Refine
Year of publication
- 2012 (314) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (70)
- Fachbereich Wirtschaftswissenschaften (42)
- Fachbereich Chemie und Biotechnologie (39)
- Fachbereich Elektrotechnik und Informationstechnik (38)
- Fachbereich Bauingenieurwesen (30)
- INB - Institut für Nano- und Biotechnologien (30)
- IfB - Institut für Bioengineering (29)
- Fachbereich Maschinenbau und Mechatronik (27)
- Fachbereich Energietechnik (20)
- Solar-Institut Jülich (15)
Has Fulltext
- no (314) (remove)
Document Type
- Article (129)
- Conference Proceeding (81)
- Part of a Book (36)
- Book (26)
- Conference: Meeting Abstract (17)
- Patent (12)
- Doctoral Thesis (7)
- Report (3)
- Habilitation (1)
- Other (1)
Keywords
- (Bio)degradation (1)
- 3. EU Legislativpaket (1)
- 802.15.4 (1)
- Acceleration (1)
- Adsorption (1)
- Afterload (1)
- Alginate beads (1)
- Anastomotic leakage (1)
- Autolysis (1)
- Avalanche (1)
This article describes the functionality of a MATLAB® library that can be used to develop motion-logic applications in MATLAB programming language for industrial drive and control systems using the well known sercos automation bus. Therewith MATLAB's functionality is extended to designing automation applications from single axis machines up to multi-kinematic robots.
Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry
(2012)
A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes.
The radio-based wireless data communication has made the realization of new technical solutions possible in many fields of the automation technology (AT). For about ten years, a constant disproportionate growth of wireless technologies can be observed in the automation technology.
However, it shows that especially for the AT, conventional technologies of office automation are unsuitable and/or not manageable. The employment of mobile services in the industrial automation technology has the potential of significant cost and time savings. This leads to an increased productivity in various fields of the AT, for example in the factory and process automation or in production logistics. In this paper technologies and solutions for an automation-suited supply of mobile wireless services will be introduced under the criteria of real time suitability, IT-security and service orientation.
Emphasis will be put on the investigation and development of wireless convergence layers for different radio technologies, on the central provision of support services for an easy-to-use, central, backup enabled management of combined wired / wireless networks and on the study on integrability in a Profinet real-time Ethernet network.
Prioritization is an essential task within requirements engineering to cope with complexity and to establish focus properly. The 3rd Workshop on Requirements Prioritization for customer oriented Software Development (RePriCo’12) focused on requirements prioritization and adjacent themes in the context of customer oriented development of bespoke and standard software. Five submissions have been accepted for the proceedings and for presentation. The report summarizes and points out key findings.
All cells generate contractile tension. This strain is crucial for mechanically controlling the cell shape, function and survival. In this study, the CellDrum technology quantifying cell's (the cellular) mechanical tension on a pico-scale was used to investigate the effect of lipopolysaccharide (LPS) on human aortic endothelial cell (HAoEC) tension. The LPS effect during gram-negative sepsis on endothelial cells is cell contraction causing endothelium permeability increase. The aim was to finding out whether recombinant activated protein C (rhAPC) would reverse the endothelial cell response in an in-vitro sepsis model. In this study, the established in-vitro sepsis model was confirmed by interleukin 6 (IL-6) levels at the proteomic and genomic levels by ELISA, real time-PCR and reactive oxygen species (ROS) activation by florescence staining. The thrombin cellular contraction effect on endothelial cells was used as a positive control when the CellDrum technology was applied. Additionally, the Ras homolog gene family, member A (RhoA) mRNA expression level was checked by real time-PCR to support contractile tension results. According to contractile tension results, the mechanical predominance of actin stress fibers was a reason of the increased endothelial contractile tension leading to enhanced endothelium contractility and thus permeability enhancement. The originality of this data supports firstly the basic measurement principles of the CellDrum technology and secondly that rhAPC has a beneficial effect on sepsis influenced cellular tension. The technology presented here is promising for future high-throughput cellular tension analysis that will help identify pathological contractile tension responses of cells and prove further cell in-vitro models.
