Refine
Year of publication
- 2015 (61) (remove)
Document Type
- Article (41)
- Conference Proceeding (14)
- Part of a Book (4)
- Doctoral Thesis (2)
Language
- English (61) (remove)
Keywords
- Booster Station (1)
- Discrete Optimization (1)
- Gamma distribution (1)
- Goodness-of-fit test (1)
- Independence test (1)
- Limit analysis (1)
- Multimode failure (1)
- Non-linear optimization (1)
- Parametric bootstrap (1)
- Pump System (1)
- Reliability analysis (1)
- Shakedown analysis (1)
- Technical Operations Research (TOR) (1)
- Vapnik–Čhervonenkis class (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (61) (remove)
The chemical imaging sensor is a field-effect sensor which is able to visualize both the distribution of ions (in LAPS mode) and the distribution of impedance (in SPIM mode) inthe sample. In this study, a novel wound-healing assay is proposed, in which the chemical imaging sensor operated in SPIM mode is applied to monitor the defect of a cell layer brought into proximity of the sensing surface.A reduced impedance inside the defect, which was artificially formed ina cell layer, was successfully visualized in a photocurrent image.