Refine
Year of publication
Institute
- IfB - Institut für Bioengineering (630) (remove)
Has Fulltext
- no (630) (remove)
Document Type
- Article (423)
- Conference Proceeding (117)
- Part of a Book (38)
- Doctoral Thesis (20)
- Report (10)
- Book (8)
- Conference: Meeting Abstract (5)
- Other (3)
- Habilitation (2)
- Patent (2)
Keywords
- solar sail (5)
- CellDrum (3)
- GOSSAMER-1 (3)
- MASCOT (3)
- Biocomposites (2)
- Biosolubilization (2)
- Coal (2)
- Iterative learning control (2)
- Limit analysis (2)
- Mars (2)
Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs
(2012)
The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines.
The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge.
All cells generate contractile tension. This strain is crucial for mechanically controlling the cell shape, function and survival. In this study, the CellDrum technology quantifying cell's (the cellular) mechanical tension on a pico-scale was used to investigate the effect of lipopolysaccharide (LPS) on human aortic endothelial cell (HAoEC) tension. The LPS effect during gram-negative sepsis on endothelial cells is cell contraction causing endothelium permeability increase. The aim was to finding out whether recombinant activated protein C (rhAPC) would reverse the endothelial cell response in an in-vitro sepsis model. In this study, the established in-vitro sepsis model was confirmed by interleukin 6 (IL-6) levels at the proteomic and genomic levels by ELISA, real time-PCR and reactive oxygen species (ROS) activation by florescence staining. The thrombin cellular contraction effect on endothelial cells was used as a positive control when the CellDrum technology was applied. Additionally, the Ras homolog gene family, member A (RhoA) mRNA expression level was checked by real time-PCR to support contractile tension results. According to contractile tension results, the mechanical predominance of actin stress fibers was a reason of the increased endothelial contractile tension leading to enhanced endothelium contractility and thus permeability enhancement. The originality of this data supports firstly the basic measurement principles of the CellDrum technology and secondly that rhAPC has a beneficial effect on sepsis influenced cellular tension. The technology presented here is promising for future high-throughput cellular tension analysis that will help identify pathological contractile tension responses of cells and prove further cell in-vitro models.
Suburethral slings as well as different meshes are widely used treating stress urinary incontinence and prolaps in women. With the development of MiniSlings and special meshes using less alloplastic material anchorage systems become more important to keep devices in place and to put some tension especially on the MiniSlings. To date, there are many different systems of MiniSlings of different companies on the market which differ in the structure of the used meshes and anchors. A new objective measurement method to compare different properties of MiniSling systems (mesh and anchor) is presented in this article. Ballistic gelatine acts as soft tissue surrogate. Significant differences in parameters like pull-out strength of anchors or shrinkage of meshes under loading conditions have been determined. The form and size of the anchors as well as the structural stability of the meshes are decisive for a proper integration. The tested anchorings sytems showed markedly different mechanical function at their respective load bearing capacity. As the stable fixation of the device in tissue is a prerequisite for a permanet reinforcement, the proposed test system permits further optimisation of anchor and mesh devices to improve the success of the surgical treatment
Autonomous robotic systems for penetrating thick ice shells with simultaneous collecting of scientific data are very promising devices in both terrestrial (glacier, climate research) and extra-terrestrial applications. Technical challenges in development of such systems are numerous and include 3D-navigation, an appropriate energy source, motion control, etc. Not less important is the problem of forward contamination of the pristine glacial environments with microorganisms and biomolecules from the surface of the probe. This study was devoted to establishing a laboratory model for microbial contamination of a newly constructed ice-melting probe called IceMole and to analyse the viability and amount of the contaminating microorganisms as a function of distance. The used bacterial strains were Bacillus subtilis (ATCC 6051) and Escherichia coli (ATCC 11775). The main objective was development of an efficient and reliable in-situ decontamination method of the melting probe. Therefore, several chemical substances were tested in respect of their efficacy to eliminate bacteria on the surface of the melting probe at low temperature (0 - 5 °C) and at continuous dilution by melted water. Our study has shown that at least 99.9% decontamination of the IceMole can be successfully achieved by the injection of 30% (v/v) hydrogen peroxide and 3% (v/v) sodium hypochlorite into the drilling site. We were able to reproduce this result in both time-dependent and depth-dependent experiments. The sufficient amount of 30% (v/v) H₂O₂ or 3% (v/v) NaClO has been found to be approximately 18 L per cm² of the probe’s surface.
