Refine
Year of publication
- 2016 (154) (remove)
Document Type
- Article (78)
- Conference Proceeding (65)
- Part of a Book (7)
- Book (2)
- Doctoral Thesis (1)
- Report (1)
Language
- English (154) (remove)
Keywords
- Technical Operations Research (2)
- Additive Manufacturing (1)
- Annulus Fibrosus (1)
- Assessment (1)
- Asymptotic efficiency (1)
- Bacillus atrophaeus (1)
- Balance (1)
- Balanced hypergraph (1)
- Building Systems (1)
- Business Simulations (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Censored data (1)
- Co-managed care (1)
- Collaborative robot (1)
- Computational biomechanics (1)
- Controller Parameter (1)
- DNA biosensor (1)
- Disc Degeneration (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (43)
- IfB - Institut für Bioengineering (29)
- Fachbereich Chemie und Biotechnologie (26)
- Fachbereich Elektrotechnik und Informationstechnik (26)
- Fachbereich Luft- und Raumfahrttechnik (21)
- Fachbereich Bauingenieurwesen (13)
- INB - Institut für Nano- und Biotechnologien (13)
- Fachbereich Maschinenbau und Mechatronik (12)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (11)
- Fachbereich Energietechnik (10)
- Institut fuer Angewandte Polymerchemie (5)
- ECSM European Center for Sustainable Mobility (4)
- Fachbereich Wirtschaftswissenschaften (3)
- Nowum-Energy (3)
- Fachbereich Architektur (2)
- Fachbereich Gestaltung (1)
- Solar-Institut Jülich (1)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (1)
Purpose
To assess the feasibility of prostate ¹H MR spectroscopic imaging (MRSI) using low-power spectral-spatial (SPSP) pulses at 7T, exploiting accurate spectral selection and spatial selectivity simultaneously.
Methods
A double spin-echo sequence was equipped with SPSP refocusing pulses with a spectral selectivity of 1 ppm. Three-dimensional prostate ¹H-MRSI at 7T was performed with the SPSP-MRSI sequence using an 8-channel transmit array coil and an endorectal receive coil in three patients with prostate cancer and in one healthy subject. No additional water or lipid suppression pulses were used.
Results
Prostate ¹H-MRSI could be obtained well within specific absorption rate (SAR) limits in a clinically feasible time (10 min). Next to the common citrate signals, the prostate spectra exhibited high spermine signals concealing creatine and sometimes also choline. Residual lipid signals were observed at the edges of the prostate because of limitations in spectral and spatial selectivity.
Conclusion
It is possible to perform prostate ¹H-MRSI at 7T with a SPSP-MRSI sequence while using separate transmit and receive coils. This low-SAR MRSI concept provides the opportunity to increase spatial resolution of MRSI within reasonable scan times.