Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (2077)
- Fachbereich Elektrotechnik und Informationstechnik (1184)
- Fachbereich Wirtschaftswissenschaften (1163)
- Fachbereich Energietechnik (1115)
- Fachbereich Chemie und Biotechnologie (912)
- Fachbereich Maschinenbau und Mechatronik (876)
- Fachbereich Luft- und Raumfahrttechnik (798)
- Fachbereich Bauingenieurwesen (711)
- IfB - Institut für Bioengineering (690)
- INB - Institut für Nano- und Biotechnologien (615)
Language
- German (5129)
- English (4929)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Italian (4)
- Spanish (3)
- Dutch (2)
Document Type
- Article (5658)
- Conference Proceeding (1650)
- Book (1082)
- Part of a Book (569)
- Bachelor Thesis (327)
- Patent (174)
- Report (102)
- Doctoral Thesis (80)
- Other (76)
- Administrative publication (76)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (23)
Zugriffsart
- campus (2151)
- weltweit (1881)
- bezahl (773)
- fachbereichsweit (FB4) (34)
Eigenkapitalkosten sind eine wesentliche Determinante bei der Wertbestimmung von Unternehmen und Unternehmensteilen. Die Eigenkapitalkosten werden regelmäßig mittels des CAPM bestimmt. Für sog. konzerninterne Routinefunktionen mit geringem Risiko stellt diese Bestimmung mittels CAPM ein Problem dar, da börsennotierte Peergroups für eine zuverlässige Bestimmung des Beta-Faktors meist nicht identifizierbar sind. Damit ergeben sich bei Bewertungen von Routineunternehmen Unsicherheiten und Konfliktpotenzial in steuerlichen Betriebsprüfungen. Dieser Beitrag gibt einen Überblick der in der Praxis genutzten Ansätze und stellt eine theoretische Fundierung zur Bestimmung der Eigenkapitalkosten von konzerninternen Routinefunktionen vor. Dabei wird verdeutlicht, dass Eigenkapitalkosten von konzerninternen Routinefunktionen nicht denen des Gesamtkonzerns entsprechen und Praktikeransätze eine grundsätzliche Berechtigung besitzen.
During the Covid-19 pandemic, vocational colleges, universities of applied science and technical universities often had to cancel laboratory sessions requiring students’ attendance. These above of all are of decisive importance in order to give learners an understanding of theory through practical work.This paper is a contribution to the implementation of distance learning for laboratory work applicable for several upper secondary educational facilities. Its aim is to provide a paradigm for hybrid teaching to analyze and control a non-linear system depicted by a tank model. For this reason, we redesign a full series of laboratory sessions on the basis of various challenges. Thus, it is suitable to serve different reference levels of the European Qualifications Framework (EQF).We present problem-based learning through online platforms to compensate the lack of a laboratory learning environment. With a task deduced from their future profession, we give students the opportunity to develop own solutions in self-defined time intervals. A requirements specification provides the framework conditions in terms of time and content for students having to deal with the challenges of the project in a self-organized manner with regard to inhomogeneous previous knowledge. If the concept of Complete Action is introduced in classes before, they will automatically apply it while executing the project.The goal is to combine students’ scientific understanding with a procedural knowledge. We suggest a series of remote laboratory sessions that combine a problem formulation from the subject area of Measurement, Control and Automation Technology with a project assignment that is common in industry by providing extracts from a requirements specification.
Project work and inter disciplinarity are integral parts of today's engineering work. It is therefore important to incorporate these aspects into the curriculum of academic studies of engineering. At the faculty of Electrical Engineering and Information Technology an interdisciplinary project is part of the bachelor program to address these topics. Since the summer term 2020 most courses changed to online mode during the Covid-19 crisis including the interdisciplinary projects. This online mode introduces additional challenges to the execution of the projects, both for the students as well as for the lecture. The challenges, but also the risks and chances of this kind of project courses are subject of this paper, based on five different interdisciplinary projects
Cardiopulmonary bypass (CPB) is a standard technique for cardiac surgery, but comes with the risk of severe neurological complications (e.g. stroke) caused by embolisms and/or reduced cerebral perfusion. We report on an aortic cannula prototype design (optiCAN) with helical outflow and jet-splitting dispersion tip that could reduce the risk of embolic events and restores cerebral perfusion to 97.5% of physiological flow during CPB in vivo, whereas a commercial curved-tip cannula yields 74.6%. In further in vitro comparison, pressure loss and hemolysis parameters of optiCAN remain unaffected. Results are reproducibly confirmed in silico for an exemplary human aortic anatomy via computational fluid dynamics (CFD) simulations. Based on CFD simulations, we firstly show that optiCAN design improves aortic root washout, which reduces the risk of thromboembolism. Secondly, we identify regions of the aortic intima with increased risk of plaque release by correlating areas of enhanced plaque growth and high wall shear stresses (WSS). From this we propose another easy-to-manufacture cannula design (opti2CAN) that decreases areas burdened by high WSS, while preserving physiological cerebral flow and favorable hemodynamics. With this novel cannula design, we propose a cannulation option to reduce neurological complications and the prevalence of stroke in high-risk patients after CPB.
Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential.
In positron emission tomography improving time, energy and spatial detector resolutions and using Compton kinematics introduces the possibility to reconstruct a radioactivity distribution image from scatter coincidences, thereby enhancing image quality. The number of single scattered coincidences alone is in the same order of magnitude as true coincidences. In this work, a compact Compton camera module based on monolithic scintillation material is investigated as a detector ring module. The detector interactions are simulated with Monte Carlo package GATE. The scattering angle inside the tissue is derived from the energy of the scattered photon, which results in a set of possible scattering trajectories or broken line of response. The Compton kinematics collimation reduces the number of solutions. Additionally, the time of flight information helps localize the position of the annihilation. One of the questions of this investigation is related to how the energy, spatial and temporal resolutions help confine the possible annihilation volume. A comparison of currently technically feasible detector resolutions (under laboratory conditions) demonstrates the influence on this annihilation volume and shows that energy and coincidence time resolution have a significant impact. An enhancement of the latter from 400 ps to 100 ps leads to a smaller annihilation volume of around 50%, while a change of the energy resolution in the absorber layer from 12% to 4.5% results in a reduction of 60%. The inclusion of single tissue-scattered data has the potential to increase the sensitivity of a scanner by a factor of 2 to 3 times. The concept can be further optimized and extended for multiple scatter coincidences and subsequently validated by a reconstruction algorithm.