Refine
Year of publication
Document Type
- Conference Proceeding (55) (remove)
Language
- English (55) (remove)
Keywords
- Finite-Elemente-Methode (7)
- Limit analysis (4)
- Einspielen <Werkstoff> (3)
- Shakedown analysis (3)
- shakedown analysis (3)
- Bruchmechanik (2)
- FEM (2)
- Shakedown (2)
- limit analysis (2)
- Analytischer Zulaessigkeitsnachweis (1)
- Anastomose (1)
- Anastomosis (1)
- Biomechanics (1)
- Biomechanik (1)
- Biomedizinische Technik (1)
- Chance constrained programming (1)
- Einspiel-Analyse (1)
- Einspielanalyse (1)
- Elastodynamik (1)
- Evolution of damage (1)
- Exact Ilyushin yield surface (1)
- Extension fracture (1)
- Extension strain criterion (1)
- Festkörper (1)
- Finite element method (1)
- First Order Reliabiblity Method (1)
- First-order reliability method (1)
- Mohr–Coulomb criterion (1)
- Multi-dimensional wave propagation (1)
- Nichtlineare Gleichung (1)
- Nichtlineare Optimierung (1)
- Nichtlineare Welle (1)
- PFM (1)
- Random variable (1)
- Ratcheting (1)
- Reliability of structures (1)
- Sensitivity (1)
- Stochastic programming (1)
- Technische Mechanik (1)
- Traglast (1)
- Traglastanalyse (1)
- Wellen (1)
- design-by-analysis (1)
- finite element analysis (1)
- limit and shakedown analysis (1)
- limit load (1)
- linear kinematic hardening (1)
- lower bound theorem (1)
- material shakedown (1)
- mechanical waves (1)
- nonlinear kinematic hardening (1)
- nonlinear optimization (1)
- nonlinear solids (1)
- nonlinear tensor constitutive equation (1)
- probabilistic fracture mechanics (1)
- ratchetting (1)
- reliability (1)
- second-order reliability method (1)
- shakedown (1)
Institute
A 3D finite element model of the female pelvic floor for the reconstruction of urinary incontinence
(2014)
The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent.