Refine
Year of publication
Document Type
- Article (426)
- Conference Proceeding (113)
- Part of a Book (37)
- Doctoral Thesis (20)
- Report (10)
- Book (8)
- Other (3)
- Habilitation (2)
- Patent (2)
- Review (1)
- Talk (1)
Has Fulltext
- no (623) (remove)
Keywords
- solar sail (5)
- CellDrum (3)
- GOSSAMER-1 (3)
- MASCOT (3)
- Biocomposites (2)
- Iterative learning control (2)
- Limit analysis (2)
- Mars (2)
- Natural fibres (2)
- Polymer-matrix composites (2)
- Shakedown analysis (2)
- Solar sail (2)
- Spacecraft (2)
- Stiffness (2)
- Stress concentrations (2)
- Trajectory Optimization (2)
- bacterial cellulose (2)
- biopotential electrodes (2)
- damage (2)
- locomotion (2)
- multiple NEA rendezvous (2)
- muscle fascicle behavior (2)
- prebiotic (2)
- small spacecraft (2)
- ultrasound (2)
- ultrasound imaging (2)
- Achilles tendon (1)
- Adaptive control (1)
- Ageing (1)
- AlterG (1)
- Alzheimer's disease (1)
- Anastomotic leakage (1)
- Anatomy (1)
- Annulus Fibrosus (1)
- Antarctic Glaciology (1)
- Antarctica (1)
- Architectural gear ratio (1)
- Assistive technology (1)
- Asteroid Deflection (1)
- Attitude dynamics (1)
- Autolysis (1)
- Automated Optimization (1)
- Automatic control (1)
- Bacillus sp (1)
- Biomechanical simulation (1)
- Biosolubilization (1)
- Bladder (1)
- Bone sawing (1)
- Cardiac myocytes (1)
- Cardiac tissue (1)
- Cell permeability (1)
- Cellular force (1)
- Cementoblast (1)
- Chance constrained programming (1)
- Circular Dichroism (1)
- Coefficient of ocular rigidity (1)
- Collagen fibrils (1)
- Compression (1)
- Computational biomechanics (1)
- Connective tissues (1)
- Constitutive model (1)
- Contractile tension (1)
- Corneo-scleral shell (1)
- DLR-ESTEC GOSSAMER roadmap for solar sailing (1)
- Damage mechanics theory (1)
- Decomposition (1)
- Differential tonometry (1)
- Disc Degeneration (1)
- Discontinuous fractures (1)
- Distorsion des oberen Sprunggelenks (1)
- Drug simulation (1)
- Dry surfaces (1)
- EEG (1)
- ES-FEM (1)
- Electromechanical modeling (1)
- End-to-end colorectal anastomosis (1)
- Endothelial cells (1)
- Endothelial dysfunction (1)
- Evolution of damage (1)
- Evolutionary Neurocontrol (1)
- Extension fracture (1)
- Extension strain criterion (1)
- External knee adduction moments (1)
- Extracellular matrix (ECM) (1)
- Extraterrestrial Glaciology (1)
- Eyeball (1)
- FGF23 (1)
- FS-FEM (1)
- Finite element analysis (1)
- Finite element analysis (FEA) (1)
- Finite element modelling (1)
- Force (1)
- Forces (1)
- Fracture configuration (1)
- Fracture simulation (1)
- Freeze–thaw process (1)
- Frequency adaption (1)
- Glaciological instruments and methods (1)
- Glaucoma (1)
- Gossamer (1)
- Gossamer structures (1)
- Growth modelling (1)
- Haemodialysis (1)
- Handbike (1)
- Heart tissue culture (1)
- Hodgkin–Huxley models (1)
- Homogenization (1)
- Human-Computer interaction (1)
- Hybrid Propellants (1)
- Ice melting probe (1)
- Ice penetration (1)
- Icy moons (1)
- Impedance Spectroscopy (1)
- Induced pluripotent stem cells (1)
- Inotropic compounds (1)
- Interplanetary flight (1)
- Interstellar objects (1)
- Intervertebral Disc (1)
- Intradiscal Pressure (1)
- Inverse dynamic problem (1)
- Inverse kinematic problem (1)
- Ion channels (1)
- Jupiter (1)
- Klotho (1)
- Knee (1)
- LPS (1)
- Lactobacillus rhamnosus GG (1)
- Lipopolysaccharide (1)
- Liver (1)
- Load modeling (1)
- Long COVID (1)
- Low-Thrust Propulsion (1)
- Machine learning (1)
- Manipulated variables (1)
- Mechanical simulation (1)
- Mechanical stability (1)
- Mechanotransduction (1)
- Microbial adhesion (1)
- Microcirculation (1)
