Article
Refine
Year of publication
- 2023 (68) (remove)
Document Type
- Article (68) (remove)
Keywords
- Bacillaceae (2)
- Biotechnological application (2)
- Subtilases (2)
- Subtilisin (2)
- additive manufacturing (2)
- factory planning (2)
- manufacturing flexibility (2)
- ultrasound (2)
- (Poly)saccharides (1)
- 60er Jahre (1)
- Acyl-amino acids (1)
- Aeroelasticity (1)
- Aloe vera (1)
- Aminoacylase (1)
- Anammox (1)
- Antibias (1)
- Architectural design (1)
- Automotive safety approach (1)
- Autonomy (1)
- Bacillus atrophaeus spores (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (23)
- Fachbereich Luft- und Raumfahrttechnik (12)
- ECSM European Center for Sustainable Mobility (11)
- Fachbereich Chemie und Biotechnologie (11)
- INB - Institut für Nano- und Biotechnologien (11)
- Fachbereich Wirtschaftswissenschaften (7)
- IfB - Institut für Bioengineering (7)
- Fachbereich Maschinenbau und Mechatronik (6)
- Fachbereich Energietechnik (5)
- Nowum-Energy (4)
- Fachbereich Bauingenieurwesen (2)
- Fachbereich Elektrotechnik und Informationstechnik (2)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- Fachbereich Architektur (1)
- Institut fuer Angewandte Polymerchemie (1)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (1)
Herein, fibroin, polylactide (PLA), and carbon are investigated for their suitability as biocompatible and biodegradable materials for amperometric biosensors. For this purpose, screen-printed carbon electrodes on the biodegradable substrates fibroin and PLA are modified with a glucose oxidase membrane and then encapsulated with the biocompatible material Ecoflex. The influence of different curing parameters of the carbon electrodes on the resulting biosensor characteristics is studied. The morphology of the electrodes is investigated by scanning electron microscopy, and the biosensor performance is examined by amperometric measurements of glucose (0.5–10 mM) in phosphate buffer solution, pH 7.4, at an applied potential of 1.2 V versus a Ag/AgCl reference electrode. Instead of Ecoflex, fibroin, PLA, and wound adhesive are tested as alternative encapsulation compounds: a series of swelling tests with different fibroin compositions, PLA, and Ecoflex has been performed before characterizing the most promising candidates by chronoamperometry. Therefore, the carbon electrodes are completely covered with the particular encapsulation material. Chronoamperometric measurements with H2O2 concentrations between 0.5 and 10 mM enable studying the leakage current behavior.