Article
Refine
Year of publication
- 2022 (80) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (34)
- IfB - Institut für Bioengineering (23)
- Fachbereich Chemie und Biotechnologie (14)
- INB - Institut für Nano- und Biotechnologien (13)
- Fachbereich Energietechnik (8)
- Fachbereich Elektrotechnik und Informationstechnik (5)
- Fachbereich Luft- und Raumfahrttechnik (5)
- Fachbereich Maschinenbau und Mechatronik (4)
- ECSM European Center for Sustainable Mobility (3)
- Fachbereich Bauingenieurwesen (3)
Language
- English (80) (remove)
Document Type
- Article (80) (remove)
Keywords
- Chemometrics (2)
- Earthquake (2)
- Heparin (2)
- NMR spectroscopy (2)
- biosensors (2)
- damage (2)
- Actuator disk modelling (1)
- Algal Turf Scrubber (1)
- Algal–bacterial bioflm (1)
- Alkalihalobacillus okhensis (1)
- Alzheimer's disease (1)
- Artificial intelligence (1)
- Assembly (1)
- Automated driving (1)
- Automotive application (1)
- BET (1)
- Behaviour factor q (1)
- Benchmark (1)
- Biocomposites (1)
- Biogas (1)
- Biomass (1)
- Biomechanical simulation (1)
- Bootstrapping (1)
- Boundary integral equations (1)
- Brake set-up (1)
- Brake test (1)
- CAV (1)
- CFD propeller simulation (1)
- Categorial variable (1)
- Cementoblast (1)
- Circular bioeconomy (1)
- Civil engineering (1)
- Clinical decision support systems (1)
- Collective risk model (1)
- Compression (1)
- Concomitant (1)
- Conductive boundary condition (1)
- Crude heparin (1)
- Data-driven models (1)
- Decoupling (1)
- Drinfeld modules (1)
- Dynamic simulation (1)
- ES-FEM (1)
- Empirical process (1)
- Explainability (1)
- FS-FEM (1)
- Feature selection (1)
- Finite element analysis (1)
- Forces (1)
- Fracture classification (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freight rail (1)
- Gamification (1)
- Genetic algorithm (1)
- Haemodialysis (1)
- Handbike (1)
- Hazard assessment (1)
- Heterostructure (1)
- Higher derivations (1)
- INSYSME (1)
- IR spectroscopy (1)
- Image Reconstruction (1)
- Imaging (1)
- In-plane performance, isolation (1)
- Incident analysis (1)
- Independence test (1)
- Infill wall design (1)
- Inorganic ions (1)
- Instructional design (1)
- Interstellar objects (1)
- Inverse spectral problem (1)
- Ions (1)
- Justice (1)
- Landslide tsunamis (1)
- Large scale tests (1)
- Level system (1)
- Lidar (1)
- Linear elastic analysis (1)
- Machine learning (1)
- Masonry infill (1)
- Measurement models (1)
- Measurement uncertainty (1)
- Mechanotransduction (1)
- Medical AI (1)
- Metascintillator (1)
- Methane (1)
- Microcirculation (1)
- Mild cognitive impairment (1)
- Missions (1)
- Modelling (1)
- Modern constructions (1)
- Molecular modelling (1)
- Molecular weight determination (1)
- Molten salt receiver system (1)
- Molten salt solar tower (1)
- Monte Carlo Tree Search (1)
- Morphing (1)
- Multiple TOF kernels (1)
- Myocardial infarction and cardiac death (1)
- NMR (1)
- Natural fibres (1)
- Normative standards (1)
- Numerical modelling (1)
- Overland flow (1)
- PLS-regression (1)
- Paralympic sport (1)
- Periods (1)
- Polymer-matrix composites (1)
- Probability distribution mapping (1)
- Propeller aerodynamics (1)
- Propeller performance (1)
- Proper Orthogonal Decomposition (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- Q-criterion (1)
- Quality control (1)
- Quantum chemistry (1)
- Reinforced concrete frame (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Rotator cuff (1)
- S-FEM (1)
- Seismic design (1)
- Seismic loading (1)
- Self-driving (1)
- Shoulder (1)
- Solitary waves (1)
- Standardization (1)
- Stress concentrations (1)
- Structural design (1)
- TOF PET (1)
- Tension (1)
- Train composition (1)
- Trajectories (1)
- Transcendence (1)
- Transient flux distribution (1)
- Transmission eigenvalues (1)
- Two-phase modelling (1)
- USP (1)
- Unreinforced masonry buildings (1)
- User study (1)
- Vasomotions (1)
- Virtual reality (1)
- additive manufacturing (1)
- adipose-derived stromal cells (ASCs) (1)
- aminooctanethiol (1)
- anaesthetic complications (1)
- anisotropy (1)
- aortic perfusion (1)
- aseptic parameters (1)
- atomic layer deposition (1)
- automated vehicles (1)
- bacterial cellulose (1)