- Mild cognitive impairment (1)
- Missions (1)
- Mohr–Coulomb criterion (1)
- Multimode failure (1)
- Multiphase (1)
- Muscle (1)
- Muscle Fascicle (1)
- Muscle Force (1)
- Muscle fibers (1)
- Musculoskeletal model (1)
- Musculoskeletal system (1)
- Myocardial infarction and cardiac death (1)
- NONOate (1)
- Niacin (1)
- Nitric Oxide (1)
- Nitric Oxide Donor (1)
- Non-linear optimization (1)
- Non-parallel fissures (1)
- Nucleus Pulposus (1)
- Ocean worlds (1)
- Ocular blood flow (1)
- Orbital dynamics (1)
- PHILAE (1)
- PTH (1)
- Paralympic sport (1)
- Passive stretching (1)
- Pelvic floor dysfunction (1)
- Pelvic muscle (1)
- Pharmacology (1)
- Phosphate (1)
- Physiology (1)
- Planetary Protection (1)
- Planetary exploration (1)
- Post-COVID-19 syndrome (1)
- Pressure-volume relationship (1)
- Proximal humerus fracture (1)
- Pulsations (1)
- RVA (1)
- Recombinant activated protein C (1)
- Reconstruction (1)
- Rehabilitation Technology and Prosthetics (1)
- Rehabilitation engineering (1)
- Reliability analysis (1)
- Reliability of structures (1)
- Retinal vessel analysis (1)
- Retinal vessels (1)
- Reusable Rocket Engines (1)
- Riboflavin (1)
- Robotic rehabilitation (1)
- Rotator cuff (1)
- Running (1)
- S-FEM (1)
- Sampling methods (1)
- Septic cardiomyopathy (1)
- Sequence-Search (1)
- Simulation (1)
- Sleep EEG (1)
- Small Solar System Body Lander (1)
- Small Spacecraft (1)
- Small spacecraft (1)
- Solar Power Sail (1)
- Solar Sail (1)
- Spacecraft Trajectory Optimization (1)
- Spleen (1)
- Sprunggelenkorthesen (1)
- Stochastic programming (1)
- Subclacial exploration (1)
- Subglacial lakes (1)
- SunRav BookEditor (1)
- Surface microorganisms (1)
- Surgical Navigation and Robotics (1)
- Surgical staplers (1)
- Swabbing (1)
- Tapered ends (1)
- Tendon Rupture (1)
- Tendon properties (1)
- Tension (1)
- Thiamine (1)
- Training (1)
- Trajectories (1)
- Uniaxial compression test (1)
- Ureter (1)
- Variable height stapler design (1)
- Vascular response (1)
- Vasomotions (1)
- Visual field asymmetry (1)
- Vitamin A (1)
- Vitamin B (1)
- Vitamin D (1)
- achilles tendon (1)
- actin cytoskeleton (1)
- adipose-derived stromal cells (ASCs) (1)
- adsorption (1)
- agility (1)
- anaesthetic complications (1)
- anisotropy (1)
- ankle braces (1)
- ankle sprain (1)
- aortic perfusion (1)
- asteroid lander (1)
- asteroid sample return (1)
- attitude dynamics (1)
- biaxial tensile experiment (1)
- biofilms (1)
- biomechanics (1)
- carbonized rice husk (1)
- cardiomyocyte biomechanics (1)
- cell aerosolization (1)
- cell atomization (1)
- cerebral small vessel disease (1)
- chance constrained programming (1)
- coculture (1)
- cognitive impairment (1)
- community dwelling (1)
- computational fluid dynamics analysis (1)
- connective tissue (1)
- constitutive modeling (1)
- constructive alignment (1)
- correlation (1)
- crop yield (1)
- dental trauma (1)
- dialysis (1)
- difficult airway (1)
- distance learning (1)
- distorted element (1)
- double-lumen tube intubation (1)
- drop jump (1)
- e-books (1)
- e-issues (1)
- electromyography (1)
- endoluminal (1)
- energy absorption (1)
- energy dissipation (1)
- examination (1)
- exopolysaccharides (1)
- extracorporeal membrane oxygenation (1)
- fibulare Bandruptur (1)
- flotilla missions (1)
- force generation (1)
- forehead EEG (1)
- gait (1)
- habitability (1)
- healthy aging (1)
- heliosphere (1)
- hiPS cardiomyocytes (1)
- high-intensity exercise (1)
- humic acid (1)
- hyper-gravity (1)
- hyperelastic (1)
- hypo-gravity (1)
- ice moons (1)
- icy moons (1)
- immobilization (1)