Aims: Thrombotic complications due to activation of platelets and plasmatic clotting factors belong still to the most investigated topics in the field of study of patho-physiological mechanisms. Mathematical modeling of thrombotic reactions is established and validated in test cases. Aim of this study is to experimentally evaluate and computationally simulate platelets under the influence of well-defined shear flow conditions. Platelet behaviour and reactions are experimentally reproduced, measured and used for validation of the numerical simulation. Methods: A mathematical model of platelet activation, adhesion and aggregation has been implemented into a finite element CFD (Computational Fluid Dynamics) code. The approach is based on the advective and diffusive transport equations for resting platelets, activated platelets and platelet released agonists. Adhesion rates for the reactive surfaces depend on the hemocompatibility properties of the surface and the local shear rate. Experiments with citrate-anticoagulated freshly-drawn whole blood are performed in a perfusion flow chamber as well as in a system of rotating cylinders for Couette and Taylor-vortex flow. Different biomaterials are used. The activation, drop of platelet concentration, adhesion and aggregation are quantified using scanning electron microscopy (SEM) and flow cytometry. Results: Regions and flow conditions with a high potential for thrombus growth could be identified. The experiments clearly show the influence of the blood contacting material and flow properties. By means of SEM diverse platelet adhesion patterns are observed. Numerical analysis can explain the patterns and the degree of thrombus formation. Conclusion: The numerical method shows good agreement with experimental data indicating a possible prediction of initiation of activation and detection of the local adhesion areas in connection with the role of Von-Willebrand-Factor.
Purpose of Study: Thrombosis-related complications are among the leading causes for morbidity and mortality in patients who depend on artificial organs. For the prediction of platelet behavior both the flow conditions inside the device and the thrombogenic properties of the blood-contacting surfaces must be considered. Platelet reactions under the influence of well-defined shear rates are experimentally evaluated and numerically simulated. The approach is intended for the analysis of VAD and oxygenator design.
Methods Used: A mathematical model of platelet activation, adhesion and aggregation has been implemented into a finite element CFD (Computational Fluid Dynamics) code. The approach is based on the advective and diffusive transport equations for resting and activated platelets and platelet released agonists. Experiments with citrate-anticoagulated freshly-drawn whole blood are performed in a perfusion flow chamber as well as in a system of rotating cylinders for Couette and Taylor-vortex flow. Different biomaterials are used. The activation, adhesion and aggregation are quantified using scanning electron microscopy and flow cytometry.
Summary of Results: Regions and flow conditions with a high potential for thrombus growth could be identified. The experiments clearly show the influence of the blood contacting material and governing shear rates. Numerical analysis can explain observed adhesion patterns and the degree of thrombus formation
In this paper, we will provide a feasible mission design for a multiple-rendezvous mission to Jupiter's Trojans. It is based on solar electric propulsion, as being currently used on the DAWN spacecraft, and other flight-proven technology. First, we have selected a set of mission objectives, the prime objective being the detection of water -especially subsurface water -to provide evidence for the Trojans' formation at large solar distances. Based on DAWN and other comparable missions, we have determined suitable payload instruments to achieve these objectives. Afterwards, we have designed a spacecraft that is able to carry the selected payload to the Trojan region and rendezvous successively with three target bodies within a maximum mission duration of 15 years. Accurate low-thrust trajectories have been obtained with a global low-thrust trajectory optimization program (InTrance). During the transfer from Earth to the first target, the spacecraft is propelled by two RIT-22 ion engines from EADS Astrium, whereas a single RIT-15 is used for transfers within the Trojan region to reduce the required power. For power generation, the spacecraft uses a multi-junction solar array that is supported by concentrators. To achieve moderate mission costs, we have restricted the launch mass to a maximum of 1600 kg, the maximum interplanetary injection capability of a Soyuz/Fregat launcher. Our final layout has a mass of 1400 kg, yielding a margin of about 14%. Nestor (a member of the L4-population) was determined as the first mission target. It can be reached within 4.6 years from launch. The fuel mass ratio for this transfer is about 35%. The stay time at Nestor is 1.2 years. Eurymedon was selected as the second target (transfer time 3.5 years, stay time 3.0 years) and Irus as the third target (transfer time 2.2 years). The transfers within the Trojan L4-population can be accomplished with fuel mass ratios of about 3% for each trajectory leg. Including the stay times in orbit around the targets, the mission can be accomplished within a total duration of about 14.5 years. According to our mission analysis, it is also feasible to fly to the L5-population with similar flight times. It has to be noted that -for a first analysis -we have taken only the named targets into account. Allowing also rendezvous with unnamed objects will very likely decrease the mission duration. Based on a scaling of DAWN's mission costs (due to comparable scientific instruments and mission objectives), and taking into account the longer mission duration and the potential re-use of already developed technology, we have estimated that these three rendezvous can be accomplished with a budget of about 250 Million Euros, i.e. about 25% of ROSETTA's budget.