- batteries and fuel cells (1)
- bi-enzyme biosensor (1)
- biaxial tensile experiment (1)
- biocompatible materials (1)
- biodegradable electronic devices (1)
- biopharmaceutical production process (1)
- biopotential electrodes (1)
- body imaging at 7 T MRI (1)
- bootstrap (1)
- borefields (1)
- borehole disposal (1)
- capacitive field-effect sensor (1)
- capacitive field-effect sensors (1)
- capacitive model (1)
- carbon electrodes (1)
- cell aerosolization (1)
- cell atomization (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- coculture (1)
- cognitive impairment (1)
- coherent structures (1)
- computational fluid dynamics analysis (1)
- connected automated vehicles (1)
- constitutive modeling (1)
- correlation (1)
- crystallization (1)
- dental trauma (1)
- detergent protease (1)
- dialysis (1)
- difficult airway (1)
- disposal facility (1)
- distorted element (1)
- double-lumen tube intubation (1)
- downstream processing design (1)
- electrolyte-insulator-semiconductor capacitors (1)
- electrospinning (1)
- endoluminal (1)
- energy (1)
- enzyme-logic gate (1)
- exopolysaccharides (1)
- experiment quality (1)
- experimental evaluation (1)
- extracorporeal membrane oxygenation (1)
- eye movement modelling examples (1)
- fibers (1)
- field-effect sensor (1)
- force generation (1)
- forehead EEG (1)
- frequency mixing magnetic detection (1)
- fused filament fabrication (1)
- gaseous hydrogen peroxide (1)
- geological disposal (1)
- geothermal (1)
- glucose (1)
- gold nanoparticles (1)
- halotolerant protease (1)
- high-alkaline subtilisin (1)
- high-intensity exercise (1)
- hybrid model validation (1)
- hydraulic modelling (1)
- hyperelastic (1)
- ignition (1)
- impedance spectroscopy (1)
- in-ear EEG (1)
- irradiation (1)
- limit analysis (1)
- magnetic nanoparticles (1)
- magnetic sensors (1)
- microplasma (1)
- microwave (MW) plasma (1)
- model performance (1)
- multi-sensing platform (1)
- muscle fascicle behavior (1)
- nanoparticle coverage (1)
- non-simplex S-FEM elements (1)
- nuclear waste (1)
- oxidative stable protease (1)
- pH sensors (1)
- penicillinase (1)
- performance testing (1)
- plasma jet (1)
- polyetheretherketone (1)
- porous materials (1)
- prebiotic (1)
- pullulan (1)
- rapid tooling (1)
- reliability of structures (1)
- retention time (1)
- retinal vessels (1)
- sEMG (1)
- shakedown analysis (1)
- simulation (1)
- sizing (1)
- smooth muscle contraction (1)
- spore kill rate (1)
- sterility (1)
- stochastic programming (1)
- strain energy function (1)
- survival (1)
- t-modules (1)
- tendon rupture (1)
- thermal dose (1)
- tissue temperature (1)
- tobacco mosaic virus (TMV) (1)
- transmit antenna arrays (1)
- tri-lineage differentiation (1)
- twin-fluid atomizer (1)
- ultrasound imaging (1)
- ultrathin gate insulators (1)
- urease (1)
- video learning (1)
- videolaryngoscopy (1)
- virgin passive (1)
- viscoelasticity (1)
- walking gait (1)
This paper compares several blade element theory (BET) method-based propeller simulation tools, including an evaluation against static propeller ground tests and high-fidelity Reynolds-Average Navier Stokes (RANS) simulations. Two proprietary propeller geometries for paraglider applications are analysed in static and flight conditions. The RANS simulations are validated with the static test data and used as a reference for comparing the BET in flight conditions. The comparison includes the analysis of varying 2D aerodynamic airfoil parameters and different induced velocity calculation methods. The evaluation of the BET propeller simulation tools shows the strength of the BET tools compared to RANS simulations. The RANS simulations underpredict static experimental data within 10% relative error, while appropriate BET tools overpredict the RANS results by 15–20% relative error. A variation in 2D aerodynamic data depicts the need for highly accurate 2D data for accurate BET results. The nonlinear BET coupled with XFOIL for the 2D aerodynamic data matches best with RANS in static operation and flight conditions. The novel BET tool PropCODE combines both approaches and offers further correction models for highly accurate static and flight condition results.
Altered gastrocnemius contractile behavior in former achilles tendon rupture patients during walking
(2022)
Achilles tendon rupture (ATR) remains associated with functional limitations years after injury. Architectural remodeling of the gastrocnemius medialis (GM) muscle is typically observed in the affected leg and may compensate force deficits caused by a longer tendon. Yet patients seem to retain functional limitations during—low-force—walking gait. To explore the potential limits imposed by the remodeled GM muscle-tendon unit (MTU) on walking gait, we examined the contractile behavior of muscle fascicles during the stance phase. In a cross-sectional design, we studied nine former patients (males; age: 45 ± 9 years; height: 180 ± 7 cm; weight: 83 ± 6 kg) with a history of complete unilateral ATR, approximately 4 years post-surgery. Using ultrasonography, GM tendon morphology, muscle architecture at rest, and fascicular behavior were assessed during walking at 1.5 m⋅s–1 on a treadmill. Walking patterns were recorded with a motion capture system. The unaffected leg served as control. Lower limbs kinematics were largely similar between legs during walking. Typical features of ATR-related MTU remodeling were observed during the stance sub-phases corresponding to series elastic element (SEE) lengthening (energy storage) and SEE shortening (energy release), with shorter GM fascicles (36 and 36%, respectively) and greater pennation angles (8° and 12°, respectively). However, relative to the optimal fascicle length for force production, fascicles operated at comparable length in both legs. Similarly, when expressed relative to optimal fascicle length, fascicle contraction velocity was not different between sides, except at the time-point of peak series elastic element (SEE) length, where it was 39 ± 49% lower in the affected leg. Concomitantly, fascicles rotation during contraction was greater in the affected leg during the whole stance-phase, and architectural gear ratios (AGR) was larger during SEE lengthening. Under the present testing conditions, former ATR patients had recovered a relatively symmetrical walking gait pattern. Differences in seen AGR seem to accommodate the profound changes in MTU architecture, limiting the required fascicle shortening velocity. Overall, the contractile behavior of the GM fascicles does not restrict length- or velocity-dependent force potentials during this locomotor task.
Advances in polymer science have significantly increased polymer applications in life sciences. We report the use of free-standing, ultra-thin polydimethylsiloxane (PDMS) membranes, called CellDrum, as cell culture substrates for an in vitro wound model. Dermal fibroblast monolayers from 28- and 88-year-old donors were cultured on CellDrums. By using stainless steel balls, circular cell-free areas were created in the cell layer (wounding). Sinusoidal strain of 1 Hz, 5% strain, was applied to membranes for 30 min in 4 sessions. The gap circumference and closure rate of un-stretched samples (controls) and stretched samples were monitored over 4 days to investigate the effects of donor age and mechanical strain on wound closure. A significant decrease in gap circumference and an increase in gap closure rate were observed in trained samples from younger donors and control samples from older donors. In contrast, a significant decrease in gap closure rate and an increase in wound circumference were observed in the trained samples from older donors. Through these results, we propose the model of a cell monolayer on stretchable CellDrums as a practical tool for wound healing research. The combination of biomechanical cell loading in conjunction with analyses such as gene/protein expression seems promising beyond the scope published here.
Analysis and computation of the transmission eigenvalues with a conductive boundary condition
(2022)
We provide a new analytical and computational study of the transmission eigenvalues with a conductive boundary condition. These eigenvalues are derived from the scalar inverse scattering problem for an inhomogeneous material with a conductive boundary condition. The goal is to study how these eigenvalues depend on the material parameters in order to estimate the refractive index. The analytical questions we study are: deriving Faber–Krahn type lower bounds, the discreteness and limiting behavior of the transmission eigenvalues as the conductivity tends to infinity for a sign changing contrast. We also provide a numerical study of a new boundary integral equation for computing the eigenvalues. Lastly, using the limiting behavior we will numerically estimate the refractive index from the eigenvalues provided the conductivity is sufficiently large but unknown.
On the basis of independent and identically distributed bivariate random vectors, where the components are categorial and continuous variables, respectively, the related concomitants, also called induced order statistic, are considered. The main theoretical result is a functional central limit theorem for the empirical process of the concomitants in a triangular array setting. A natural application is hypothesis testing. An independence test and a two-sample test are investigated in detail. The fairly general setting enables limit results under local alternatives and bootstrap samples. For the comparison with existing tests from the literature simulation studies are conducted. The empirical results obtained confirm the theoretical findings.