- impedance spectroscopy (1)
- in-ear EEG (1)
- intraclass correlation coefficient (1)
- ion propulsion (1)
- life detection (1)
- lignite (1)
- limit analysis (1)
- lipopolysaccharide (1)
- long-term retention (1)
- low-rank coal (1)
- low-thrust (1)
- low-thrust trajectory optimization (1)
- mechanical buffer (1)
- multimodal (1)
- muscle mechanics (1)
- near-Earth asteroid (1)
- non-simplex S-FEM elements (1)
- orbit control (1)
- orbital dynamics (1)
- overload (1)
- parabolic flight (1)
- performance testing (1)
- physiology (1)
- planetary defence (1)
- practical learning (1)
- prevention (1)
- psychosocial (1)
- pullulan (1)
- rehabilitation (1)
- reliability of structures (1)
- responsive space (1)
- retinal microvasculature (1)
- retinal vessels (1)
- running (1)
- rupture of the fibular ligament (1)
- sEMG (1)
- sailcraft (1)
- sample return (1)
- sarcomere operating length (1)
- sensors (1)
- series elastic element behavior (1)
- shakedown analysis (1)
- shoulder (1)
- simulation (1)
- small solar system body characterisation (1)
- small spacecraft asteroid lander (1)
- small spacecraft solar sail (1)
- smooth muscle contraction (1)
- softs (1)
- soil amendment (1)
- soil health (1)
- soil remediation (1)
- solar sails (1)
- solar system (1)
- space missions (1)
- sprint start (1)
- standard error of measurement (1)
- stiffness (1)
- stochastic programming (1)
- strain energy function (1)
- stretch reflex (1)
- stretch-shortening cycle (1)
- surface modification (1)
- survival (1)
- system engineering (1)
- tendon rupture (1)
- test-retest reliability (1)
- training simulator (1)
- tri-lineage differentiation (1)
- twin-fluid atomizer (1)
- ultrasonography (1)
- underwater vehicle (1)
- unloading (1)
- videolaryngoscopy (1)
- virgin passive (1)
- virtual reality (1)
- viscoelasticity (1)
- walking (1)
- walking gait (1)
Institute
- IfB - Institut für Bioengineering (623) (remove)
Impaired cerebral autoregulation and neurovascular coupling (NVC) contribute to delayed cerebral ischemia after subarachnoid hemorrhage (SAH). Retinal vessel analysis (RVA) allows non-invasive assessment of vessel dimension and NVC hereby demonstrating a predictive value in the context of various neurovascular diseases. Using RVA as a translational approach, we aimed to assess the retinal vessels in patients with SAH. RVA was performed prospectively in 24 patients with acute SAH (group A: day 5–14), in 11 patients 3 months after ictus (group B: day 90 ± 35), and in 35 age-matched healthy controls (group C). Data was acquired using a Retinal Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and NVC using flicker-light excitation. Diameter of retinal vessels—central retinal arteriolar and venular equivalent—was significantly reduced in the acute phase (p < 0.001) with gradual improvement in group B (p < 0.05). Arterial NVC of group A was significantly impaired with diminished dilatation (p < 0.001) and reduced area under the curve (p < 0.01) when compared to group C. Group B showed persistent prolonged latency of arterial dilation (p < 0.05). Venous NVC was significantly delayed after SAH compared to group C (A p < 0.001; B p < 0.05). To our knowledge, this is the first clinical study to document retinal vasoconstriction and impairment of NVC in patients with SAH. Using non-invasive RVA as a translational approach, characteristic patterns of compromise were detected for the arterial and venous compartment of the neurovascular unit in a time-dependent fashion. Recruitment will continue to facilitate a correlation analysis with clinical course and outcome.
