Refine
Year of publication
- 2008 (179) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (51)
- Fachbereich Elektrotechnik und Informationstechnik (29)
- IfB - Institut für Bioengineering (28)
- Fachbereich Wirtschaftswissenschaften (26)
- Fachbereich Energietechnik (17)
- Fachbereich Maschinenbau und Mechatronik (15)
- INB - Institut für Nano- und Biotechnologien (14)
- Fachbereich Bauingenieurwesen (10)
- Fachbereich Chemie und Biotechnologie (10)
- Fachbereich Luft- und Raumfahrttechnik (10)
Has Fulltext
- no (179) (remove)
Document Type
- Article (179) (remove)
Keywords
- Illusion (1)
- Pflanzen <Motiv> (1)
- Photographie (1)
- body limbs (1)
- deserts (1)
- lizards (1)
- magnetic resonance imaging (1)
- swimming (1)
Investigation of TRPV1 loss-of-function phenotypes in transgenic shRNA expressing and knockout mice
(2008)
The sandfish (Scincus scincus) is a lizard having the remarkable ability to move through desert sand for significant distances. It is well adapted to living in loose sand by virtue of a combination of morphological and behavioural specializations. We investigated the bodyform of the sandfish using 3D-laserscanning and explored its locomotion in loose desert sand using fast nuclear magnetic resonance (NMR) imaging. The sandfish exhibits an in-plane meandering motion with a frequency of about 3 Hz and an amplitude of about half its body length accompanied by swimming-like (or trotting) movements of its limbs. No torsion of the body was observed, a movement required for a digging-behaviour. Simple calculations based on the Janssen model for granular material related to our findings on bodyform and locomotor behaviour render a local decompaction of the sand surrounding the moving sandfish very likely. Thus the sand locally behaves as a viscous fluid and not as a solid material. In this fluidised sand the sandfish is able to “swim” using its limbs.
Haftung im Vereinsrecht
(2008)
Entwicklung eines Bemessungsmodells für punktförmige Verbindungen textibewehrter Betonbauteile
(2008)
Wenn eine runde Platine mit LED-Zeile rotiert, entstehen leuchtende Ringe. Steuert man die LEDs mit einem Mikrocontroller an, lassen sich aber auch "stehende" Bilder darstellen. Unser elektronischer Kreisel kann Buchstaben und Ziffern anzeigen. Dabei wird das Erdmagnetfeld auf clevere Weise zur Synchronisation genutzt. Hier reichen die Anwendungen vom Rundenzähler bis zum Kompass!
Due to the interfering effects of acetic acid in many fermentation processes, a gas-diffusion technique was developed for the online determination of acetic acid. The measurements were accomplished with a flow diffusion analysis (FDA) unit from the TRACE Analytics GmbH, Braunschweig, Germany. The diffusion analysis is based on the UV-absorbance of acetic acid at 205 nm. The measurement was achieved by the separation of an acceptor and a carrier stream (acidified fermentation broth) using a gas permeable polytetrafluoroethylene (PTFE) membrane, whereby broth constituents that would otherwise disturb the UV-measurement of acetic acid, are held back efficiently. Merely, the fermentation by-products, e.g. formic acid, is capable of diffusing through the membrane. While formic acid can disturb the measurement, carbon dioxide does not absorb at 205 nm. The method operates with time-dependent sample enrichment. During the analysis, a small volume of the acceptor stream is stopped for a defined time interval in the acceptor chamber. During this period, the gaseous acetic acid diffuses through the membrane and is enriched in the acceptor chamber. Subsequently after the enrichment, the acceptor stream flows through a UV-detector. The intensity of the signal is proportional to the acetic acid concentration. Online measurements in bioreactors via a sterile filtration probe have been accomplished. A linear calibration in the range of 0.5–5.0 g/L acetic acid with a relative standard deviation of <5 % was obtained. A sampling rate of 8 samples per hour was possible. The system was applied for the determination of acetic acid in E. coli fermentation broth. The instrument is easy to clean, very user-friendly and does not require any toxic or expensive reagents.
Calibration of a Network Analyzer Without a Thru Connection for Nonlinear and Multiport Measurements
(2008)
Bluetooth in der Klemme
(2008)
Beyond ClearPET: Next Aims
(2008)
The CRYSTAL CLEAR collaboration, in short CCC, is a consortium of 12 academic institutions, mainly from Europe, joining efforts in the area of developing instrumentation for nuclear medicine and medical imaging. In the framework of the CCC a high performance small animal PET system, called ClearPET, was developed by using new technologies in electronics and crystals in a phoswich arrangement combining two types of lutetium- based scintillator materials: LSO:Ce and LuYAP:Ce. Our next aim will be the development of hybrid image systems. Hybrid MR-PET imaging has many unique advantages for brain research. This has sparked a new research line within CCC for the development of novel MR-PET compatible technologies. MRI is not as sensitive as PET but PET has poorer spatial resolution than MRI. Two major advantages of PET are sensitivity and its ability to acquire metabolic information. To assess these innovations, the development of a 9.4T hybrid animal MR-PET scanner is proposed based on an existing 9.4T MR scanner that will be adapted to enable simultaneous acquisition of MR and PET data using cutting- edge technology for both MR and PET.
Benutzerzentrierte Entwicklung mobiler Unternehmenssoftware, Teil 2 : die Iterative Entwicklung
(2008)
Magnetic Resonance Imaging (MRI) of moving organs requires synchronization with physiological motion or flow, which dictate the viable window for data acquisition. To meet this challenge, this study proposes an acoustic gating device (ACG) that employs acquisition and processing of acoustic signals for synchronization while providing MRI compatibility, immunity to interferences with electro-magnetic and acoustic fields and suitability for MRI at high magnetic field strengths. The applicability and robustness of the acoustic gating approach is examined in a pilot study, where it substitutes conventional ECG-gating for cardiovascular MR. The merits and limitations of the ACG approach are discussed. Implications for MR imaging in the presence of physiological motion are considered including synchronization with other structure- or motion borne sounds.