With proven impact of statistical fracture analysis on fracture classifications, it is desirable to minimize the manual work and to maximize repeatability of this approach. We address this with an algorithm that reduces the manual effort to segmentation, fragment identification and reduction. The fracture edge detection and heat map generation are performed automatically. With the same input, the algorithm always delivers the same output. The tool transforms one intact template consecutively onto each fractured specimen by linear least square optimization, detects the fragment edges in the template and then superimposes them to generate a fracture probability heat map.
We hypothesized that the algorithm runs faster than the manual evaluation and with low (< 5 mm) deviation. We tested the hypothesis in 10 fractured proximal humeri and found that it performs with good accuracy (2.5 mm ± 2.4 mm averaged Euclidean distance) and speed (23 times faster). When applied to a distal humerus, a tibia plateau, and a scaphoid fracture, the run times were low (1–2 min), and the detected edges correct by visual judgement. In the geometrically complex acetabulum, at a run time of 78 min some outliers were considered acceptable. An automatically generated fracture probability heat map based on 50 proximal humerus fractures matches the areas of high risk of fracture reported in medical literature.
Such automation of the fracture analysis method is advantageous and could be extended to reduce the manual effort even further.
Introduction
In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration.
Materials and methods
Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer’s classification was used to analyse the fractures.
Results
In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities.
Conclusion
A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education.
This study reviews the practice of brake tests in freight railways, which is time consuming and not suitable to detect certain failure types. Public incident reports are analysed to derive a reasonable brake test hardware and communication architecture, which aims to provide automatic brake tests at lower cost than current solutions. The proposed solutions relies exclusively on brake pipe and brake cylinder pressure sensors, a brake release position switch as well as radio communication via standard protocols. The approach is embedded in the Wagon 4.0 concept, which is a holistic approach to a smart freight wagon. The reduction of manual processes yields a strong incentive due to high savings in manual
labour and increased productivity.
Chromatography is the workhorse of biopharmaceutical downstream processing because it can selectively enrich a target product while removing impurities from complex feed streams. This is achieved by exploiting differences in molecular properties, such as size, charge and hydrophobicity (alone or in different combinations). Accordingly, many parameters must be tested during process development in order to maximize product purity and recovery, including resin and ligand types, conductivity, pH, gradient profiles, and the sequence of separation operations. The number of possible experimental conditions quickly becomes unmanageable. Although the range of suitable conditions can be narrowed based on experience, the time and cost of the work remain high even when using high-throughput laboratory automation. In contrast, chromatography modeling using inexpensive, parallelized computer hardware can provide expert knowledge, predicting conditions that achieve high purity and efficient recovery. The prediction of suitable conditions in silico reduces the number of empirical tests required and provides in-depth process understanding, which is recommended by regulatory authorities. In this article, we discuss the benefits and specific challenges of chromatography modeling. We describe the experimental characterization of chromatography devices and settings prior to modeling, such as the determination of column porosity. We also consider the challenges that must be overcome when models are set up and calibrated, including the cross-validation and verification of data-driven and hybrid (combined data-driven and mechanistic) models. This review will therefore support researchers intending to establish a chromatography modeling workflow in their laboratory.
Purpose: A precise determination of the corneal diameter is essential for the diagnosis of various ocular diseases, cataract and refractive surgery as well as for the selection and fitting of contact lenses. The aim of this study was to investigate the agreement between two automatic and one manual method for corneal diameter determination and to evaluate possible diurnal variations in corneal diameter.
Patients and Methods: Horizontal white-to-white corneal diameter of 20 volunteers was measured at three different fixed times of a day with three methods: Scheimpflug method (Pentacam HR, Oculus), placido based topography (Keratograph 5M, Oculus) and manual method using an image analysis software at a slitlamp (BQ900, Haag-Streit).
Results: The two-factorial analysis of variance could not show a significant effect of the different instruments (p = 0.117), the different time points (p = 0.506) and the interaction between instrument and time point (p = 0.182). Very good repeatability (intraclass correlation coefficient ICC, quartile coefficient of dispersion QCD) was found for all three devices. However, manual slitlamp measurements showed a higher QCD than the automatic measurements with the Keratograph 5M and the Pentacam HR at all measurement times.
Conclusion: The manual and automated methods used in the study to determine corneal diameter showed good agreement and repeatability. No significant diurnal variations of corneal diameter were observed during the period of time studied.