Article
Refine
Year of publication
Document Type
- Article (330) (remove)
Keywords
- Haustechnik (2)
- Heizung (2)
- Klimatechnik (2)
- Lüftung (2)
- Lüftungstechnik (2)
- Abluft (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Anammox (1)
- Anschlüsse an Stahlbeton (1)
- Biogas (1)
- Brandfall (1)
- Circular bioeconomy (1)
- EN 1993-1-2 (1)
- Eingespannte Stützen und Träger (1)
- Einspanntiefen (1)
- Forschung, pränormativ (1)
- Hazard assessment (1)
- Landslide tsunamis (1)
- Large scale tests (1)
Institute
- Fachbereich Bauingenieurwesen (330) (remove)
Geotechnik
(2007)
Geotechnik
(2007)
This paper proposes an approach to the choice and evaluation of engineering models with the aid of a typical application in geotechnics. An important issue in the construction of shallow tunnels, especially in weak ground conditions, is the tunnel face stability. Various theoretical and numerical models for predicting the necessary support pressure have been put forth in the literature. In this paper, we combine laboratory experiments performed at the University of Innsbruck with current methods of uncertainty and sensitivity analysis for assessing adequacy, predictive power and robustness of the models. The major issues are the handling of the twofold uncertainty of test results and of model predictions as well as the decision about what are the influential input parameters.
Anwendung von GFK in Japan.
(2005)
Seßlestalbrücke - Verbundbrücke mit einteiligem Querschnitt / Wanzek, Thorsten; Gossla, Ulrich
(2003)
This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants.
Die neu erschienenen „Empfehlungen zum Einsatz von Verkehrsnachfragemodellen für den Personenverkehr“ liefern erstmals als Empfehlungspapier der Forschungsgesellschaft für Straßen- und Verkehrswesen einen umfassenden Überblick zu den verschiedenen Aspekten der Modellierung und geben dem Fachplaner konkrete Hilfestellung für die Konzeption von Nachfragemodellen. Das Empfehlungspapier zielt unter anderem darauf ab, die Erwartungen und das Anspruchsniveau in Hinblick auf Sachgerechtigkeit der Modelle, die erzielbare Modellqualität und den Detaillierungsgrad der Modellaussagen zu harmonisieren.
Taxiverkehr in Deutschland
(2008)
Zur Anwendung des Eurocode 3 Teil 1-2 für die Heißbemessung und Anregungen für dessen Novellierung
(2016)
Die Eurocodes werden bis zum Jahr 2020 im Europäischen Komitee für Normung (CEN), Technisches Komitee TC 250, überarbeitet. In Vorbereitung auf die Eurocode-Novellierung haben engagierte Ingenieure im Rahmen der Initiative PraxisRegeln Bau (PRB) die für die praktische Anwendung häufig genutzten Teile des Eurocode 3 untersucht. Mit dem Ziel, die Praxistauglichkeit des Eurocode 3 für die Heißbemessung zu verbessern, wurden die bestehende Norm EN 1993 Teil 1-2 insbesondere in Bezug auf die Anwenderfreundlichkeit analysiert und Vorschläge für die europäische Novellierung erarbeitet. Die Analysen zeigen, dass durch Umstrukturierungen und durch die Einführung von Tabellen die Verständlichkeit und Anwenderfreundlichkeit der Regeln für die Heißbemessung bedeutend erhöht werden können.
Beurteilung der Ausbaunotwendigkeit von Eisenbahn-Streckenabschnitten - ein anspruchsloses Verfahren
(2007)
Different analytical approaches exist to describe the structural substance or wear reserve of sewer systems. The aim is to convert engineering assessments of often complex defect patterns into computational algorithms and determine a substance class for a sewer section or manhole. This analytically determined information is essential for strategic rehabilitation planning processes up to network level, as it corresponds to the most appropriate rehabilitation type and can thus provide decision-making support. Current calculation methods differ clearly from each other in parts, so that substance classes determined by the different approaches are only partially comparable with each other. The objective of the German R&D cooperation project ‘SubKanS’ is to develop a methodology for classifying the specific defect patterns resulting from the interaction of all the individual defects, and their severities and locations. The methodology takes into account the structural substance of sewer sections and manholes, based on real data and theoretical considerations analogous to the condition classification of individual defects. The result is a catalogue of defect patterns and characteristics, as well as associated structural substance classifications of sewer systems (substance classes). The methodology for sewer system substance classification is developed so that the classification of individual defects can be transferred into a substance class of the sewer section or manhole, eventually taking into account further information (e.g. pipe material, nominal diameter, etc.). The result is a validated methodology for automated sewer system substance classification.
Abfallentsorgung und Geruchsemissionen. Tl.2. Minderungsmaßnahmen / Frechen, F. B.; Kettern, J. T.
(1995)
Stützen und Träger aus Stahlprofilen können in Fundamente oder Wände aus Stahlbeton einbetoniert werden. Diese Anschlüsse wirken in der Regel wie Einspannungen, die eine ausreichende Einspanntiefe erfordern. Im Folgenden wird eine verallgemeinerte Berechnungsmethode für in Stahlbetonkonstruktionen eingespannte Stahlprofile aus gewalzten I-Profilen, geschweißten I-Profilen, runden Hohlprofilen, eckigen Hohlprofilen und einzelligen Kastenquerschnitten vorgestellt. Für Beanspruchungen infolge einachsiger Biegung um die starke und schwache Profilachse werden der profilabhängige Ansatz der Betondruckspannungen im Einspannbereich und die Ermittlung der Einspanntiefe behandelt. Unter Berücksichtigung der Normalkraft werden an den maßgebenden Stellen Tragfähigkeitsnachweise für die Stahlprofile geführt. Als Ergänzung zu den Berechnungsformeln werden Bemessungshilfen zur Verfügung gestellt, die die Wahl der mitwirkenden Breiten und der Einspanntiefen erleichtert.
Various models have been proposed for the prediction of the necessary support pressure at the face of a shallow tunnel. To assess their quality, the collapse of a tunnel face was modelled with small-scale model tests at single gravity. The development of the failure mechanism and the support force at the face in dry sand were investigated. The observed displacement patterns show a negligible influence of overburden on the extent and evolution of the failure zone. The latter is significantly influenced, though, by the initial density of the sand: in dense sand a chimney-wedge-type collapse mechanism developed, which propagated towards the soil surface. Initially, loose sand did not show any discrete collapse mechanism. The necessary support force was neither influenced by the overburden nor the initial density. A comparison with quantitative predictions by several theoretical models showed that the measured necessary support pressure is overestimated by most of the models. Those by Vermeer/Ruse and Léca/Dormieux showed the best agreement to the measurements.
As part of a novel approach to automatic sewer inspection, this paper presents a robust algorithm for automatic flow line detection. A large image repository is obtained from about 50,000 m sewers to represent the high variability of real world sewer systems. Automatic image processing combines Canny edge detection, Hough transform for straight lines and cost minimization using Dijkstra's shortest path algorithm. Assuming that flow lines are mostly smoothly connected horizontal structures, piecewise flow line delineation is reduced to a process of selecting adjacent line candidates. Costs are derived from the gap between adjacent candidates and their reliability. A single parameter α enables simple control of the algorithm. The detected flow line may precisely follow the segmented edges (α = 0.0) or minimize gaps at joints (α = 1.0). Both, manual and ground truth-based analysis indicate that α = 0.8 is optimal and independent of the sewer's material. The algorithm forms an essential step to further automation of sewer inspection.
Schalung und Gerüste
(2006)
Schalung und Gerüste
(2006)