Refine
Year of publication
Institute
- Fachbereich Medizintechnik und Technomathematik (1941)
- Fachbereich Elektrotechnik und Informationstechnik (1153)
- Fachbereich Wirtschaftswissenschaften (1121)
- Fachbereich Energietechnik (1067)
- Fachbereich Chemie und Biotechnologie (899)
- Fachbereich Maschinenbau und Mechatronik (817)
- Fachbereich Luft- und Raumfahrttechnik (770)
- Fachbereich Bauingenieurwesen (665)
- IfB - Institut für Bioengineering (630)
- INB - Institut für Nano- und Biotechnologien (586)
- Fachbereich Gestaltung (349)
- Solar-Institut Jülich (335)
- Fachbereich Architektur (186)
- ECSM European Center for Sustainable Mobility (124)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (68)
- Nowum-Energy (65)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (62)
- Institut fuer Angewandte Polymerchemie (36)
- Sonstiges (24)
- IBB - Institut für Baustoffe und Baukonstruktionen (21)
- Kommission für Forschung und Entwicklung (20)
- Freshman Institute (19)
- Verwaltung (11)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (4)
- FH Aachen (4)
- IMP - Institut für Mikrowellen- und Plasmatechnik (4)
- IaAM - Institut für angewandte Automation und Mechatronik (4)
- Kommission für Planung und Finanzen (3)
- Senat (2)
- Datenverarbeitungszentrale (1)
- Digitalisierung in Studium & Lehre (1)
Has Fulltext
- no (9351) (remove)
Language
Document Type
- Article (5509)
- Conference Proceeding (1448)
- Book (1064)
- Part of a Book (572)
- Patent (177)
- Bachelor Thesis (170)
- Report (83)
- Conference: Meeting Abstract (82)
- Doctoral Thesis (82)
- Other (67)
Keywords
- Illustration (10)
- Nachhaltigkeit (10)
- Corporate Design (9)
- Erscheinungsbild (8)
- Gamification (8)
- Redesign (7)
- Animation (6)
- Datenschutz (6)
- Deutschland (6)
- Digitalisierung (6)
This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains.
Purpose: A precise determination of the corneal diameter is essential for the diagnosis of various ocular diseases, cataract and refractive surgery as well as for the selection and fitting of contact lenses. The aim of this study was to investigate the agreement between two automatic and one manual method for corneal diameter determination and to evaluate possible diurnal variations in corneal diameter.
Patients and Methods: Horizontal white-to-white corneal diameter of 20 volunteers was measured at three different fixed times of a day with three methods: Scheimpflug method (Pentacam HR, Oculus), placido based topography (Keratograph 5M, Oculus) and manual method using an image analysis software at a slitlamp (BQ900, Haag-Streit).
Results: The two-factorial analysis of variance could not show a significant effect of the different instruments (p = 0.117), the different time points (p = 0.506) and the interaction between instrument and time point (p = 0.182). Very good repeatability (intraclass correlation coefficient ICC, quartile coefficient of dispersion QCD) was found for all three devices. However, manual slitlamp measurements showed a higher QCD than the automatic measurements with the Keratograph 5M and the Pentacam HR at all measurement times.
Conclusion: The manual and automated methods used in the study to determine corneal diameter showed good agreement and repeatability. No significant diurnal variations of corneal diameter were observed during the period of time studied.
Implikationen der Digitalisierung für den Finanzbereich der Unternehmung und das Rollenbild des CFO
(2017)