Refine
Year of publication
Document Type
- Article (43)
- Conference Proceeding (4)
Language
- English (47) (remove)
Keywords
- biosensors (3)
- acetoin (2)
- Bacillus atrophaeus (1)
- Bioabsorbable (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect sensor (1)
- Dehydrogenase (1)
- Diaphorase (1)
- Enzymatic biosensor (1)
- Hydrogen peroxide (1)
- Label-free detection (1)
- O2 plasma (1)
- Plant virus (1)
- Polyimide (1)
- Polylactide acid (1)
- Resistive temperature detector (1)
- Silk fibroin (1)
- Simultaneous determination (1)
- Sterilisation process (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tobacco mosaic virus (1)
- Tobacco mosaic virus (TMV) (1)
- Zeta potential (1)
- acetoin reductase (1)
- alcoholic beverages (1)
- amperometric biosensors (1)
- annealing (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive field-effect biosensor (1)
- capacitive field-effect sensor (1)
- capacitive field-effect sensors (1)
- carbon electrodes (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- encapsulation materials (1)
- endospores (1)
- enzyme immobilization (1)
- fibroin (1)
- glucose (1)
- hydroxylation (1)
- immobilization (1)
- organosilanes (1)
- plant virus detection (1)
- silanization (1)
- surface functionalization (1)
- tobacco mosaic virus (TMV) (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (47) (remove)
The light-addressable potentiometric sensor (LAPS) has the unique feature to address different regions of a sensor surface without the need of complex structures. Measurements at different locations on the sensor surface can be performed in a common analyte solution, which distinctly simplifies the fluidic set-up. However, the measurement in a single analyte chamber prevents the application of different drugs or different concentrations of a drug to each measurement spot at the same time as in the case of multi-reservoir-based set-ups. In this work, the authors designed a LAPS-based set-up for cell culture screening that utilises magnetic beads loaded with the endotoxin (lipopolysaccharides, LPS), to generate a spatially distributed gradient of analyte concentration. Different external magnetic fields can be adjusted to move the magnetic beads loaded with a specific drug within the measurement cell. By recording the metabolic activities of a cell layer cultured on top of the LAPS surface, this work shows the possibility to apply different concentrations of a sample along the LAPS measurement spots within a common analyte solution.