Production of Co-58m in a siphon-style liquid target on a medical cyclotron
- We present the production of 58mCo on a small, 13 MeV medical cyclotron utilizing a siphon style liquid target system. Different concentrated iron(III)-nitrate solutions of natural isotopic distribution were irradiated at varying initial pressures and subsequently separated by solid phase extraction chromatography. The radio cobalt (58m/gCo and 56Co) was successfully produced with saturation activities of (0.35 ± 0.03) MBq μA−1 for 58mCo with a separation recovery of (75 ± 2) % of cobalt after one separation step utilizing LN-resin.
Verfasserangaben: | Lucas Mues genannt Koers, S. W. McNeil, V. Radchenko, Elisabeth PaulßenORCiD, Cornelia Hoehr |
---|---|
DOI: | https://doi.org/10.1016/j.apradiso.2023.110734 |
ISSN: | 0969-8043 |
Verlag: | Elsevier |
Verlagsort: | Amsterdam |
Dokumentart: | Wissenschaftlicher Artikel |
Sprache: | Englisch |
Erscheinungsjahr: | 2023 |
Datum der Erstveröffentlichung: | 26.02.2023 |
Datum der Publikation (Server): | 12.07.2024 |
Jahrgang: | 195 |
Ausgabe / Heft: | Art. 110734 |
Aufsatznummer: | 110734 |
Link: | https://doi.org/10.1016/j.apradiso.2021.110734 |
Zugriffsart: | campus |
Fachbereiche und Einrichtungen: | FH Aachen / Fachbereich Chemie und Biotechnologie |
collections: | Verlag / Elsevier |