Conference Proceeding
Refine
Year of publication
Document Type
- Conference Proceeding (129) (remove)
Keywords
- Out-of-plane load (3)
- earthquakes (3)
- Adjacent buildings (2)
- Historical centres (2)
- INODIS (2)
- Seismic loading (2)
- Shake table test (2)
- Stone masonry (2)
- industrial facilities (2)
- installations (2)
- piping (2)
- seismic design (2)
- seismic loading (2)
- Ausfachungsmauerwerk (1)
- Blind prediction competition (1)
- Capacity Curve (1)
- EN 1998-4 (1)
- ESHM20, industrial facilities (1)
- Earthquake (1)
- Earthquake Engineering (1)
Institute
Seismic excited liquid filled tanks are subjected to extreme loading due to hydrodynamic pressures, which can lead to nonlinear stability failure of the thinwalled cylindrical tanks, as it is known from past earthquakes. A significant reduction of the seismically induced loads can be obtained by the application of base isolation systems, which have to be designed carefully with respect to the modified hydrodynamic behaviour of the tank in interaction with the liquid. For this reason a highly sophisticated fluid-structure interaction model has to be applied for a realistic simulation of the overall dynamic system. In the following, such a model is presented and compared with the results of simplified mathematical models for rigidly supported tanks. Finally, it is examined to what extent a simple mechanical model can represent the behaviour of a base isolated tank in case of seismic excitation