Refine
Year of publication
- 2005 (303) (remove)
Institute
- Fachbereich Medizintechnik und Technomathematik (48)
- Fachbereich Maschinenbau und Mechatronik (43)
- Fachbereich Luft- und Raumfahrttechnik (41)
- Fachbereich Energietechnik (39)
- Fachbereich Wirtschaftswissenschaften (29)
- Fachbereich Elektrotechnik und Informationstechnik (25)
- IfB - Institut für Bioengineering (24)
- Fachbereich Chemie und Biotechnologie (20)
- Fachbereich Bauingenieurwesen (18)
- INB - Institut für Nano- und Biotechnologien (17)
Language
- German (170)
- English (130)
- Portuguese (2)
- Spanish (1)
Document Type
- Article (188)
- Conference Proceeding (37)
- Book (30)
- Lecture (18)
- Part of a Book (12)
- Patent (6)
- Other (3)
- Part of a Periodical (3)
- Doctoral Thesis (2)
- Diploma Thesis (1)
Keywords
- Rapid Prototyping (6)
- Übungsklausur (5)
- Aachen University of Applied Sciences (3)
- Bauingenieurwesen (3)
- CAD (3)
- Fachhochschule Aachen (3)
- Fertigungsverfahren (3)
- Regelungstechnik (3)
- civil engineering (3)
- Karosseriebau (2)
The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it.
Die vorliegende Erfindung betrifft eine Vorrichtung zum Halten eines lebenden Objektes bei physiologischen Messungen mit einem Basiselement und Mitteln zum Arretieren des lebenden Objektes, die atraumatische Ohrenhalter sowie ein Mundstück aufweisen, das mit einer Aussparung für die Zähne des Lebewesens versehen ist, mit einem Masseanteil von wenigstens 95% an glasfaserverstärktem Kunststoff.