Risiken des Handels
(2012)
As part of a novel approach to automatic sewer inspection, this paper presents a robust algorithm for automatic flow line detection. A large image repository is obtained from about 50,000 m sewers to represent the high variability of real world sewer systems. Automatic image processing combines Canny edge detection, Hough transform for straight lines and cost minimization using Dijkstra's shortest path algorithm. Assuming that flow lines are mostly smoothly connected horizontal structures, piecewise flow line delineation is reduced to a process of selecting adjacent line candidates. Costs are derived from the gap between adjacent candidates and their reliability. A single parameter α enables simple control of the algorithm. The detected flow line may precisely follow the segmented edges (α = 0.0) or minimize gaps at joints (α = 1.0). Both, manual and ground truth-based analysis indicate that α = 0.8 is optimal and independent of the sewer's material. The algorithm forms an essential step to further automation of sewer inspection.
Selective laser melting of metals: desktop machines open up new chances even for small companies
(2012)
Additive manufacturing (AM) of metal parts by using Selective Laser Melting (SLM) has become a powerful tool mostly in the area of automotive, aerospace engineering and others. Especially in the field of dentistry, jewelry and related branches that require individualized or even one-of-a-kind products, the direct digital manufacturing process opens up new ways of design and manufacturing. In these fields, mostly small and medium sized businesses (SME) are operating which do not have sufficient human and economic resources to invest in this technology. But to stay competitive, the application of AM can be regarded as a necessity. In this situation a new desktop machine (Realizer SLM 50) was introduced that cost about 1/3 of a shop floor SLM machine and promises small quality parts. To find out whether the machine really is an alternative for SMEs the University of Applied Science, Aachen, Germany, designed, build and optimized typical parts from the dentistry and the jewelry branches using CoCr and silver material, the latter being new with this application. The paper describes the SLM procedure and how to find and optimize the most important parameters. The test is accompanied by digital simulation in order to verify the build parameters and to plan future builds. The procedure is shown as well as the resulting parts made from CoCr and silver material.
Sensitivity of phase detection techniques in aerated chute flows to hydraulic design parameters
(2012)
Siedlungswasserwirtschaft
(2012)
Siedlungswasserwirtschaft
(2012)
The Volatility Framework is a collection of tools for the analysis of computer RAM. The framework offers a multitude of analysis options and is used by many investigators worldwide. Volatility currently comes with a command line interface only, which might be a hinderer for some investigators to use the tool. In this paper we present a GUI and extensions for the Volatility Framework, which on the one hand simplify the usage of the tool and on the other hand offer additional functionality like storage of results in a database, shortcuts for long Volatility Framework command sequences, and entirely new commands based on correlation of data stored in the database.
The interest in PET detectors with monolithic block scintillators is growing. In order to obtain high spatial resolutions dedicated positioning algorithms are required. But even an ideal algorithm can only deliver information which is provided by the detector. In this simulation study we investigated the light distribution on one surface of cuboid LSO scintillators of different size. Scintillators with a large aspect ratio (small footprint and large height) showed significant position information only for a minimum interaction depth of the gamma particle. The results allow a quantitative estimate for a useful aspect ratio.
Smartphone Forensik
(2012)
Stahlbau
(2012)
Stahlbau
(2012)
Die bauaufsichtliche Einführung der Eurocodes steht unmittelbar bevor. Für den Bereich des Stahl- und Spannbetonbaus soll die Anwendung zum 1. Juli 2012 verbindlich sein, d. h. mit diesem Stichtag sollte nur noch der Eurocode 2 (DIN EN 1992-1-1, Ausgabe Januar 2011) mit seinem zugehörigen nationalen Anhang (DIN EN 1992-1-1/NA, Ausgabe Januar 2011) Verwendung finden, die DIN 1045-1 wird zurückgezogen. Bereits seit März 2010 gilt eine Übergangsphase, ist der die Anwendung des Eurocodes alternativ zur DIN 1045-1 als bauaufsichtlich gleichwertige Lösung möglich.
Stahlbetonbau
(2012)
In this research work, a statistical analysis of the CO2 laser beam welding of dual phase (DP600)/transformation induced plasticity (TRIP700) steel sheets was done using response surface methodology. The analysis considered the effect of laser power (2–2.2 kW), welding speed (40–50 mm/s) and focus position (−1 to 0 mm) on the heat input, the weld bead geometry, uniaxial tensile strength, formability limited dome height and welding operation cost. The experimental design was based on Box–Behnken design using linear and quadratic polynomial equations for predicting the mathematical models. The results indicate that the proposed models predict the responses adequately within the limits of welding parameters being used and the welding speed is the most significant parameter during the welding process.
