Refine
Year of publication
- 2021 (102) (remove)
Document Type
- Article (102) (remove)
Keywords
- Principal component analysis (2)
- capacitive field-effect sensor (2)
- constructive alignment (2)
- examination (2)
- harmonic radar (2)
- long-term retention (2)
- multimodal (2)
- practical learning (2)
- Aircraft sizing (1)
- AlterG (1)
- Authenticity (1)
- Bacillus sp (1)
- Bemessung (1)
- Biosolubilization (1)
- Bloom’s Taxonomy (1)
- Bone quality and biomechanics (1)
- Bootstrap (1)
- CFD (1)
- Capacitive field-effect sensor (1)
- CellDrum (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (38)
- IfB - Institut für Bioengineering (27)
- INB - Institut für Nano- und Biotechnologien (15)
- Fachbereich Wirtschaftswissenschaften (13)
- Fachbereich Chemie und Biotechnologie (11)
- Fachbereich Luft- und Raumfahrttechnik (11)
- Fachbereich Energietechnik (7)
- Fachbereich Bauingenieurwesen (6)
- Fachbereich Elektrotechnik und Informationstechnik (5)
- Fachbereich Maschinenbau und Mechatronik (4)
- Solar-Institut Jülich (4)
- ECSM European Center for Sustainable Mobility (2)
- Fachbereich Architektur (2)
- IBB - Institut für Baustoffe und Baukonstruktionen (2)
- IMP - Institut für Mikrowellen- und Plasmatechnik (2)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (2)
- Nowum-Energy (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
An approach to automatically generate a dynamic energy simulation model in Modelica for a single existing building is presented. It aims at collecting data about the status quo in the preparation of energy retrofits with low effort and costs. The proposed method starts from a polygon model of the outer building envelope obtained from photogrammetrically generated point clouds. The open-source tools TEASER and AixLib are used for data enrichment and model generation. A case study was conducted on a single-family house. The resulting model can accurately reproduce the internal air temperatures during synthetical heating up and cooling down. Modelled and measured whole building heat transfer coefficients (HTC) agree within a 12% range. A sensitivity analysis emphasises the importance of accurate window characterisations and justifies the use of a very simplified interior geometry. Uncertainties arising from the use of archetype U-values are estimated by comparing different typologies, with best- and worst-case estimates showing differences in pre-retrofit heat demand of about ±20% to the average; however, as the assumptions made are permitted by some national standards, the method is already close to practical applicability and opens up a path to quickly estimate possible financial and energy savings after refurbishment.