Edge-based and face-based smoothed finite element methods (ES-FEM and FS-FEM, respectively) are modified versions of the finite element method allowing to achieve more accurate results and to reduce sensitivity to mesh distortion, at least for linear elements. These properties make the two methods very attractive. However, their implementation in a standard finite element code is nontrivial because it requires heavy and extensive modifications to the code architecture. In this article, we present an element-based formulation of ES-FEM and FS-FEM methods allowing to implement the two methods in a standard finite element code with no modifications to its architecture. Moreover, the element-based formulation permits to easily manage any type of element, especially in 3D models where, to the best of the authors' knowledge, only tetrahedral elements are used in FS-FEM applications found in the literature. Shape functions for non-simplex 3D elements are proposed in order to apply FS-FEM to any standard finite element.
Purpose
In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model.
Material and Methods
Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio).
Results
In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF.
Conclusion
The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018.
Orthodontic treatments are concomitant with mechanical forces and thereby cause teeth movements. The applied forces are transmitted to the tooth root and the periodontal ligaments which is compressed on one side and tensed up on the other side. Indeed, strong forces can lead to tooth root resorption and the crown-to-tooth ratio is reduced with the potential for significant clinical impact. The cementum, which covers the tooth root, is a thin mineralized tissue of the periodontium that connects the periodontal ligament with the tooth and is build up by cementoblasts. The impact of tension and compression on these cells is investigated in several in vivo and in vitro studies demonstrating differences in protein expression and signaling pathways. In summary, osteogenic marker changes indicate that cyclic tensile forces support whereas static tension inhibits cementogenesis. Furthermore, cementogenesis experiences the same protein expression changes in static conditions as static tension, but cyclic compression leads to the exact opposite of cyclic tension. Consistent with marker expression changes, the singaling pathways of Wnt/ß-catenin and RANKL/OPG show that tissue compression leads to cementum degradation and tension forces to cementogenesis. However, the cementum, and in particular its cementoblasts, remain a research area which should be explored in more detail to understand the underlying mechanism of bone resorption and remodeling after orthodontic treatments.
A laser-enhanced solar sail is a solar sail that is not solely propelled by solar radiation but additionally by a laser beam that illuminates the sail. This way, the propulsive acceleration of the sail results from the combined action of the solar and the laser radiation pressure onto the sail. The potential source of the laser beam is a laser satellite that coverts solar power (in the inner solar system) or nuclear power (in the outer solar system) into laser power. Such a laser satellite (or many of them) can orbit anywhere in the solar system and its optimal orbit (or their optimal orbits) for a given mission is a subject for future research. This contribution provides the model for an ideal laser-enhanced solar sail and investigates how a laser can enhance the thrusting capability of such a sail. The term ”ideal” means that the solar sail is assumed to be perfectly reflecting and that the laser beam is assumed to have a constant areal power density over the whole sail area. Since a laser beam has a limited divergence, it can provide radiation pressure at much larger solar distances and increase the radiation pressure force into the desired direction. Therefore, laser-enhanced solar sails may make missions feasible, that would otherwise have prohibitively long flight times, e.g. rendezvous missions in the outer solar system. This contribution will also analyze exemplary mission scenarios and present optimial trajectories without laying too much emphasis on the design and operations of the laser satellites. If the mission studies conclude that laser-enhanced solar sails would have advantages with respect to ”traditional” solar sails, a detailed study of the laser satellites and the whole system architecture would be the second next step
Thrombogenic complications are a main issue in mechanical circulatory support (MCS). There is no validated in vitro method available to quantitatively assess the thrombogenic performance of pulsatile MCS devices under realistic hemodynamic conditions. The aim of this study is to propose a method to evaluate the thrombogenic potential of new designs without the use of complex in-vivo trials. This study presents a novel in vitro method for reproducible thrombogenicity testing of pulsatile MCS systems using low molecular weight heparinized porcine blood. Blood parameters are continuously measured with full blood thromboelastometry (ROTEM; EXTEM, FIBTEM and a custom-made analysis HEPNATEM). Thrombus formation is optically observed after four hours of testing. The results of three experiments are presented each with two parallel loops. The area of thrombus formation inside the MCS device was reproducible. The implantation of a filter inside the loop catches embolizing thrombi without a measurable increase of platelet activation, allowing conclusions of the place of origin of thrombi inside the device. EXTEM and FIBTEM parameters such as clotting velocity (α) and maximum clot firmness (MCF) show a total decrease by around 6% with a characteristic kink after 180 minutes. HEPNATEM α and MCF rise within the first 180 minutes indicate a continuously increasing activation level of coagulation. After 180 minutes, the consumption of clotting factors prevails, resulting in a decrease of α and MCF. With the designed mock loop and the presented protocol we are able to identify thrombogenic hot spots inside a pulsatile pump and characterize their thrombogenic potential.
