Conference Proceeding
Refine
Year of publication
- 2022 (43) (remove)
Document Type
- Conference Proceeding (43) (remove)
Has Fulltext
- no (43) (remove)
Keywords
- Concentrated solar power (3)
- Energy storage (3)
- Hybrid energy system (3)
- Digital Twin (2)
- Electricity generation (2)
- IO-Link (2)
- Power plants (2)
- Solar thermal technologies (2)
- seismic design (2)
- 10BASE-T1L (1)
- Additive Manufacturing (1)
- Additive manufacturing (1)
- Angle Sensor (1)
- Arduino (1)
- Artificial Intelligence (1)
- Asset Administration Shell (1)
- Associated liquids (1)
- Binder Jetting (1)
- Camera system (1)
- Case Study (1)
Institute
- Fachbereich Energietechnik (16)
- ECSM European Center for Sustainable Mobility (13)
- Solar-Institut Jülich (10)
- Kommission für Forschung und Entwicklung (9)
- Fachbereich Maschinenbau und Mechatronik (7)
- Fachbereich Medizintechnik und Technomathematik (7)
- Fachbereich Elektrotechnik und Informationstechnik (6)
- Fachbereich Luft- und Raumfahrttechnik (4)
- Fachbereich Wirtschaftswissenschaften (4)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (4)
- IfB - Institut für Bioengineering (2)
- Fachbereich Bauingenieurwesen (1)
- INB - Institut für Nano- und Biotechnologien (1)
Concentrated Solar Power (CSP) systems are able to store energy cost-effectively in their integrated thermal energy storage (TES). By intelligently combining Photovoltaics (PV) systems with CSP, a further cost reduction of solar power plants is expected, as well as an increase in dispatchability and flexibility of power generation. PV-powered Resistance Heaters (RH) can be deployed to raise the temperature of the molten salt hot storage from 385 °C up to 565 °C in a Parabolic Trough Collector (PTC) plant. To avoid freezing and decomposition of molten salt, the temperature distribution in the electrical resistance heater is investigated in the present study. For this purpose, a RH has been modeled and CFD simulations have been performed. The simulation results show that the hottest regions occur on the electric rod surface behind the last baffle. A technical optimization was performed by adjusting three parameters: Shell-baffle clearance, electric rod-baffle clearance and number of baffles. After the technical optimization was carried out, the temperature difference between the maximum temperature and the average outlet temperature of the salt is within the acceptable limits, thus critical salt decomposition has been avoided. Additionally, the CFD simulations results were analyzed and compared with results obtained with a one-dimensional model in Modelica.