Refine
Year of publication
- 2009 (73) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (73) (remove)
Language
- English (73) (remove)
Document Type
- Article (65)
- Conference Proceeding (7)
- Book (1)
Keywords
- Stickstoffmonoxid (2)
- nitric oxide gas (2)
- Adsorption (1)
- Autofluoreszenzverfahren (1)
- Biophoton (1)
- Biosensor (1)
- Blitzschutz (1)
- Eisschicht (1)
- Elektrodynamik (1)
- Hydrodynamik (1)
- Hydrogel (1)
- Hämoglobin (1)
- Kohlenstofffaser (1)
- Lichtstreuungsbasierte Instrumente (1)
- Lipopolysaccharide (1)
- MEMS (1)
- Nanopartikel (1)
- Nanotechnology ; Microelectronics ; Biosensors ; Superconductor ; MEMS (1)
- Proteine (1)
- Sonde (1)
- Supraleiter (1)
- Wasserbrücke (1)
- activated nanostructured carbon (1)
- aktivierte nanostrukturierte Kohlenstofffaser (1)
- autofluorescence-based detection system (1)
- hemoglobin (1)
- hydrogel (1)
- light scattering analysis (1)
- lightning flash (1)
- lipopolysaccharides (1)
- protein (1)
- water bridge phenomenon (1)
Self-Adjoint Operator
(2009)
The monolithic scintillator block approach for gamma detection in the Positron Emission Tomography (PET) avoids estimating Depth of Interaction (DOI), reduces dead zones in detector and diminishes costs of detector production. Neural Networks (NN) are very efficient to determine the entrance point of a gamma incident on a scintillator block. This paper presents results on the robustness of the spatial resolution as a function of the random fraction in the data, temperature and HV fluctuations. This is important when implementing the method in a real scanner. Measurements were done with two Hamamatsu S8550 APD arrays, glued on a 20 Ã 20 Ã 10 mm3 monolithic LSO crystal block.
Projection
(2009)
In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not.
Operator
(2009)
The absence of a general method for endotoxin removal from liquid interfaces gives an opportunity to find new methods and materials to overcome this gap. Activated nanostructured carbon is a promising material that showed good adsorption properties due to its vast pore network and high surface area. The aim of this study is to find the adsorption rates for a carboneous material produced at different temperatures, as well as to reveal possible differences between the performance of the material for each of the adsorbates used during the study (hemoglobin, serum albumin and lipopolysaccharide, LPS).
Microfabrication, characterization and analytical application of a new thin-film silver microsensor
(2009)
Magnetotomography and Electric Currents in a Fuel Cell / Lustfeld, H. ; Reißel, M. ; Steffen, B.
(2009)
Layer-by-Layer Assembly of Carbon Nanotubes Incorporated in Light-Addressable Potentiometric Sensors
(2009)
As a deduction from these results, we can conclude that proteins mainly in vitro, denaturate totally at a temperature between 57°C -62°C, and they also affected by NO and different ions types. In which mainly, NO cause earlier protein denaturation, which means that, NO has a destabilizing effect on proteins, and also different ions will alter the protein denaturation in which, some ions will cause earlier protein denaturation while others not.