Solar sails provide ignificant advantages over other low-thrust propulsion systems because they produce thrust by the momentum exchange from solar radiation pressure (SRP) and thus do not consume any propellant.The force exerted on a very thin sail foil basically depends on the light incidence angle. Several analytical SRP force models that describe the SRP force acting on the sail have been established since the 1970s. All the widely used models use constant optical force coefficients of the reflecting sail material. In 2006,MENGALI et al. proposed a refined SRP force model that takes into account the dependancy of the force coefficients on the light incident angle,the sail’s distance from the sun (and thus the sail emperature) and the surface roughness of the sail material [1]. In this paper, the refined SRP force model is compared to the previous ones in order to identify the potential impact of the new model on the predicted capabilities of solar sails in performing low-cost interplanetary space missions. All force models have been implemented within InTrance, a global low-thrust trajectory optimization software utilizing evolutionary neurocontrol [2]. Two interplanetary rendezvous missions, to Mercury and the near-Earth asteroid 1996FG3, are investigated. Two solar sail performances in terms of characteristic acceleration are examined for both scenarios, 0.2 mm/s2 and 0.5 mm/s2, termed “low” and “medium” sail performance. In case of the refined SRP model, three different values of surface roughness are chosen, h = 0 nm, 10 nm and 25 nm. The results show that the refined SRP force model yields shorter transfer times than the standard model.
We present a new approach to the problem of optimal control of solar sails for low-thrust trajectory optimization. The objective was to find the required control torque magnitudes in order to steer a solar sail in interplanetary space. A new steering strategy, controlling the solar sail with generic torques applied about the spacecraft body axes, is integrated into the existing low-thrust trajectory optimization software InTrance. This software combines artificial neural networks and evolutionary algorithms to find steering strategies close to the global optimum without an initial guess. Furthermore, we implement a three rotational degree-of-freedom rigid-body attitude dynamics model to represent the solar sail in space. Two interplanetary transfers to Mars and Neptune are chosen to represent typical future solar sail mission scenarios. The results found with the new steering strategy are compared to the existing reference trajectories without attitude dynamics. The resulting control torques required to accomplish the missions are investigated, as they pose the primary requirements to a real on-board attitude control system.
Clearance of blood components and fluid drainage play a crucial role in subarachnoid hemorrhage (SAH) and post hemorrhagic hydrocephalus (PHH). With the involvement of interstitial fluid (ISF) and cerebrospinal fluid (CSF), two pathways for the clearance of fluid and solutes in the brain are proposed. Starting at the level of capillaries, flow of ISF follows along the basement membranes in the walls of cerebral arteries out of the parenchyma to drain into the lymphatics and CSF [1]–[3]. Conversely, it is shown that CSF enters the parenchyma between glial and pial basement membranes of penetrating arteries [4]–[6]. Nevertheless, the involved structures and the contribution of either flow pathway to fluid balance between the subarachnoid space and interstitial space remains controversial. Low frequency oscillations in vascular tone are referred to as vasomotion and corresponding vasomotion waves are modeled as the driving force for flow of ISF out of the parenchyma [7]. Retinal vessel analysis (RVA) allows non-invasive measurement of retinal vessel vasomotion with respect to diameter changes [8]. Thus, the aim of the study is to investigate vasomotion in RVA signals of SAH and PHH patients.
