Refine
Year of publication
- 2016 (41) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (41) (remove)
Has Fulltext
- no (41) (remove)
Language
- English (41) (remove)
Document Type
- Article (29)
- Conference Proceeding (11)
- Part of a Book (1)
Keywords
- Annulus Fibrosus (1)
- Asymptotic efficiency (1)
- Bacillus atrophaeus (1)
- Balance (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Censored data (1)
- Co-managed care (1)
- Computational biomechanics (1)
- DNA biosensor (1)
- Disc Degeneration (1)
- Drug simulation (1)
- Elderly (1)
- Electromechanical modeling (1)
- External knee adduction moments (1)
- Fall prevention (1)
- Field effect (1)
- Frequency adaption (1)
- Ground-level falls (1)
- Heart tissue culture (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ion channels (1)
- LAPS (1)
- Label-free detection (1)
- Layer-by-layer adsorption (1)
- Manipulated variables (1)
- Mobility (1)
- Mobility tests (1)
- Musculoskeletal model (1)
- Nucleus Pulposus (1)
- Pharmacology (1)
- Poly(allylamine hydrochloride) (1)
- Product-integration (1)
- Semi-parametric random censorship model (1)
- Survival analysis (1)
- Tinetti test (1)
- Volterra integral equation (1)
- biosensors (1)
- chemical sensor (1)
- endospores (1)
- hiPS cardiomyocytes (1)
- immobilization (1)
- light-addressable potentiometric sensor (1)
- organosilanes (1)
- plug-based microfluidic device (1)
- silanization (1)
The light-addressable potentiometric sensor (LAPS) has the unique feature to address different regions of a sensor surface without the need of complex structures. Measurements at different locations on the sensor surface can be performed in a common analyte solution, which distinctly simplifies the fluidic set-up. However, the measurement in a single analyte chamber prevents the application of different drugs or different concentrations of a drug to each measurement spot at the same time as in the case of multi-reservoir-based set-ups. In this work, the authors designed a LAPS-based set-up for cell culture screening that utilises magnetic beads loaded with the endotoxin (lipopolysaccharides, LPS), to generate a spatially distributed gradient of analyte concentration. Different external magnetic fields can be adjusted to move the magnetic beads loaded with a specific drug within the measurement cell. By recording the metabolic activities of a cell layer cultured on top of the LAPS surface, this work shows the possibility to apply different concentrations of a sample along the LAPS measurement spots within a common analyte solution.