Seismic verification of existing masonry buildings and strengthening with reinforced concrete jackets

  • A methodology for assessment, seismic verification and strengthening of existing masonry buildings is presented in this paper. The verification is performed using a calculation model calibrated with the results from ambient vibration measurements. The calibrated model serves as an input for a deformation-based verification procedure based on the Capacity Spectrum Method (CSM). The bearing capacity of the building is calculated from experimental capacity curves of the individual walls idealized with bilinear elastic-perfectly plastic curves. The experimental capacity curves were obtained from in-plane cyclic loading tests on unreinforced and strengthened masonry walls with reinforced concrete jackets. The seismic action is compared with the load-bearing capacity of the building considering non-linear material behavior with its post-peak capacity. The application of the CSM to masonry buildings and the influence of a traditional strengthening method are demonstrated on the example of a public school building in Skopje, Macedonia.

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Sergej Churilov, Elena Dumova-Jovanoska, Christoph ButenwegORCiD
ISBN:978-3-902749-04-8
Parent Title (English):Proceedings - Vienna Congress on Recent Advances in Earthquake Engineering and Structural Dynamics 2013 (VEESD 2013)
Editor:Christoph Adam, Rudolf Heuer, Wolfgang Lenhardt, Christian Schranz
Document Type:Conference Proceeding
Language:English
Year of Completion:2013
Date of the Publication (Server):2023/02/14
Note:
Vienna Congress on Recent Advances in Earthquake Engineering and Structural Dynamics, Vienna, Austria, Paper No. 523
13. D-A-CH Tagung ; Vienna, Austria, 29. - 30. August 2013
http://hdl.handle.net/20.500.12188/15830 (Error - Cannot Connect to Server)
Zugriffsart:bezahl
Institutes:FH Aachen / Fachbereich Energietechnik