The construction of a statistical test is investigated which is based only on “reliability” and “precision” as quality criteria. The reliability of a statistical test is quantifiedin a straightforward way by the probability that the decision of the test is correct. However, the quantification of the precision of a statistical test is not at all evident. Thereforethe paper presents and discusses several approaches. Moreover the distinction of “nullhypothesis” and “alternative hypothesis” is not necessary any longer.
Die Hochgradientenmagnetseparation (HGMS) ist eine Methode zur Aufreinigung von biopharmazeutischen Produkten. Mit dieser Methode lässt sich in nur einem Schritt eine Fest/Fest/Flüssig-Trennung erzielen, was zu einer erheblichen Zeit- und Kostenersparnis im Downstreaming führt. Dennoch steht ihr industrieller Einsatz noch aus, was u. a. am Mangel an Analysenmethoden liegt, um die HGMS quantifizierbar zu machen. Gerade in der Pharmaproduktion werden Prozesse gebraucht, die gemäß den einschlägigen Vorschriften (cGMP) validiert und deren verfahrenstechnische Anlagenteile qualifiziert werden können. Die Schwierigkeit ist die Messung der magnetischen Mikrosorbentien in der Suspension, in der auch Zellen oder Zelltrümmer vorliegen. Im Rahmen eines Forschungsprojektes im „Zentralen Innovationsprogramm Mittelstand“ des BMWi wurden verschiedene Analysenmethoden untersucht. Die Durchflusszytometrie ermöglicht eine Charakterisierung von Partikeln und eine simultane quantitative Messung. Durch die multiparametrige Messung kann zwischen Zellen, Zelltrümmern und Magnetpartikeln unterschieden werden. Die At-line-Einbindung des Durchflusszytometers ist durch den Einsatz einer externen Pumpe möglich. Über eine automatisierte Messwertanalyse kann der HGMS-Prozess mittels der Durchflusszytometrie gesteuert werden.
Biodiversity and the coexistence of species have puzzled and fascinated biologists since decades and is a hotspot in todays’ natural sciences. Preserving this biodiversity is a great challenge as habitats and environments underlying tremendous changes like climate change and the loss of natural habitats, which are mainly due to anthropogenic influences. The coexistence of numerous species even in homogeneous environments is a stunning feature of natural communities and has been summarized under the term ‘paradox of plankton’. Up to now, there are several mechanisms discussed, which may contribute to local and global diversity of organisms. Several interspecific trade offs have been identified maintaining the coexistence of species like their abilities regarding competition and predator avoidance, their capability to disperse in space and time, and their ability to exploit variable resources. Further, micro-evolutionary dynamics supporting the coexistence of species have been added to our knowledge, and deriving from theoretical deterministic models, non-linear dynamics which describe the temporal fluctuation of abundances of organisms. Whereas competition and predation seem to be clue structural elements within interacting organisms, the intrinsic dynamic behavior – by means of temporal changes in abundance - plays an important role regarding coexistence within a community. The present work sheds light on different factors affecting the coexistence of species using experimental microbial model systems consisting of a bacterivorous ciliate as the predator and two bacteria strains as prey organism. Additionally, another experimental setup consisting of two up to five bacteria species competing for one limiting resource was investigated. Highly controllable chemostat systems were established to exclude extrinsic disturbances. According to theoretical analyses I was able to show - experimentally and theoretically - that phenotypic plasticity of one species within a microbial one-predator-two-prey food web enlarges the range of possible coexistence of all species under different dynamic conditions, compared to a food web without phenotypic plasticity. This was accompanied by non-linear (chaotic) population dynamics within all experimental systems showing phenotypic plasticity. The experiments on the interplay of competition, predation and invasion showed that all aspects have an influence on species coexistence. Under undisturbed controlled conditions all aspects were analyzed in detail and in combination. Populations showed oscillations which were shown by quasi-chaotic attractors in phase space diagrams. Competition experiments with two up to five bacteria species competing for one limiting resource showed that all organisms were able to coexist which was mediated by species oscillations entering a regime of chaos. Besides that fact it was found, that the productivity (biomass) as well as the total cell numbers – under the same nutrition supply – increased by an increasing number of species in the experimental systems. Up to now, the occurrence of non-linear dynamics in well controlled experimental studies has been recognized several times and this phenomenon seemed to be more common in natural systems than generally assumed.