Influence of prior in-plane damage on the out-of-plane response of non-load bearing unreinforced masonry walls under seismic load

  • Reinforced concrete frames with masonry infill walls are popular form of construction all over the world as well in seismic regions. While severe earthquakes can cause high level of damage of both reinforced concrete and masonry infills, earthquakes of lower to medium intensity some-times can cause significant level of damage of masonry infill walls. Especially important is the level of damage of face loaded infill masonry walls (out-of-plane direction) as out-of-plane load cannot only bring high level of damage to the wall, it can also be life-threating for the people near the wall. The response in out-of-plane direction directly depends on the prior in-plane damage, as previous investigation shown that it decreases resistance capacity of the in-fills. Behaviour of infill masonry walls with and without prior in-plane load is investigated in the experimental campaign and the results are presented in this paper. These results are later compared with analytical approaches for the out-of-plane resistance from the literature. Conclusions based on the experimental campaign on the influence of prior in-plane damage on the out-of-plane response of infill walls are compared with the conclusions from other authors who investigated the same problematic.

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Bogdan Šakić, Aleksa Milijaš, Marko Marinković, Christoph ButenwegORCiD, Sven Klinkel
DOI:https://doi.org/10.7712/120121.8527.18913
ISBN:9786188507258
ISSN:2623-3347
Parent Title (English):8th ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering
Publisher:National Technical University of Athens
Place of publication:Athen
Editor:Manolis Papadrakakis, Michalis Fragiadakis
Document Type:Conference Proceeding
Language:English
Year of Completion:2021
Date of the Publication (Server):2023/02/02
Tag:Earthquake Engineering; In- plane damage; Out-of-plane failure; Out-of-plane load; Unreinforced masonry walls
Length:21 Seiten
First Page:808
Last Page:828
Note:
COMPDYN 2021
28-30 June 2021, Streamed from Athens, Greece
Link: https://doi.org/10.7712/120121.8527.18913
Zugriffsart:weltweit
Institutes:FH Aachen / Fachbereich Energietechnik
collections:Verlag / National Technical University of Athens
Open Access / Bronze