Refine
Year of publication
- 2015 (284) (remove)
Document Type
- Article (125)
- Conference Proceeding (78)
- Part of a Book (39)
- Book (21)
- Other (7)
- Report (7)
- Doctoral Thesis (5)
- Patent (2)
Has Fulltext
- no (284) (remove)
Keywords
- Attitude dynamics (1)
- Booster Station (1)
- Carsharing (1)
- Charging stations (1)
- Discrete Optimisation (1)
- Discrete Optimization (1)
- E-carsharing (1)
- E-mobility (1)
- Efficiency (1)
- Electrical vehicle (1)
- Energy (1)
- Fully connected car (1)
- Gamma distribution (1)
- Goodness-of-fit test (1)
- Gossamer structures (1)
- Hydraulic structures (1)
- Independence test (1)
- Inductive charging (1)
- Information and communication technology (1)
- Integrated mobility (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (68)
- Fachbereich Wirtschaftswissenschaften (42)
- IfB - Institut für Bioengineering (38)
- INB - Institut für Nano- und Biotechnologien (36)
- Fachbereich Luft- und Raumfahrttechnik (31)
- Fachbereich Chemie und Biotechnologie (30)
- Fachbereich Elektrotechnik und Informationstechnik (30)
- Fachbereich Bauingenieurwesen (26)
- Fachbereich Energietechnik (23)
- Fachbereich Maschinenbau und Mechatronik (22)
- Fachbereich Architektur (8)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (7)
- Solar-Institut Jülich (5)
- Fachbereich Gestaltung (3)
- IBB - Institut für Baustoffe und Baukonstruktionen (3)
- Institut fuer Angewandte Polymerchemie (3)
- Sonstiges (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Nowum-Energy (1)
The present work describes a novel multiple sensor-type system for the real-time analysis of aseptic sterilisation processes employing gaseous hydrogen peroxide (H2O2) as a sterilant. The inactivation kinetics of Bacillus atrophaeus by gaseous H2O2 have been investigated by means of a methodical calibration experiment, taking into account the process variables H2O2 concentration, humidity and gas temperature. It has been found that the microbicidal effectiveness at H2O2 concentrations above 2% v/v is largely determined by the concentration itself, while at lower H2O2 concentrations, the gas temperature and humidity play a leading role. Furthermore, the responses of different types of gas sensors towards the influencing factors of the sterilisation process have been analysed within the same experiment. Based on a correlation established between the inactivation kinetics and the sensor responses, a calorimetric H2O2 sensor and a metal-oxide semiconductor (MOX) sensor have been identified as possible candidates for monitoring the microbicidal effectiveness of aseptic sterilisation processes employing gaseous H2O2. Therefore, two linear models that describe the relationship between sensor response and microbicidal effectiveness have been proposed.