Article
Refine
Year of publication
- 2016 (116) (remove)
Document Type
- Article (116) (remove)
Keywords
- Additive Manufacturing (1)
- Annulus Fibrosus (1)
- Asymptotic efficiency (1)
- Bacillus atrophaeus (1)
- Balance (1)
- Balanced hypergraph (1)
- Brandfall (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- CellDrum (1)
- Censored data (1)
- Co-managed care (1)
- Computational biomechanics (1)
- DNA biosensor (1)
- Designpraxis (1)
- Disc Degeneration (1)
- Drug simulation (1)
- Duality (1)
- EN 1993-1-2 (1)
- Einbetten in das Internet der Dinge (1)
Institute
- Fachbereich Medizintechnik und Technomathematik (32)
- Fachbereich Chemie und Biotechnologie (19)
- IfB - Institut für Bioengineering (18)
- Fachbereich Wirtschaftswissenschaften (17)
- Fachbereich Elektrotechnik und Informationstechnik (14)
- INB - Institut für Nano- und Biotechnologien (12)
- Fachbereich Luft- und Raumfahrttechnik (11)
- Fachbereich Maschinenbau und Mechatronik (10)
- Fachbereich Bauingenieurwesen (8)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (6)
- Fachbereich Energietechnik (5)
- Institut fuer Angewandte Polymerchemie (5)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (2)
- ECSM European Center for Sustainable Mobility (1)
- Fachbereich Gestaltung (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
- Nowum-Energy (1)
The light-addressable potentiometric sensor (LAPS) has the unique feature to address different regions of a sensor surface without the need of complex structures. Measurements at different locations on the sensor surface can be performed in a common analyte solution, which distinctly simplifies the fluidic set-up. However, the measurement in a single analyte chamber prevents the application of different drugs or different concentrations of a drug to each measurement spot at the same time as in the case of multi-reservoir-based set-ups. In this work, the authors designed a LAPS-based set-up for cell culture screening that utilises magnetic beads loaded with the endotoxin (lipopolysaccharides, LPS), to generate a spatially distributed gradient of analyte concentration. Different external magnetic fields can be adjusted to move the magnetic beads loaded with a specific drug within the measurement cell. By recording the metabolic activities of a cell layer cultured on top of the LAPS surface, this work shows the possibility to apply different concentrations of a sample along the LAPS measurement spots within a common analyte solution.