Article
Refine
Year of publication
- 2024 (50)
- 2023 (80)
- 2022 (93)
- 2021 (109)
- 2020 (135)
- 2019 (123)
- 2018 (127)
- 2017 (109)
- 2016 (118)
- 2015 (126)
- 2014 (142)
- 2013 (139)
- 2012 (130)
- 2011 (182)
- 2010 (141)
- 2009 (199)
- 2008 (180)
- 2007 (176)
- 2006 (179)
- 2005 (188)
- 2004 (214)
- 2003 (154)
- 2002 (167)
- 2001 (157)
- 2000 (173)
- 1999 (153)
- 1998 (165)
- 1997 (154)
- 1996 (140)
- 1995 (147)
- 1994 (136)
- 1993 (108)
- 1992 (102)
- 1991 (74)
- 1990 (82)
- 1989 (79)
- 1988 (80)
- 1987 (77)
- 1986 (65)
- 1985 (59)
- 1984 (56)
- 1983 (47)
- 1982 (38)
- 1981 (39)
- 1980 (50)
- 1979 (43)
- 1978 (41)
- 1977 (22)
- 1976 (25)
- 1975 (18)
- 1974 (13)
- 1973 (6)
- 1972 (15)
- 1971 (7)
- 1970 (2)
- 1968 (2)
- 1967 (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (1586)
- Fachbereich Wirtschaftswissenschaften (704)
- Fachbereich Elektrotechnik und Informationstechnik (629)
- Fachbereich Chemie und Biotechnologie (604)
- Fachbereich Energietechnik (604)
- INB - Institut für Nano- und Biotechnologien (538)
- Fachbereich Maschinenbau und Mechatronik (497)
- IfB - Institut für Bioengineering (445)
- Fachbereich Luft- und Raumfahrttechnik (375)
- Fachbereich Bauingenieurwesen (334)
Language
Document Type
- Article (5637) (remove)
Keywords
- Einspielen <Werkstoff> (7)
- Multimediamarkt (6)
- Rapid prototyping (5)
- avalanche (5)
- Earthquake (4)
- FEM (4)
- Finite-Elemente-Methode (4)
- LAPS (4)
- Rapid Prototyping (4)
- SLM (4)
Am Beispiel der Telekommunikationsindustrie zeigt der Beitrag eine konkrete Ausgestaltung anwendungsorientierter Forschung, die sowohl für die Praxis als auch für die Wissenschaft nutzen- und erkenntnisbringend ist. Forschungsgegenstand sind die Referenzmodelle des Industriegremiums TM Forum, die von vielen Telekommunikationsunternehmen zur Transformation ihrer Strukturen und Systeme genutzt werden. Es wird die langjährige Forschungstätigkeit bei der Weiterentwicklung und Anwendung dieser Referenzmodelle beschrieben. Dabei wird ein konsequent gestaltungsorientierter Forschungsansatz verfolgt. Das Zusammenspiel aus kontinuierlicher Weiterentwicklung in Zusammenarbeit mit einem Industriegremium und der Anwendung in vielfältigen Praxisprojekten führt zu einer erfolgreichen Symbiose aus praktischer Nutzengenerierung sowie wissenschaftlichem Erkenntnisgewinn. Der Beitrag stellt den gewählten Forschungsansatz anhand konkreter Beispiele vor. Darauf basierend werden Empfehlungen und Herausforderungen für eine gestaltungs- und praxisorientierte Forschung diskutiert.
The molecular weight properties of lignins are one of the key elements that need to be analyzed for a successful industrial application of these promising biopolymers. In this study, the use of 1H NMR as well as diffusion-ordered spectroscopy (DOSY NMR), combined with multivariate regression methods, was investigated for the determination of the molecular weight (Mw and Mn) and the polydispersity of organosolv lignins (n = 53, Miscanthus x giganteus, Paulownia tomentosa, and Silphium perfoliatum). The suitability of the models was demonstrated by cross validation (CV) as well as by an independent validation set of samples from different biomass origins (beech wood and wheat straw). CV errors of ca. 7–9 and 14–16% were achieved for all parameters with the models from the 1H NMR spectra and the DOSY NMR data, respectively. The prediction errors for the validation samples were in a similar range for the partial least squares model from the 1H NMR data and for a multiple linear regression using the DOSY NMR data. The results indicate the usefulness of NMR measurements combined with multivariate regression methods as a potential alternative to more time-consuming methods such as gel permeation chromatography.
In this study, a recently proposed NMR standardization approach by 2H integral of deuterated solvent for quantitative multicomponent analysis of complex mixtures is presented. As a proof of principle, the existing NMR routine for the analysis of Aloe vera products was modified. Instead of using absolute integrals of targeted compounds and internal standard (nicotinamide) from 1H-NMR spectra, quantification was performed based on the ratio of a particular 1H-NMR compound integral and 2H-NMR signal of deuterated solvent D2O. Validation characteristics (linearity, repeatability, accuracy) were evaluated and the results showed that the method has the same precision as internal standardization in case of multicomponent screening. Moreover, a dehydration process by freeze drying is not necessary for the new routine. Now, our NMR profiling of A. vera products needs only limited sample preparation and data processing. The new standardization methodology provides an appealing alternative for multicomponent NMR screening. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and is recommended in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).
