Article
Refine
Year of publication
- 2019 (121) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (52)
- IfB - Institut für Bioengineering (27)
- INB - Institut für Nano- und Biotechnologien (20)
- Fachbereich Luft- und Raumfahrttechnik (12)
- Fachbereich Energietechnik (11)
- Fachbereich Wirtschaftswissenschaften (11)
- Fachbereich Elektrotechnik und Informationstechnik (9)
- Fachbereich Maschinenbau und Mechatronik (8)
- Fachbereich Bauingenieurwesen (7)
- Fachbereich Chemie und Biotechnologie (7)
Document Type
- Article (121) (remove)
Keywords
- Achilles tendon (1)
- Arbeit 4.0 (1)
- Architectural gear ratio (1)
- Assistive technology (1)
- Automatic control (1)
- Chatbots (1)
- Datenschutz (1)
- Datenschutzgrundverordnung (1)
- Digitalisierung (1)
- Emilia-Romagna earthquake (1)
Is part of the Bibliography
- no (121)
Suppose we have k samples X₁,₁,…,X₁,ₙ₁,…,Xₖ,₁,…,Xₖ,ₙₖ with different sample sizes ₙ₁,…,ₙₖ and unknown underlying distribution functions F₁,…,Fₖ as observations plus k families of distribution functions {G₁(⋅,ϑ);ϑ∈Θ},…,{Gₖ(⋅,ϑ);ϑ∈Θ}, each indexed by elements ϑ from the same parameter set Θ, we consider the new goodness-of-fit problem whether or not (F₁,…,Fₖ) belongs to the parametric family {(G₁(⋅,ϑ),…,Gₖ(⋅,ϑ));ϑ∈Θ}. New test statistics are presented and a parametric bootstrap procedure for the approximation of the unknown null distributions is discussed. Under regularity assumptions, it is proved that the approximation works asymptotically, and the limiting distributions of the test statistics in the null hypothesis case are determined. Simulation studies investigate the quality of the new approach for small and moderate sample sizes. Applications to real-data sets illustrate how the idea can be used for verifying model assumptions.
Kurz vor der parlamentarischen Sommerpause hat der Bundestag am 28.6.2019 das 2. Datenschutz-Anpassungs- und Umsetzungsgesetz EU (2. DSAnpUG-EU) beschlossen, der Bundesrat hat diesem Gesetz am 20.9.2019 zugestimmt. Das Artikelgesetz, welches im sog. Omnibusverfahren zahlreiche Gesetze auf Bundesebene ändert, soll zur Vereinheitlichung und Anpassung des Bundesrechts an die seit Mai 2018 geltende Datenschutz-Grundverordnung (DSGVO) beitragen.
A light-addressable potentiometric sensor (LAPS) is a field-effect-based (bio-) chemical sensor, in which a desired sensing area on the sensor surface can be defined by illumination. Light addressability can be used to visualize the concentration and spatial distribution of the target molecules, e.g., H+ ions. This unique feature has great potential for the label-free imaging of the metabolic activity of living organisms. The cultivation of those organisms needs specially tailored surface properties of the sensor. O2 plasma treatment is an attractive and promising tool for rapid surface engineering. However, the potential impacts of the technique are carefully investigated for the sensors that suffer from plasma-induced damage. Herein, a LAPS with a Ta2O5 pH-sensitive surface is successfully patterned by plasma treatment, and its effects are investigated by contact angle and scanning LAPS measurements. The plasma duration of 30 s (30 W) is found to be the threshold value, where excessive wettability begins. Furthermore, this treatment approach causes moderate plasma-induced damage, which can be reduced by thermal annealing (10 min at 300 °C). These findings provide a useful guideline to support future studies, where the LAPS surface is desired to be more hydrophilic by O2 plasma treatment.
Sensitive and rapid detection of cholera toxin subunit B using magnetic frequency mixing detection
(2019)
Cholera is a life-threatening disease caused by the cholera toxin (CT) as produced by some Vibrio cholerae serogroups. In this research we present a method which directly detects the toxin’s B subunit (CTB) in drinking water. For this purpose we performed a magnetic sandwich immunoassay inside a 3D immunofiltration column. We used two different commercially available antibodies to capture CTB and for binding to superparamagnetic beads. ELISA experiments were performed to select the antibody combination. The beads act as labels for the magnetic frequency mixing detection technique. We show that the limit of detection depends on the type of magnetic beads. A nonlinear Hill curve was fitted to the calibration measurements by means of a custom-written python software. We achieved a sensitive and rapid detection of CTB within a broad concentration range from 0.2 ng/ml to more
than 700 ng/ml.