Refine
Year of publication
- 2018 (68) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (68) (remove)
Document Type
- Article (47)
- Part of a Book (9)
- Conference Proceeding (7)
- Book (4)
- Doctoral Thesis (1)
Keywords
- Bladder (1)
- Chemical imaging (1)
- Coat protein (1)
- Conductive boundary condition (1)
- Coverage probability (1)
- Cramér-von-Mises statistic (1)
- Dry surfaces (1)
- Enzyme nanocarrier (1)
- Equivalence test (1)
- Field-effect device (1)
- Glucose biosensor (1)
- Glucose oxidase (1)
- Goodness-of-fit tests for uniformity (1)
- Growth modelling (1)
- Integrated empirical distribution (survival) function (1)
- Inverse scattering (1)
- Lab-on-Chip (1)
- Light-addressable potentiometric sensor (1)
- Mechanical simulation (1)
- Microbial adhesion (1)
- Muscle fibers (1)
- Numerical inversion of Laplace transforms (1)
- Passive stretching (1)
- Pelvic floor dysfunction (1)
- Pelvic muscle (1)
- Potentiometry (1)
- Reconstruction (1)
- Rehabilitation Technology and Prosthetics (1)
- Sampling methods (1)
- Surface microorganisms (1)
- Surgical Navigation and Robotics (1)
- Swabbing (1)
- Tobacco mosaic virus (TMV) (1)
- Transmission eigenvalues (1)
- Ureter (1)
- achilles tendon (1)
- energy absorption (1)
- energy dissipation (1)
- frequency mixing (1)
- functional data (1)
- huge dimensional data (1)
- magnetic beads (1)
- magnetic sensing (1)
- mechanical buffer (1)
- separable Hilbert space (1)
- stiffness (1)
- superparamagnetic nanoparticles (1)
Is part of the Bibliography
- no (68)
Multi-analyte biosensors may offer the opportunity to perform cost-effective and rapid analysis with reduced sample volume, as compared to electrochemical biosensing of each analyte individually. This work describes the development of an enzyme-based biosensor system for multi-parametric determination of four different organic acids. The biosensor array comprises five working electrodes for simultaneous sensing of ethanol, formate, d-lactate, and l-lactate, and an integrated counter electrode. Storage stability of the biosensor was evaluated under different conditions (stored at +4 °C in buffer solution and dry at −21 °C, +4 °C, and room temperature) over a period of 140 days. After repeated and regular application, the individual sensing electrodes exhibited the best stability when stored at −21 °C. Furthermore, measurements in silage samples (maize and sugarcane silage) were conducted with the portable biosensor system. Comparison with a conventional photometric technique demonstrated successful employment for rapid monitoring of complex media.