Refine
Year of publication
- 2002 (130) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (46)
- Fachbereich Energietechnik (21)
- Fachbereich Elektrotechnik und Informationstechnik (20)
- INB - Institut für Nano- und Biotechnologien (16)
- Fachbereich Chemie und Biotechnologie (13)
- IfB - Institut für Bioengineering (10)
- Fachbereich Luft- und Raumfahrttechnik (8)
- Solar-Institut Jülich (8)
- Fachbereich Wirtschaftswissenschaften (7)
- Fachbereich Gestaltung (2)
Language
- English (130) (remove)
Document Type
- Article (92)
- Conference Proceeding (25)
- Book (12)
- Patent (1)
Keywords
- Blitzschutz (2)
- Biomedizinische Technik (1)
- Bruchmechanik (1)
- CAD (1)
- CAD ; (1)
- Direkter Blitzschlag (1)
- Einspielen <Werkstoff> (1)
- Elektromagnetischer Schutzschild (1)
- Erneuerbare Energien (1)
- Gasturbine (1)
- Hybridsystem (1)
- Induzierte Spannungen (1)
- Lightning (1)
- Lightning protection (1)
- Lightning protection system (1)
- Magnetische Felder (1)
- Micro turbine (1)
- Mikrogasturbine (1)
- Photovoltaikanlage (1)
- Ratcheting (1)
- Risikoabwägung (1)
- Shakedown (1)
- Stahlbetonkonstruktion (1)
- Windenergieanlage (1)
- civil engineering (1)
- electromagnetic shielding (1)
- hybrid system (1)
- induced voltage (1)
- linear kinematic hardening (1)
- magnetic field (1)
- material shakedown (1)
- nonlinear kinematic hardening (1)
- photovoltaic system (1)
- protection measures (1)
- ratchetting (1)
- reinforced concrete (1)
- renewable energy (1)
- risk assessment (1)
- shakedown (1)
- wind turbine (1)
A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture.