Refine
Year of publication
Document Type
- Conference Proceeding (227)
- Bachelor Thesis (141)
- Article (122)
- Administrative publication (76)
- Part of Periodical (61)
- Lecture (30)
- Book (22)
- Report (19)
- Diploma Thesis (12)
- Course Material (9)
- Other (9)
- Study Thesis (5)
- Working Paper (5)
- Part of a Book (4)
- Master's Thesis (3)
- Talk (2)
- Poster (1)
Language
- German (522)
- English (218)
- Portuguese (6)
- Multiple languages (1)
- Spanish (1)
Has Fulltext
- yes (748) (remove)
Keywords
- Amtliche Mitteilung (71)
- Bachelor (33)
- Aachen University of Applied Sciences (31)
- Master (31)
- Prüfungsordnung (31)
- Bauingenieurwesen (30)
- Lesbare Fassung (28)
- Biosensor (25)
- Fachhochschule Aachen (23)
- Studien- und Prüfungsordnung (21)
- Aachen / Fachhochschule Aachen (20)
- Änderungsordnung (20)
- Blitzschutz (18)
- Elektromobilität (17)
- CAD (16)
- Finite-Elemente-Methode (16)
- civil engineering (14)
- Einspielen <Werkstoff> (13)
- Illustration (12)
- Elektrofahrzeug (11)
Institute
- Fachbereich Gestaltung (151)
- FH Aachen (150)
- Fachbereich Medizintechnik und Technomathematik (145)
- Fachbereich Maschinenbau und Mechatronik (67)
- IfB - Institut für Bioengineering (63)
- Fachbereich Energietechnik (48)
- Fachbereich Bauingenieurwesen (47)
- Fachbereich Wirtschaftswissenschaften (38)
- Fachbereich Elektrotechnik und Informationstechnik (34)
- INB - Institut für Nano- und Biotechnologien (29)
- Fachbereich Luft- und Raumfahrttechnik (27)
- Fachbereich Chemie und Biotechnologie (18)
- Fachbereich Architektur (13)
- ZHQ - Bereich Hochschuldidaktik und Evaluation (12)
- ECSM European Center for Sustainable Mobility (6)
- Nowum-Energy (6)
- MASKOR Institut für Mobile Autonome Systeme und Kognitive Robotik (5)
- Solar-Institut Jülich (5)
- Arbeitsstelle fuer Hochschuldidaktik und Studienberatung (1)
- IBB - Institut für Baustoffe und Baukonstruktionen (1)
Study of swift heavy ion modified conduction polymer composites for application as gas sensor
(2006)
A polyaniline-based conducting composite was prepared by oxidative polymerisation of aniline in a polyvinylchloride (PVC) matrix. The coherent free standing thin films of the composite were prepared by a solution casting method. The polyvinyl chloride-polyaniline composites exposed to 120 MeV ions of silicon with total ion fluence ranging from 1011 to 1013 ions/cm2, were observed to be more sensitive towards ammonia gas than the unirradiated composite. The response time of the irradiated composites was observed to be comparably shorter. We report for the first time the application of swift heavy ion modified insulating polymer conducting polymer (IPCP) composites for sensing of ammonia gas.
Impressum | Inhalt 03
Thomas Tünnemann | Unterwegs...am Wege 04
Projekte 06
Annelie Wirtz | Arrivato 08
Sebastian Rupp | Tracce Passate 18
Henri Boh | Terrazze sopra il lago 28
Hermann Stuzmann | L´Ammissione è Gratuita 32
Vivienne Scheidz | IL Potere dei Simboli 34
Felix Keller | Strada Infinita 38
Moran Dorner | Catturato nel Posto 42
Kevin Osterkamp | Vortice 46
Kristina Foidle | La Vespa e il Fico 52
Simon Rix | Sognare Sulla Strada 58
Jennifer Sikora | Strada Pietrosa 66
Sabrina Frömbgen | Bolla di Pensiero 72
Miriam Azzab | Il Momento 78
Georg Mörke | Sentiero stretto 84
Saskia Frömbgen | Nuova Prospetiva 90
Frank Drehsen | A grado a grado 96
Caronlin Grün | Le prospettive 100
Thomas Tünnemann | Flusso nella Foresta 104
Atmosphärisches
Auf die Küche | Kulinarisches 114
Carpe Diem | Fotografisches 116
WS GTaD-2003 - The 1st Workshop on Graph Transformations and Design ed Grabska, E., Seite 6-7, Jagiellonian University Krakow. 2 pages
In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff’s base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective.