Refine
Year of publication
Document Type
- Article (43)
- Conference Proceeding (4)
Language
- English (47) (remove)
Keywords
- biosensors (3)
- acetoin (2)
- Bacillus atrophaeus (1)
- Bioabsorbable (1)
- Calorimetric gas sensor (1)
- Capacitive field-effect sensor (1)
- Dehydrogenase (1)
- Diaphorase (1)
- Enzymatic biosensor (1)
- Hydrogen peroxide (1)
- Label-free detection (1)
- O2 plasma (1)
- Plant virus (1)
- Polyimide (1)
- Polylactide acid (1)
- Resistive temperature detector (1)
- Silk fibroin (1)
- Simultaneous determination (1)
- Sterilisation process (1)
- TMV adsorption (1)
- Ta₂O₅ gate (1)
- Tobacco mosaic virus (1)
- Tobacco mosaic virus (TMV) (1)
- Zeta potential (1)
- acetoin reductase (1)
- alcoholic beverages (1)
- amperometric biosensors (1)
- annealing (1)
- biocompatible (1)
- biocompatible materials (1)
- biodegradabl (1)
- biodegradable electronic devices (1)
- calorimetric gas sensor;hydrogen peroxide;wireless sensor system (1)
- capacitive field-effect biosensor (1)
- capacitive field-effect sensor (1)
- capacitive field-effect sensors (1)
- carbon electrodes (1)
- electrolyte-insulator semiconductor sensor (EIS) (1)
- encapsulation materials (1)
- endospores (1)
- enzyme immobilization (1)
- fibroin (1)
- glucose (1)
- hydroxylation (1)
- immobilization (1)
- organosilanes (1)
- plant virus detection (1)
- silanization (1)
- surface functionalization (1)
- tobacco mosaic virus (TMV) (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (47) (remove)
A chip-based amperometric biosensor referring on using the bioelectrocatalytical amplification principle for the detection of low adrenaline concentrations is presented. The adrenaline biosensor has been prepared by modification of a platinum thin-film electrode with an enzyme membrane containing the pyrroloquinoline quinone-dependent glucose dehydrogenase and glutaraldehyde. Measuring conditions such as temperature, pH value, and glucose concentration have been optimized to achieve a high sensitivity and a low detection limit of about 1 nM adrenaline measured in phosphate buffer at neutral pH value. The response of the biosensor to different catecholamines has also been proven. Long-term stability of the adrenaline biosensor has been studied over 10 days. In addition, the biosensor has been successfully applied for adrenaline detection in human blood plasma for future biomedical applications. Furthermore, preliminary experiments have been carried to detect the adrenaline-concentration difference measured in peripheral blood and adrenal venous blood, representing the adrenal vein sampling procedure of a physician.