Visual Virology
(2012)
Upper and lower bound theorems of limit analyses have been presented in part I of the paper. Part II starts with the finite element discretization of these theorems and demonstrates how both can be combined in a primal–dual optimization problem. This recently proposed numerical method is used to guide the development of a new class of closed-form limit loads for circumferential defects, which show that only large defects contribute to plastic collapse with a rapid loss of strength with increasing crack sizes. The formulae are compared with primal–dual FEM limit analyses and with burst tests. Even closer predictions are obtained with iterative limit load solutions for the von Mises yield function and for the Tresca yield function. Pressure loading of the faces of interior cracks in thick pipes reduces the collapse load of circumferential defects more than for axial flaws. Axial defects have been treated in part I of the paper.
Solar sailcraft of the first generation technology development / Seboldt, Wolfgang ; Dachwald, Bernd
(2003)
The mission of the COMPASS-1 picosatellite is to take pictures of the earth, to validate a space-borne GPS receiver developed by the German Aerospace Center, and to verify the proper operation of the magnetic attitude control system in orbit. The spacecraft was launched on April 28, 2008 from the Indian space port Sriharikota, as part of the PSLV-C9 world record launch that simultaneously brought ten satellites into orbit. The mission operations were carried out from the ground stations in Aachen and Tainan. Arising difficulties in the communication link were overcome with the support of individuals from the amateur radio community. After several months of mission operation, abundant housekeeping and mission data has been commanded, received and analyzed and is presented in this paper.
Biomechanics studies biological soft tissue materials (growth, remodeling) in vivo. For this objective, the detailed information of material properties must be well defined to construct reliable constitutive models. In the paper, the bulge test is carried out with elastomers in order to develop a test method. Then, application of the test for soft tissue materials is straightforward due to the similarities between elastomers with soft tissue materials as proved in Holzapfel 2005, Ogden 2009. It means, after the preliminary experiments and parameter identification with rubber materials has been setup, experiments on soft tissue materials can be similarly carried out. Elastomers have a complex behavior which strongly depends on the largest previous load cycle. For simplicity we consider only the first loading.
Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method
(2010)
Background: To elaborate the impact of new haemostatic agents we developed an instrument for the pressure-controlled induction of blunt liver injuries in a porcine animal model. Materials and Methods: A dilutional coagulopathy of 80% of animal blood volume was induced in 9 anaesthetized pigs. Animals were randomly assigned to be injured with a force of 112 Newton (N) (n = 1), 224 ± 19 N (n = 4) or 355 ± 35 N (n = 4). The impact of injury was measured by blood loss, survival time and coagulation parameters. Liver histology was obtained to evaluate the degree of liver injury. Results: The profound haemodilution resulted in a significant alteration of all coagulation parameters. After inflicting the injury with 355 ± 35 N, both the survival time (30 ± 9 min; p = 0.006) and blood loss (68 ± 16 ml min–1, p = 0.002) were significantly different as compared to injuries with 224 ± 19 N (survival time: 76 ± 20 min, blood loss: 23 ± 4 ml min–1). In contrast, an injury with 112 N led to an insignificant blood loss of only 239 ml. Conclusion: We developed a pressure-controlled clamp that allows for the induction of blunt liver traumas with highly reproducible injuries with a positive correlation with blood loss and survival.