The investigation of the possibility to determine various characteristics of powder heparin (n = 115) was carried out with infrared spectroscopy. The evaluation of heparin samples included several parameters such as purity grade, distributing company, animal source as well as heparin species (i.e. Na-heparin, Ca-heparin, and heparinoids). Multivariate analysis using principal component analysis (PCA), soft independent modelling of class analogy (SIMCA), and partial least squares – discriminant analysis (PLS-DA) were applied for the modelling of spectral data. Different pre-processing methods were applied to IR spectral data; multiplicative scatter correction (MSC) was chosen as the most relevant.
Obtained results were confirmed by nuclear magnetic resonance (NMR) spectroscopy. Good predictive ability of this approach demonstrates the potential of IR spectroscopy and chemometrics for screening of heparin quality. This approach, however, is designed as a screening tool and is not considered as a replacement for either of the methods required by USP and FDA.
Quantitative nuclear magnetic resonance (qNMR) is routinely performed by the internal or external standardization. The manuscript describes a simple alternative to these common workflows by using NMR signal of another active nuclei of calibration compound. For example, for any arbitrary compound quantification by NMR can be based on the use of an indirect concentration referencing that relies on a solvent having both 1H and 2H signals. To perform high-quality quantification, the deuteration level of the utilized deuterated solvent has to be estimated.
In this contribution the new method was applied to the determination of deuteration levels in different deuterated solvents (MeOD, ACN, CDCl3, acetone, benzene, DMSO-d6). Isopropanol-d6, which contains a defined number of deuterons and protons, was used for standardization. Validation characteristics (precision, accuracy, robustness) were calculated and the results showed that the method can be used in routine practice. Uncertainty budget was also evaluated. In general, this novel approach, using standardization by 2H integral, benefits from reduced sample preparation steps and uncertainties, and can be applied in different application areas (purity determination, forensics, pharmaceutical analysis, etc.).
Heparin is a natural polysaccharide, which plays essential role in many biological processes. Alterations in building blocks can modify biological roles of commercial heparin products, due to significant changes in the conformation of the polymer chain. The variability structure of heparin leads to difficulty in quality control using different analytical methods, including infrared (IR) spectroscopy. In this paper molecular modelling of heparin disaccharide subunits was performed using quantum chemistry. The structural and spectral parameters of these disaccharides have been calculated using RHF/6-311G. In addition, over-sulphated chondroitin sulphate disaccharide was studied as one of the most widespread contaminants of heparin. Calculated IR spectra were analyzed with respect to specific structure parameters. IR spectroscopic fingerprint was found to be sensitive to substitution pattern of disaccharide subunits. Vibrational assignments of calculated spectra were correlated with experimental IR spectral bands of native heparin. Chemometrics was used to perform multivariate analysis of simulated spectral data.
Lignin is a promising renewable biopolymer being investigated worldwide as an environmentally benign substitute of fossil-based aromatic compounds, e.g. for the use as an excipient with antioxidant and antimicrobial properties in drug delivery or even as active compound. For its successful implementation into process streams, a quick, easy, and reliable method is needed for its molecular weight determination. Here we present a method using 1H spectra of benchtop as well as conventional NMR systems in combination with multivariate data analysis, to determine lignin’s molecular weight (Mw and Mn) and polydispersity index (PDI). A set of 36 organosolv lignin samples (from Miscanthus x giganteus, Paulownia tomentosa and Silphium perfoliatum) was used for the calibration and cross validation, and 17 samples were used as external validation set. Validation errors between 5.6% and 12.9% were achieved for all parameters on all NMR devices (43, 60, 500 and 600 MHz). Surprisingly, no significant difference in the performance of the benchtop and high-field devices was found. This facilitates the application of this method for determining lignin’s molecular weight in an industrial environment because of the low maintenance expenditure, small footprint, ruggedness, and low cost of permanent magnet benchtop NMR systems.
NMR standardization approach that uses the 2H integral of deuterated solvent for quantitative multinuclear analysis of pharmaceuticals is described. As a proof of principle, the existing NMR procedure for the analysis of heparin products according to US Pharmacopeia monograph is extended to the determination of Na+ and Cl- content in this matrix. Quantification is performed based on the ratio of a 23Na (35Cl) NMR integral and 2H NMR signal of deuterated solvent, D2O, acquired using the specific spectrometer hardware. As an alternative, the possibility of 133Cs standardization using the addition of Cs2CO3 stock solution is shown. Validation characteristics (linearity, repeatability, sensitivity) are evaluated. A holistic NMR profiling of heparin products can now also be used for the quantitative determination of inorganic compounds in a single analytical run using a single sample. In general, the new standardization methodology provides an appealing alternative for the NMR screening of inorganic and organic components in pharmaceutical products.
Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize.
Das Gesundheitswesen ist konfrontiert mit steigenden Kosten und einer immer schwieriger werdenden Personalsituation. Zeitgleich versprechen moderne Sprachsteuerungssysteme Prozesse in Arztpraxen und Krankenhäusern zu verschlanken und Vorgänge zu beschleunigen. Dennoch wird derzeit der Einsatz von Sprachsteuerungssystemen in Arztpraxen oder Krankenhäusern nur selten beobachtet, was auch an den besonders strengen Datenschutzauflagen der Datenschutzgrundverordnung (DSGVO) liegt. Darüber hinaus wirft die niedrige Nutzungsrate die Frage nach den konkreten Anforderungen und ihrer Umsetzbarkeit auf, was durch den vorliegenden Beitrag adressiert wird, indem die Ergebnisse von Interviews mit acht medizinischen Fachexperten ausgewertet werden. Ergänzend wird die technische Umsetzbarkeit einzelner Anforderungen mit unterschiedlichen Cloud-Anbietern erprobt.