Refine
Year of publication
- 2024 (10)
- 2023 (36)
- 2022 (48)
- 2021 (55)
- 2020 (52)
- 2019 (69)
- 2018 (67)
- 2017 (67)
- 2016 (54)
- 2015 (70)
- 2014 (65)
- 2013 (65)
- 2012 (72)
- 2011 (82)
- 2010 (72)
- 2009 (85)
- 2008 (61)
- 2007 (57)
- 2006 (75)
- 2005 (48)
- 2004 (85)
- 2003 (57)
- 2002 (55)
- 2001 (54)
- 2000 (65)
- 1999 (40)
- 1998 (39)
- 1997 (36)
- 1996 (32)
- 1995 (19)
- 1994 (13)
- 1993 (19)
- 1992 (13)
- 1991 (12)
- 1990 (17)
- 1989 (21)
- 1988 (22)
- 1987 (26)
- 1986 (7)
- 1985 (10)
- 1984 (9)
- 1983 (6)
- 1982 (24)
- 1981 (16)
- 1980 (30)
- 1979 (20)
- 1978 (27)
- 1977 (13)
- 1976 (16)
- 1975 (14)
- 1974 (4)
- 1973 (3)
- 1972 (6)
- 1971 (1)
- 1969 (1)
- 1968 (2)
- 1967 (1)
Document Type
- Article (1578)
- Conference Proceeding (233)
- Book (96)
- Part of a Book (58)
- Doctoral Thesis (27)
- Patent (17)
- Report (15)
- Other (8)
- Habilitation (4)
- Lecture (3)
- Preprint (3)
- Course Material (1)
- Review (1)
- Talk (1)
Keywords
- Biosensor (25)
- Finite-Elemente-Methode (16)
- CAD (15)
- civil engineering (14)
- Bauingenieurwesen (13)
- Einspielen <Werkstoff> (13)
- shakedown analysis (9)
- FEM (6)
- Limit analysis (6)
- Shakedown analysis (6)
- limit analysis (6)
- Clusterion (5)
- Air purification (4)
- Einspielanalyse (4)
- Hämoglobin (4)
- Lipopolysaccharide (4)
- Luftreiniger (4)
- Natural language processing (4)
- Plasmacluster ion technology (4)
- Raumluft (4)
Institute
- Fachbereich Medizintechnik und Technomathematik (2045) (remove)
Λ, Image production in e+e- annihilation at 33 GeV centre of mass energy. TASSO Collaboration
(1981)
π0 production by e+e− annihilation at 14 and 34 GeV c.m. energy . TASSO Collaboration
(1982)
The light-addressable potentiometric sensor (LAPS) and scanning photo-induced impedance microscopy (SPIM) are two closely related methods to visualise the distributions of chemical species and impedance, respectively, at the interface between the sensing surface and the sample solution. They both have the same field-effect structure based on a semiconductor, which allows spatially resolved and label-free measurement of chemical species and impedance in the form of a photocurrent signal generated by a scanning light beam. In this article, the principles and various operation modes of LAPS and SPIM, functionalisation of the sensing surface for measuring various species, LAPS-based chemical imaging and high-resolution sensors based on silicon-on-sapphire substrates are described and discussed, focusing on their technical details and prospective applications.
For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated.