Refine
Year of publication
- 2024 (59)
- 2023 (237)
- 2022 (286)
- 2021 (282)
- 2020 (227)
- 2019 (377)
- 2018 (255)
- 2017 (258)
- 2016 (268)
- 2015 (301)
- 2014 (286)
- 2013 (299)
- 2012 (310)
- 2011 (323)
- 2010 (328)
- 2009 (360)
- 2008 (310)
- 2007 (312)
- 2006 (330)
- 2005 (303)
- 2004 (323)
- 2003 (254)
- 2002 (250)
- 2001 (221)
- 2000 (245)
- 1999 (236)
- 1998 (242)
- 1997 (220)
- 1996 (202)
- 1995 (192)
- 1994 (174)
- 1993 (154)
- 1992 (144)
- 1991 (100)
- 1990 (108)
- 1989 (111)
- 1988 (104)
- 1987 (105)
- 1986 (81)
- 1985 (84)
- 1984 (75)
- 1983 (70)
- 1982 (57)
- 1981 (54)
- 1980 (61)
- 1979 (58)
- 1978 (52)
- 1977 (32)
- 1976 (30)
- 1975 (28)
- 1974 (17)
- 1973 (12)
- 1972 (17)
- 1971 (11)
- 1970 (2)
- 1969 (2)
- 1968 (2)
- 1967 (1)
- 1963 (1)
- 1925 (1)
Document Type
- Article (5587)
- Conference Proceeding (1619)
- Book (1078)
- Part of a Book (548)
- Bachelor Thesis (297)
- Patent (172)
- Report (100)
- Doctoral Thesis (78)
- Other (77)
- Administrative publication (76)
- Part of Periodical (63)
- Lecture (30)
- Master's Thesis (20)
- Contribution to a Periodical (19)
- Review (17)
- Diploma Thesis (15)
- Working Paper (13)
- Course Material (9)
- Talk (7)
- Study Thesis (5)
Language
- German (5013)
- English (4801)
- Russian (14)
- Portuguese (6)
- Multiple languages (5)
- Spanish (3)
- nld (2)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Illustration (21)
- Studien- und Prüfungsordnung (21)
- Aachen / Fachhochschule Aachen (20)
- Änderungsordnung (20)
- Blitzschutz (18)
- Corporate Design (17)
- Elektromobilität (17)
- CAD (16)
- Finite-Elemente-Methode (16)
- Fotografie (16)
- civil engineering (14)
Institute
- Fachbereich Medizintechnik und Technomathematik (2052)
- Fachbereich Elektrotechnik und Informationstechnik (1150)
- Fachbereich Wirtschaftswissenschaften (1138)
- Fachbereich Energietechnik (1104)
- Fachbereich Maschinenbau und Mechatronik (866)
- Fachbereich Chemie und Biotechnologie (847)
- Fachbereich Luft- und Raumfahrttechnik (776)
- Fachbereich Bauingenieurwesen (705)
- IfB - Institut für Bioengineering (686)
- INB - Institut für Nano- und Biotechnologien (613)
- Fachbereich Gestaltung (484)
- Solar-Institut Jülich (339)
- Fachbereich Architektur (174)
- FH Aachen (153)
- ECSM European Center for Sustainable Mobility (112)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (74)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (71)
- Nowum-Energy (70)
- Institut fuer Angewandte Polymerchemie (32)
- Sonstiges (24)
Thermodynamic stability, configurational motions and internal forces of haemoglobin (Hb) of three endotherms (platypus, Ornithorhynchus anatinus; domestic chicken, Gallus gallus domesticus and human, Homo sapiens) and an ectotherm (salt water crocodile, Crocodylus porosus) were investigated using circular dichroism, incoherent elastic neutron scattering and coarse-grained Brownian dynamics simulations. The experimental results from Hb solutions revealed a direct correlation between protein resilience, melting temperature and average body temperature of the different species on the 0.1 ns time scale. Molecular forces appeared to be adapted to permit conformational fluctuations with a root mean square displacement close to 1.2 Å at the corresponding average body temperature of the endotherms. Strong forces within crocodile Hb maintain the amplitudes of motion within a narrow limit over the entire temperature range in which the animal lives. In fully hydrated powder samples of human and chicken, Hb mean square displacements and effective force constants on the 1 ns time scale showed no differences over the whole temperature range from 10 to 300 K, in contrast to the solution case. A complementary result of the study, therefore, is that one hydration layer is not sufficient to activate all conformational fluctuations of Hb in the pico- to nanosecond time scale which might be relevant for biological function. Coarse-grained Brownian dynamics simulations permitted to explore residue-specific effects. They indicated that temperature sensing of human and chicken Hb occurs mainly at residues lining internal cavities in the β-subunits.
Thermal management in E-carsharing vehicles - preconditioning concepts of passenger compartments
(2015)
The issue of thermal management in electric vehicles includes the topics of drivetrain cooling and heating, interior temperature, vehicle body conditioning and safety. In addition to the need to ensure optimal thermal operating conditions of the drivetrain components (drive motor, battery and electrical components), thermal comfort must be provided for the passengers. Thermal comfort is defined as the feeling which expresses the satisfaction of the passengers with the ambient conditions in the compartment. The influencing factors on thermal comfort are the temperature and humidity as well as the speed of the indoor air and the clothing and the activity of the passengers, in addition to the thermal radiation and the temperatures of the interior surfaces. The generation and the maintenance of free visibility (ice- and moisture-free windows) count just as important as on-demand heating and cooling of the entire vehicle. A Carsharing climate concept of the innovative ec2go vehicle stipulates and allows for only seating areas used by passengers to be thermally conditioned in a close-to-body manner. To enable this, a particular feature has been added to the preconditioning of the Carsharing electric vehicle during the electric charging phase at the parking station.
