Refine
Year of publication
- 2022 (42) (remove)
Document Type
- Article (31)
- Conference Proceeding (7)
- Part of a Book (2)
- Book (1)
- Other (1)
Language
- English (42) (remove)
Keywords
- Biocomposites (2)
- Natural fibres (2)
- Polymer-matrix composites (2)
- Stress concentrations (2)
- damage (2)
- Alzheimer's disease (1)
- Biomechanical simulation (1)
- Bootstrapping (1)
- Categorial variable (1)
- Cementoblast (1)
- Chance constrained programming (1)
- Clustering (1)
- Collective risk model (1)
- Compression (1)
- Concomitant (1)
- ES-FEM (1)
- Empirical process (1)
- Evolution of damage (1)
- Extension fracture (1)
- Extension strain criterion (1)
- FGF23 (1)
- FS-FEM (1)
- Finite element analysis (1)
- Finite element analysis (FEA) (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Haemodialysis (1)
- Handbike (1)
- Heterostructure (1)
- Image Reconstruction (1)
- Independence test (1)
- Information Extraction (1)
- Klotho (1)
- Limit analysis (1)
- Machine learning (1)
- Mechanotransduction (1)
- Metascintillator (1)
- Microcirculation (1)
- Mild cognitive impairment (1)
- Mohr–Coulomb criterion (1)
- Multiple TOF kernels (1)
- Myocardial infarction and cardiac death (1)
- Natural Language Processing (1)
- Niacin (1)
- PTH (1)
- Paralympic sport (1)
- Phosphate (1)
- Profile Extraction (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- Reliability of structures (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Riboflavin (1)
- Rotator cuff (1)
- S-FEM (1)
- Shakedown analysis (1)
- Stochastic programming (1)
- TOF PET (1)
- Tension (1)
- Text Mining (1)
- Thiamine (1)
- Tobacco mosaic virus (1)
- Vasomotions (1)
- Vitamin A (1)
- Vitamin B (1)
- Vitamin D (1)
- acetoin (1)
- adipose-derived stromal cells (ASCs) (1)
- anaesthetic complications (1)
- anisotropy (1)
- aortic perfusion (1)
- atomic layer deposition (1)
- biaxial tensile experiment (1)
- biocompatible materials (1)
- biodegradable electronic devices (1)
- biopotential electrodes (1)
- biosensors (1)
- bootstrap (1)
- capacitive field-effect biosensor (1)
- capacitive field-effect sensors (1)
- carbon electrodes (1)
- cell aerosolization (1)
- cell atomization (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- cognitive impairment (1)
- computational fluid dynamics analysis (1)
- constitutive modeling (1)
- correlation (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- distorted element (1)
- double-lumen tube intubation (1)
- endoluminal (1)
- enzyme immobilization (1)
- extracorporeal membrane oxygenation (1)
- force generation (1)
- forehead EEG (1)
- glucose (1)
- high-intensity exercise (1)
- hyperelastic (1)
- impedance spectroscopy (1)
- in-ear EEG (1)
- limit analysis (1)
- muscle fascicle behavior (1)
- non-simplex S-FEM elements (1)
- pH sensors (1)
- performance testing (1)
- reliability of structures (1)
- retinal vessels (1)
- sEMG (1)
- shakedown analysis (1)
- simulation (1)
- smooth muscle contraction (1)
- stochastic programming (1)
- strain energy function (1)
- survival (1)
- tendon rupture (1)
- tri-lineage differentiation (1)
- twin-fluid atomizer (1)
- ultrasound imaging (1)
- ultrathin gate insulators (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- walking gait (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (42) (remove)
Introduction
In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration.
Materials and methods
Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer’s classification was used to analyse the fractures.
Results
In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities.
Conclusion
A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education.