Konferenzveröffentlichung
Filtern
Erscheinungsjahr
Institut
- Fachbereich Elektrotechnik und Informationstechnik (241)
- Fachbereich Medizintechnik und Technomathematik (217)
- Fachbereich Luft- und Raumfahrttechnik (188)
- Fachbereich Energietechnik (181)
- IfB - Institut für Bioengineering (151)
- Solar-Institut Jülich (110)
- Fachbereich Maschinenbau und Mechatronik (107)
- Fachbereich Bauingenieurwesen (75)
- Fachbereich Wirtschaftswissenschaften (55)
- ECSM European Center for Sustainable Mobility (53)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (46)
- INB - Institut für Nano- und Biotechnologien (39)
- Fachbereich Chemie und Biotechnologie (24)
- Kommission für Forschung und Entwicklung (17)
- Nowum-Energy (11)
- Fachbereich Architektur (9)
- Fachbereich Gestaltung (4)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (2)
- Institut fuer Angewandte Polymerchemie (2)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- Digitalisierung in Studium & Lehre (1)
- Freshman Institute (1)
- IaAM - Institut für angewandte Automation und Mechatronik (1)
- Kommission für Planung und Finanzen (1)
- Senat (1)
Sprache
- Englisch (1191) (entfernen)
Dokumenttyp
- Konferenzveröffentlichung (1191) (entfernen)
Schlagworte
- Biosensor (25)
- CAD (7)
- Finite-Elemente-Methode (7)
- civil engineering (7)
- Bauingenieurwesen (6)
- Blitzschutz (6)
- Enterprise Architecture (5)
- Clusterion (4)
- Energy storage (4)
- Gamification (4)
Reinforced concrete frames with masonry infill walls are popular form of construction all over the world as well in seismic regions. While severe earthquakes can cause high level of damage of both reinforced concrete and masonry infills, earthquakes of lower to medium intensity some-times can cause significant level of damage of masonry infill walls. Especially important is the level of damage of face loaded infill masonry walls (out-of-plane direction) as out-of-plane load cannot only bring high level of damage to the wall, it can also be life-threating for the people near the wall. The response in out-of-plane direction directly depends on the prior in-plane damage, as previous investigation shown that it decreases resistance capacity of the in-fills. Behaviour of infill masonry walls with and without prior in-plane load is investigated in the experimental campaign and the results are presented in this paper. These results are later compared with analytical approaches for the out-of-plane resistance from the literature. Conclusions based on the experimental campaign on the influence of prior in-plane damage on the out-of-plane response of infill walls are compared with the conclusions from other authors who investigated the same problematic.
Due to the increasing complexity of software projects, software development is becoming more and more dependent on teams. The quality of this teamwork can vary depending on the team composition, as teams are always a combination of different skills and personality types. This paper aims to answer the question of how to describe a software development team and what influence the personality of the team members has on the team dynamics. For this purpose, a systematic literature review (n=48) and a literature search with the AI research assistant Elicit (n=20) were conducted. Result: A person’s personality significantly shapes his or her thinking and actions, which in turn influences his or her behavior in software development teams. It has been shown that team performance and satisfaction can be strongly influenced by personality. The quality of communication and the likelihood of conflict can also be attributed to personality.
Many of today’s factors make software development more and more complex, such as time pressure, new technologies, IT security risks, et cetera. Thus, a good preparation of current as well as future software developers in terms of a good software engineering education becomes progressively important. As current research shows, Competence Developing Games (CDGs) and Serious Games can offer a potential solution.
This paper identifies the necessary requirements for CDGs to be conducive in principle, but especially in software engineering (SE) education. For this purpose, the current state of research was summarized in the context of a literature review. Afterwards, some of the identified requirements as well as some additional requirements were evaluated by a survey in terms of subjective relevance.
Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables.
For the application of the concept of Lightning Protection Zones (LPZ), the knowledge of the magnetic fields and induced voltages inside a structure is necessary. Laboratory experiments have been conducted at a downscaled model of a building (scale factor 1:6) to determine these electromagnetic quantities in case of a direct strike to the structure. The model (3 m x 2 m x 2 m) represented a small industrial building using the reinforcement of the concrete as electromagnetic shield. The magnetic fields and magnetic field derivatives were measured at several location inside the scaled model. Further, the voltages induced on three typical cable routes inside the model was determined. The influence of the lightning current waveshape, point-of-strike, bonding of the cable routes, and bridging of an expansion joint in the middle of the building on these quantities was studied.
In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.