Thermal synthesis of the optical pure pentapeptide derivative Z-(L)-Ala-(L)-Phe-Gly-(L)-Phe-Gly-OMe
(1980)
Im Rahmen des Exzellenzclusters „Integrative Produktionstechnik für Hochlohnländer“ der RWTHAachen University werden derzeit alternative Verfahren zur Herstellung von Metall/Kunststoff- Verbindungen untersucht. Eines davon ist das thermische Direktfügen, das eine stoffschlüssige Verbindung zwischen Kunststoff und Metall ermöglicht und ohne die Verwendung von Klebstoffen, Haftvermittlern oder mechanischen Verbindungshilfen auskommt.
In this article, we present an overview on the thermocatalytic reaction of hydrogen peroxide (H₂O₂) gas on a manganese (IV) oxide (MnO₂) catalytic structure. The principle of operation and manufacturing techniques are introduced for a calorimetric H₂O₂ gas sensor based on porous MnO₂. Results from surface analyses by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) of the catalytic material provide indication of the H₂O₂ dissociation reaction schemes. The correlation between theory and the experiments is documented in numerical models of the catalytic reaction. The aim of the numerical models is to provide further information on the reaction kinetics and performance enhancement of the porous MnO₂ catalyst.
Thermodynamic relations between component activities and gas solubilities in binary metallic systems
(1985)
This study focuses on thermoelectric elements (TEE) as an alternative for room temperature control. TEE are semi-conductor devices that can provide heating and cooling via a heat pump effect without direct noise emissions and no refrigerant use. An efficiency evaluation of the optimal operating mode is carried out for different numbers of TEE, ambient temperatures, and heating loads. The influence of an additional heat recovery unit on system efficiency and an unevenly distributed heating demand are examined. The results show that TEE can provide heat at a coefficient of performance (COP) greater than one especially for small heating demands and high ambient temperatures. The efficiency increases with the number of elements in the system and is subject to economies of scale. The best COP exceeds six at optimal operating conditions. An additional heat recovery unit proves beneficial for low ambient temperatures and systems with few TEE. It makes COPs above one possible at ambient temperatures below 0 ∘C. The effect increases efficiency by maximal 0.81 (from 1.90 to 2.71) at ambient temperature 5 K below room temperature and heating demand Q˙h=100W but is subject to diseconomies of scale. Thermoelectric technology is a valuable option for electricity-based heat supply and can provide cooling and ventilation functions. A careful system design as well as an additional heat recovery unit significantly benefits the performance. This makes TEE superior to direct current heating systems and competitive to heat pumps for small scale applications with focus on avoiding noise and harmful refrigerants.
Thermohydrodynamic analysis of thrust-bearing with circular pads running on bubbly oil (BTHD-theory)
(1985)
This study addresses a proof-of-concept experiment with a biocompatible screen-printed carbon electrode deposited onto a biocompatible and biodegradable substrate, which is made of fibroin, a protein derived from silk of the Bombyx mori silkworm. To demonstrate the sensor performance, the carbon electrode is functionalized as a glucose biosensor with the enzyme glucose oxidase and encapsulated with a silicone rubber to ensure biocompatibility of the contact wires. The carbon electrode is fabricated by means of thick-film technology including a curing step to solidify the carbon paste. The influence of the curing temperature and curing time on the electrode morphology is analyzed via scanning electron microscopy. The electrochemical characterization of the glucose biosensor is performed by amperometric/voltammetric measurements of different glucose concentrations in phosphate buffer. Herein, systematic studies at applied potentials from 500 to 1200 mV to the carbon working electrode (vs the Ag/AgCl reference electrode) allow to determine the optimal working potential. Additionally, the influence of the curing parameters on the glucose sensitivity is examined over a time period of up to 361 days. The sensor shows a negligible cross-sensitivity toward ascorbic acid, noradrenaline, and adrenaline. The developed biocompatible biosensor is highly promising for future in vivo and epidermal applications.
Thickness dependence of the electronic structure of ultrathin, epitaxial Ni(111)/W(110) layers.
(1988)
Thin film chemical sensors based on chalcogenide glasses for „electronic tongue“ applications
(2001)
For typical cases of non-isolated lightning
protection systems (LPS) the impulse currents are investigated which may flow through a human body directly touching a structural part of the LPS. Based on a basic LPS model with conventional down-conductors especially the cases of external and internal steel columns and metal façades are considered and compared. Numerical simulations of the line quantities voltages and currents in the time domain are performed with an equivalent circuit of the entire LPS.
As a result it can be stated that by increasing the number of conventional down-conductors and external steel columns the threat for a human being can indeed be reduced, but not down to an acceptable limit. In case of internal steel columns used as natural down-conductors the threat can be reduced sufficiently, depending on the low-resistive connection of the steel columns to the lightning equipotential bonding or the earth termination system, resp. If a metal façade is used the threat for human beings touching is usually very low, if the façade is sufficiently interconnected and multiply connected to the lightning equipotential bonding or the earth termination system, resp.