The MYOTONES experiment is the first to monitor changes in the basic biomechanical properties (tone, elasticity and stiffness) of the resting human myofascial system due to microgravity with a oninvasive, portable device on board the ISS. The MyotonPRO device applies several brief mechanical stimuli to the surface of the skin, and the natural oscillation signals of the tissue beneath are detected and computed by the MyotonPRO. Thus, an objective, quick and easy determination of the state of the underlying tissue is possible.
Two preflight, four inflight and four post flight measurements were performed on a male astronaut using the same 10 measurement points (MP) for each session. MPs were located on the plantar fascia, Achilles tendon, M. soleus, M. gastrocnemius, M. multifidus, M. splenius capitis, M. deltoideus anterior, M. rectus femoris, infrapatellar tendon, M. tibialis anterior. Subcutaneous tissues thickness above the MPs was measured using ultrasound imaging. Magnetic resonance images (MRI) of lower limb muscles and functional tests were also performed pre- and postflight.
Our first measurements on board the ISS confirmed increased tone and stiffness of the lumbar multifidus muscle, an important trunk stabilizer, dysfunction of which is known to be associated with back pain. Furthermore, reduced tone and stiffness of Achilles tendon and plantar fascia were observed inflight vs. preflight, confirming previous findings from terrestrial analog studies and parabolic
flights. Unexpectedly, the deltoid showed negative inflight changes in tone and stiffness, and increased elasticity, suggesting a potential risk of muscle atrophy in longer spaceflight that should be addressed by adequate inflight countermeasure protocols. Most values from limb and back MPS showed deflected patterns (in either directions) from inflight shortly after the re-entry phase on the landing day and one week later. Most parameter values then normalized to baseline after 3 weeks likely due to 1G re-adaptation and possible outcome of the reconditioning protocol. No major changes in subcutaneous tissues thickness above the MPs were found inflight vs preflight, suggesting no bias (i.e., fluid shift, extreme tissue thickening or loss). Pre- and postflight MRI and functional tests showed negligible changes in calf muscle size, power and force, which is likely due to training effects from current inflight exercise protocols.
The MYOTONES experiment is currently ongoing to collect data from further crew members. The potential impact of this research is to better understand the effects of microgravity and countermeasures over the time course of an ISS mission cycle. This will enable exercise countermeasures to be tailored
Using the OpenSim software and verified anatomical data, a computer model for the calculation of biomechanical parameters is developed and used to determine the effect of a reattachment of the Supraspinatus muscle with a medial displacement of the muscle attachment point, which may be necessary for a rupture of the supraspinatus tendon. The results include the influence of the operation on basic biomechanical parameters such as the lever arm, as well as the calculated the muscle activations for the supraspinatus and deltoid. In addition, the influence on joint stability is examined by an analysis of the joint reaction force. The study provides a detailed description of the used model, as well as medical findings to a reattachment of the supraspinatus.
Mit der Software OpenSim und überprüften anatomischen Daten wird ein Computermodell zur Berechnung von biomechanischen Parametern entwickelt und genutzt, um den Effekt einer Refixierung des Supraspinatusmuskels mit einer medialen Verschiebung des Muskelansatzpunktes zu ermitteln, wie sie unter anderem nach einem Riss der Supraspinatussehne notwendig sein kann. Die Ergebnisse umfassen hierbei den Einfluss der Operation auf grundlegende biomechanische Parameter wie den Hebelarm sowie die berechneten Muskelaktivierungen für den Supraspinatus und Deltoideus. Zusätzlich wird der Einfluss auf die Gelenkstabilität betrachtet und durch eine Analyse der Gelenkreaktionskraft untersucht. Die Studie bietet eine detaillierte Beschreibung des genutzten Modells, sowie medizinische Erkenntnisse zu einer Refixierung des Supraspinatus.