Article
Refine
Year of publication
- 2021 (80) (remove)
Document Type
- Article (80) (remove)
Language
- English (80) (remove)
Keywords
- Principal component analysis (2)
- capacitive field-effect sensor (2)
- constructive alignment (2)
- examination (2)
- harmonic radar (2)
- long-term retention (2)
- multimodal (2)
- practical learning (2)
- Aircraft sizing (1)
- AlterG (1)
- Authenticity (1)
- Bacillus sp (1)
- Biosolubilization (1)
- Bloom’s Taxonomy (1)
- Bone quality and biomechanics (1)
- Bootstrap (1)
- CFD (1)
- Capacitive field-effect sensor (1)
- CellDrum (1)
- Competence Developing Games (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (38)
- IfB - Institut für Bioengineering (27)
- INB - Institut für Nano- und Biotechnologien (15)
- Fachbereich Chemie und Biotechnologie (11)
- Fachbereich Luft- und Raumfahrttechnik (11)
- Fachbereich Elektrotechnik und Informationstechnik (5)
- Fachbereich Bauingenieurwesen (4)
- Fachbereich Energietechnik (3)
- Solar-Institut Jülich (3)
- ECSM European Center for Sustainable Mobility (2)
- Fachbereich Maschinenbau und Mechatronik (2)
- IMP - Institut für Mikrowellen- und Plasmatechnik (2)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Fachbereich Wirtschaftswissenschaften (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
A new functionalization method to modify capacitive electrolyte–insulator–semiconductor (EIS) structures with nanofilms is presented. Layers of polyallylamine hydrochloride (PAH) and graphene oxide (GO) with the compound polyaniline:poly(2-acrylamido-2-methyl-1-propanesulfonic acid) (PANI:PAAMPSA) are deposited onto a p-Si/SiO2 chip using the layer-by-layer technique (LbL). Two different enzymes (urease and penicillinase) are separately immobilized on top of a five-bilayer stack of the PAH:GO/PANI:PAAMPSA-modified EIS chip, forming a biosensor for detection of urea and penicillin, respectively. Electrochemical characterization is performed by constant capacitance (ConCap) measurements, and the film morphology is characterized by atomic force microscopy (AFM) and scanning electron microscopy (SEM). An increase in the average sensitivity of the modified biosensors (EIS–nanofilm–enzyme) of around 15% is found in relation to sensors, only carrying the enzyme but without the nanofilm (EIS–enzyme). In this sense, the nanofilm acts as a stable bioreceptor onto the EIS chip improving the output signal in terms of sensitivity and stability.