Refine
Year of publication
- 2016 (268) (remove)
Document Type
- Article (116)
- Conference Proceeding (80)
- Part of a Book (27)
- Book (23)
- Other (10)
- Report (5)
- Doctoral Thesis (3)
- Part of Periodical (2)
- Patent (1)
- Talk (1)
Keywords
- Technical Operations Research (2)
- Additive Manufacturing (1)
- Annulus Fibrosus (1)
- Assessment (1)
- Asymptotic efficiency (1)
- Bacillus atrophaeus (1)
- Balance (1)
- Balanced hypergraph (1)
- Brandfall (1)
- Building Systems (1)
- Business Simulations (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Censored data (1)
- Co-managed care (1)
- Collaborative robot (1)
- Computational biomechanics (1)
- Controller Parameter (1)
- DNA biosensor (1)
- Designpraxis (1)
- Disc Degeneration (1)
- Diversity (1)
- Drinking Water Supply (1)
- Drug simulation (1)
- Duality (1)
- EN 1993-1-2 (1)
- Effizienz (1)
- Einbetten in das Internet der Dinge (1)
- Elderly (1)
- Electromechanical modeling (1)
- Engineering Education (1)
- Eutectic Silver Copper alloy (1)
- External knee adduction moments (1)
- Fall prevention (1)
- Field effect (1)
- Forschung, pränormativ (1)
- Frequency adaption (1)
- Gamification (1)
- Gender (1)
- Ground-level falls (1)
- Hall’s Theorem (1)
- Heart tissue culture (1)
- Higher Education (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Human-Robot interaction (1)
- Hypergraph (1)
- Hypothesentests (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ion channels (1)
- Koenig’s Theorem (1)
- LAPS (1)
- Label-free detection (1)
- Layer-by-layer adsorption (1)
- Level Control System (1)
- Manipulated variables (1)
- Matching (1)
- Minimal-Ansatz für Embedded-Systeme (1)
- Mixed Integer Programming (1)
- Mixed-Integer Nonlinear Optimisation (1)
- Mobility (1)
- Mobility tests (1)
- Musculoskeletal model (1)
- Nucleus Pulposus (1)
- Optimal Closed Loop (1)
- Optimal Topology (1)
- Optimization (1)
- Parametric Design (1)
- Parametric Modelling (1)
- Path planning (1)
- Pharmacology (1)
- Poly(allylamine hydrochloride) (1)
- Porositat (1)
- Product-integration (1)
- Reference Process Model (1)
- Referenzmodellierung (1)
- Response Surface Method (1)
- SLM (1)
- Safety concept (1)
- Semi-parametric random censorship model (1)
- Serious Games (1)
- Solver Per- formance (1)
- Structuralist Architecture (1)
- Subject-oriented Business Process Management (1)
- Survival analysis (1)
- System Design (1)
- System Design Problem (1)
- TM Forum (1)
- TTIP (1)
- Technical Operation Research (1)
- Telecommunications Industry. (1)
- Tinetti test (1)
- Tragwerksbemessung (1)
- Unternehmensarchitektur (1)
- Unternehmenstransformation (1)
- Vergleich von Experimenten (1)
- Vertex cover (1)
- Volterra integral equation (1)
- Workspace monitoring (1)
- biosensors (1)
- building industry (1)
- chemical sensor (1)
- diversity (1)
- eTOM (1)
- efficiency (1)
- electronic communications markets (1)
- endospores (1)
- energy disspation (1)
- engineering education (1)
- enhanced Telecom Operations Map (eTOM) (1)
- friction (1)
- hiPS cardiomyocytes (1)
- immobilization (1)
- impulsive effects (1)
- industrial research (1)
- ingot (1)
- innovation (1)
- iron and steel industry (1)
- liberalisation (1)
- light-addressable potentiometric sensor (1)
- liquid-storage tank (1)
- liquid-structure interaction (1)
- materials technology (1)
- metal structure (1)
- organosilanes (1)
- plug-based microfluidic device (1)
- regulation (1)
- research project (1)
- research report (1)
- resistance of materials (1)
- seismic response (1)
- silanization (1)
- social responsible engineering (1)
- steel (1)
- structural design (1)
- structure-soil-structure interaction (1)
- testing hypotheses (1)
- wave run-up (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (54)
- Fachbereich Chemie und Biotechnologie (36)
- Fachbereich Bauingenieurwesen (35)
- Fachbereich Elektrotechnik und Informationstechnik (35)
- IfB - Institut für Bioengineering (35)
- Fachbereich Wirtschaftswissenschaften (31)
- Fachbereich Luft- und Raumfahrttechnik (27)
- Fachbereich Maschinenbau und Mechatronik (25)
- Fachbereich Energietechnik (17)
- INB - Institut für Nano- und Biotechnologien (15)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (11)
- Institut fuer Angewandte Polymerchemie (5)
- Nowum-Energy (5)
- Solar-Institut Jülich (5)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (5)
- ECSM European Center for Sustainable Mobility (4)
- Fachbereich Architektur (4)
- FH Aachen (2)
- IBB - Institut für Baustoffe und Baukonstruktionen (2)
- Fachbereich Gestaltung (1)
Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study
(2016)
Background
Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH.
Methods
In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2–14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling.
Results
Image quality was satisfactory in the majority of cases (93.3%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion.
Conclusion
RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort.