Detection of hydrogen peroxide vapor by use of manganese(IV) oxide as catalyst for calorimetric gas sensors

  • In this work, the catalyst manganese(IV) oxide (MnO2), of calorimetric gas sensors (to monitor the sterilization agent vaporized hydrogen peroxide) has been investigated in more detail. Chemical analyses by means of X-ray-induced photoelectron spectroscopy have been performed to unravel the surface chemistry prior and after exposure to hydrogen peroxide vapor at elevated temperature, as applied in the sterilization processes of beverage cartons. The surface characterization reveals a change in oxidation states of the metal oxide catalyst after exposure to hydrogen peroxide. Additionally, a cleaning effect of the catalyst, which itself is attached to the sensor surface by means of a polymer interlayer, could be observed.

Metadaten exportieren

Weitere Dienste

Teilen auf X Suche bei Google Scholar
Metadaten
Verfasserangaben:Jan OberländerORCiD, Patrick Kirchner, Hans-Gerd Boyen, Michael Josef SchöningORCiD
DOI:https://doi.org/10.1002/pssa.201330359
ISSN:1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print)
Titel des übergeordneten Werkes (Englisch):Physica status solidi A: Applications and materials science
Verlag:Wiley-VCH
Verlagsort:Weinheim
Dokumentart:Wissenschaftlicher Artikel
Sprache:Englisch
Erscheinungsjahr:2014
Datum der Publikation (Server):25.03.2014
Jahrgang:211
Ausgabe / Heft:6
Erste Seite:1372
Letzte Seite:1376
Link:https://doi.org/10.1002/pssa.201330359
Zugriffsart:campus
Fachbereiche und Einrichtungen:FH Aachen / Fachbereich Medizintechnik und Technomathematik
FH Aachen / INB - Institut für Nano- und Biotechnologien
collections:Verlag / Wiley-VCH