization processes is characterized. The transducer of the biosensor is based on interdigitated gold electrodes fabricated on an inert glass substrate. Impedance spectroscopy is applied to evaluate the sensor behavior and the alteration of test microorganisms due to the sterilization process. These alterations are related to changes in relative permittivity and electrical conductivity of the bacterial spores. Sensor measurements are conducted with and without bacterial spores (Bacillus atrophaeus), as well as after an industrial sterilization protocol. Equivalent two-dimensional numerical models based on finite element method of the periodic finger structures of the interdigitated gold electrodes are designed and validated using COMSOL® Multiphysics software by the application of known dielectric properties. The validated models are used to compute the electrical properties at different sensor states (blank, loaded with spores, and after sterilization). As a final result, we will derive and tabulate the frequency-dependent electrical parameters of the spore layer using a novel model that combines experimental data with numerical optimization techniques.
Sterben und Tod aus wissenschaftlicher Sicht - dying and death from a scientific point of view
(2018)
Nach einem intensiven politischen Diskurs wurde im vergangenen Jahr die Datenschutz-Grundverordnung (DSGVO) verabschiedet. Die DSGVO ersetzt zum 25.5.2018 die bislang geltende, aus dem Jahre 1995 stammende Datenschutz-Richtlinie 95/46/EG. Die Novellierung des Datenschutzrechts bringt zahlreiche neue Anforderungen mit sich. Unternehmen sind daher gezwungen, sich auf die Änderungen einzustellen, ihre datenschutzrelevanten Prozesse im Hinblick auf die neuen Anforderungen zu überprüfen und bis zum Mai 2018 an der DSGVO auszurichten. Der Beitrag gibt einen kurzen Überblick über die zentralen Aspekte der Datenschutzreform und die damit einhergehenden Herausforderungen für Unternehmen.