Refine
Year of publication
Document Type
- Article (43)
- Conference Proceeding (4)
Language
- English (47) (remove)
Keywords
- biosensors (3)
- acetoin (2)
- Bacillus atrophaeus (1)
- Bioabsorbable (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect sensor (1)
- Dehydrogenase (1)
- Diaphorase (1)
- Enzymatic biosensor (1)
- Hydrogen peroxide (1)
- Label-free detection (1)
- O2 plasma (1)
- Plant virus (1)
- Polyimide (1)
- Polylactide acid (1)
- Resistive temperature detector (1)
- Silk fibroin (1)
- Simultaneous determination (1)
- Sterilisation process (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tobacco mosaic virus (1)
- Tobacco mosaic virus (TMV) (1)
- Zeta potential (1)
- acetoin reductase (1)
- alcoholic beverages (1)
- amperometric biosensors (1)
- annealing (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive field-effect biosensor (1)
- capacitive field-effect sensor (1)
- capacitive field-effect sensors (1)
- carbon electrodes (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- encapsulation materials (1)
- endospores (1)
- enzyme immobilization (1)
- fibroin (1)
- glucose (1)
- hydroxylation (1)
- immobilization (1)
- organosilanes (1)
- plant virus detection (1)
- silanization (1)
- surface functionalization (1)
- tobacco mosaic virus (TMV) (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (47) (remove)
A concept for a new generation of an integrated multi-functional biosensor/actuator system is developed, which is based on biomolecular logic principles. Such a system is expected to be able to detect multiple biochemical input signals simultaneously and in real-time and convert them into electrical output signals with logical operations such as OR, AND, etc. The system can be designed as a closed-loop drug release device triggered by an enzyme logic gate, while the release of the drug induced by the actuator at the required dosage and timing will be controlled by an additional drug sensor. Thus, the system could help to make an accurate and specific diagnosis. The presented concept is exemplarily demonstrated by using an enzyme logic gate based on a glucose/glucose oxidase system, a temperature-responsive hydrogel mimicking the actuator function and an insulin (drug) sensor. In this work, the results of functional testing of individual amperometric glucose and insulin sensors as well as an impedimetric sensor for the detection of the hydrogel swelling/shrinking are presented.